{"id":10556,"date":"2026-06-29T08:40:02","date_gmt":"2026-06-29T08:40:02","guid":{"rendered":"https:\/\/ntgdvalve.com\/?p=10556"},"modified":"2026-06-29T09:26:47","modified_gmt":"2026-06-29T09:26:47","slug":"ball-valve-standards","status":"publish","type":"post","link":"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/","title":{"rendered":"Normas para v\u00e1lvulas de bola: API 6D, API 608, ASME B16.34, ISO 17292 y requisitos de prueba"},"content":{"rendered":"<p><strong>Author Name:<\/strong> Bruce Zheng<\/p>\n<p><strong>Author Role:<\/strong> Co-Founder and Valve Engineer at NTGD Valve<\/p>\n<p><strong>Author Bio:<\/strong> Bruce Zheng is Co-Founder and Valve Engineer at NTGD Valve, focusing on industrial valve selection, application, and technical content for global B2B buyers.<\/p>\n<p><strong>Last Updated:<\/strong> June 29, 2026<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #0a0a0a;color:#0a0a0a\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #0a0a0a;color:#0a0a0a\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Quick_Answer_What_Ball_Valve_Standards_Should_Buyers_Check\" >Quick Answer: What Ball Valve Standards Should Buyers Check?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_Do_Ball_Valve_Standards_Actually_Cover\" >What Do Ball Valve Standards Actually Cover?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Standards_vs_Codes_vs_Project_Specifications\" >Standards vs Codes vs Project Specifications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Why_a_Standard_Name_Alone_Is_Not_Enough_in_an_RFQ\" >Why a Standard Name Alone Is Not Enough in an RFQ<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Common_Ball_Valve_Standards_Comparison_Table\" >Common Ball Valve Standards Comparison Table<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#API_608_Ball_Valve_Standard\" >API 608 Ball Valve Standard<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_API_608_Covers\" >What API 608 Covers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#API_608_and_ASME_B1634_Relationship\" >API 608 and ASME B16.34 Relationship<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#When_API_608_Is_Not_Enough_by_Itself\" >When API 608 Is Not Enough by Itself<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#API_6D_Ball_Valve_Pipeline-Service_Boundary\" >API 6D Ball Valve: Pipeline-Service Boundary<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_API_6D_Means_in_a_Ball_Valve_Standards_Map\" >What API 6D Means in a Ball Valve Standards Map<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#API_608_vs_API_6D_in_One_View\" >API 608 vs API 6D in One View<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#When_to_Review_a_Dedicated_API_6D_Ball_Valve_Guide\" >When to Review a Dedicated API 6D Ball Valve Guide<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#ASME_B1634_and_ISO_17292_in_Ball_Valve_Specifications\" >ASME B16.34 and ISO 17292 in Ball Valve Specifications<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#ASME_B1634_Pressure-Temperature_and_Construction_Basis\" >ASME B16.34: Pressure-Temperature and Construction Basis<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#ISO_17292_International_Metal_Ball_Valve_Standard\" >ISO 17292: International Metal Ball Valve Standard<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#How_These_Standards_Work_with_API_608_or_API_6D\" >How These Standards Work with API 608 or API 6D<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Ball_Valve_Testing_Standards_API_598_Shell_Test_Seat_Test_and_Test_Reports\" >Ball Valve Testing Standards: API 598, Shell Test, Seat Test and Test Reports<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#API_598_as_an_Inspection_and_Testing_Standard\" >API 598 as an Inspection and Testing Standard<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Shell_Test_and_Seat_Closure_Test\" >Shell Test and Seat \/ Closure Test<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Test_Reports_MTC_and_Inspection_Records\" >Test Reports, MTC and Inspection Records<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#How_to_Choose_the_Right_Ball_Valve_Standard_for_an_RFQ\" >How to Choose the Right Ball Valve Standard for an RFQ<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Ball_Valve_RFQ_Standards_Checklist\" >Ball Valve RFQ Standards Checklist<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Common_Mistakes_When_Specifying_Ball_Valve_Standards\" >Common Mistakes When Specifying Ball Valve Standards<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Writing_%E2%80%9CAPI_Compliant%E2%80%9D_Without_Naming_the_Standard\" >Writing \u201cAPI Compliant\u201d Without Naming the Standard<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Using_API_6D_When_the_Service_Is_Not_Pipeline-Related\" >Using API 6D When the Service Is Not Pipeline-Related<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Treating_API_598_as_a_Design_Standard\" >Treating API 598 as a Design Standard<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Assuming_API_608_Automatically_Means_Fire-Safe\" >Assuming API 608 Automatically Means Fire-Safe<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Selecting_Only_by_Pressure_Class\" >Selecting Only by Pressure Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Confusing_Standard_Port_with_Ball_Valve_Standards\" >Confusing Standard Port with Ball Valve Standards<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Requesting_a_PDF_Instead_of_a_Project_Specification\" >Requesting a PDF Instead of a Project Specification<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#FAQ\" >FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_is_the_standard_for_ball_valves\" >What is the standard for ball valves?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_is_API_608_for_ball_valves\" >What is API 608 for ball valves?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_is_the_difference_between_API_608_and_API_6D\" >What is the difference between API 608 and API 6D?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-36\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_is_the_difference_between_API_608_and_ASME_B1634\" >What is the difference between API 608 and ASME B16.34?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-37\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Is_ASME_B1634_a_ball_valve_standard\" >Is ASME B16.34 a ball valve standard?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-38\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_is_ISO_17292_for_ball_valves\" >What is ISO 17292 for ball valves?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-39\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_is_the_difference_between_ISO_17292_and_API_6D\" >What is the difference between ISO 17292 and API 6D?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-40\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_standard_covers_ball_valve_testing\" >What standard covers ball valve testing?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-41\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Is_API_598_the_same_as_API_6D\" >Is API 598 the same as API 6D?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-42\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Is_API_608_the_same_as_API_607\" >Is API 608 the same as API 607?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-43\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Can_a_ball_valve_comply_with_more_than_one_standard\" >Can a ball valve comply with more than one standard?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-44\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#What_should_I_include_in_a_ball_valve_RFQ\" >What should I include in a ball valve RFQ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-45\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Is_standard_port_ball_valve_the_same_as_ball_valve_standard\" >Is standard port ball valve the same as ball valve standard?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-46\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Conclusion\" >Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-47\" href=\"https:\/\/ntgdvalve.com\/es\/ball-valve-standards\/#Application_Specification_Support\" >Application \/ Specification Support<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Quick_Answer_What_Ball_Valve_Standards_Should_Buyers_Check\"><\/span>Quick Answer: What Ball Valve Standards Should Buyers Check?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"attachment_10576\" aria-describedby=\"caption-attachment-10576\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-10576\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-map-rfq-data-.png\" alt=\"Ball valve standards map showing API 608, API 6D, ASME B16.34, ISO 17292 and API 598 connected to an industrial ball valve.\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-map-rfq-data-.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-map-rfq-data--768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-map-rfq-data--1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-map-rfq-data--18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-map-rfq-data--600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-10576\" class=\"wp-caption-text\">Ball valve standards should be matched to RFQ data, not selected by standard name alone.<\/figcaption><\/figure>\n<p>Ball valve standards are not a single rule that applies to every project. In industrial purchasing, the correct standard depends on the valve application, pressure class, body material, end connection, bore type, testing requirement, documentation requirement and project specification.<\/p>\n<p>For many metal ball valve RFQs, buyers commonly see several standards used together. <strong>API 608<\/strong> is often referenced for metal ball valves used in process and industrial services. <strong>API 6D<\/strong> applies to pipeline-service valves and is not a default specification for every ball valve. <strong>ASME B16.34<\/strong> supports pressure-temperature rating, materials and construction requirements for valves with flanged, threaded and welding ends. <strong>ISO 17292<\/strong> is an international metal ball valve standard used in petroleum, petrochemical, natural gas plant and related industrial applications. <strong>API 598<\/strong> is used for finished-valve inspection and testing, including shell and seat \/ closure testing.<\/p>\n<p>Choosing the wrong standard combination can affect cost, lead time and technical acceptance. Specifying API 6D for a non-pipeline process valve may add unnecessary documentation and project requirements, while ignoring the relationship between pressure class, material and service temperature can create pressure-temperature rating mismatches.<\/p>\n<p>A good RFQ should not simply say \u201cstandard ball valve\u201d or \u201cAPI compliant.\u201d It should state the required valve standard, pressure class, size, material, end connection, seat \/ seal material, service medium, design temperature, design pressure, testing standard and required documents such as test reports, MTCs and inspection records.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_Do_Ball_Valve_Standards_Actually_Cover\"><\/span>What Do Ball Valve Standards Actually Cover?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A ball valve standard may define or influence several different parts of a valve specification. Some standards focus on valve design and construction. Some support pressure-temperature ratings or material selection. Some focus on finished-valve inspection and testing. Others are special-service requirements, such as fire-safe testing or sour service material control.<\/p>\n<p>For this reason, buyers should treat ball valve standards as a specification system, not as a single label.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Standards_vs_Codes_vs_Project_Specifications\"><\/span>Standards vs Codes vs Project Specifications<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A standard usually defines technical requirements for a product, test, material or design scope. A piping code may define requirements for the broader piping system, such as system-level piping rules that valve specifications must align with. A project specification or datasheet then tells the supplier which standard, material, pressure class, testing requirement and documentation package apply to a specific order.<\/p>\n<p>For example, a ball valve may be specified with a ball valve standard, a pressure-temperature basis, a testing standard and a project datasheet at the same time. These are not interchangeable. One document may define the valve construction, another may define testing, and another may define what the project owner wants to receive before shipment.<\/p>\n<p>The project specification or datasheet is the final purchasing carrier that turns multiple standards into executable procurement requirements. Without it, even a correctly named standard can still lead to manufacturing, inspection or documentation differences.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Why_a_Standard_Name_Alone_Is_Not_Enough_in_an_RFQ\"><\/span>Why a Standard Name Alone Is Not Enough in an RFQ<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A standard name alone does not fully define the valve. Two ball valves referencing the same standard can still be technically different in several RFQ-critical dimensions:<\/p>\n<ul>\n<li>size and pressure class;<\/li>\n<li>full bore or reduced bore design;<\/li>\n<li>floating or trunnion-mounted construction;<\/li>\n<li>flanged, threaded, socket weld or butt weld ends;<\/li>\n<li>carbon steel, stainless steel or alloy material;<\/li>\n<li>soft seat or metal seat design;<\/li>\n<li>manual, gear, pneumatic, electric or hydraulic operation;<\/li>\n<li>fire-safe, anti-static, fugitive emission or sour service requirements;<\/li>\n<li>inspection, testing and document package.<\/li>\n<\/ul>\n<p>For RFQ work, the standard gives the technical framework. The datasheet gives the project-specific details.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Common_Ball_Valve_Standards_Comparison_Table\"><\/span>Common Ball Valve Standards Comparison Table<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The table below gives a practical standards map for buyers preparing a ball valve RFQ. Use it to understand each standard\u2019s role before deciding what must appear in the project datasheet.<\/p>\n<figure id=\"attachment_10579\" aria-describedby=\"caption-attachment-10579\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-10579\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-role-map-1.png\" alt=\"Ball valve standards role map showing API 608, API 6D, ASME B16.34, ISO 17292 and API 598.\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-role-map-1.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-role-map-1-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-role-map-1-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-role-map-1-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-standards-role-map-1-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-10579\" class=\"wp-caption-text\">Each ball valve standard has a different role in design, service scope, ratings, testing or RFQ documentation.<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>Standard \/ Requirement<\/th>\n<th>Main Role<\/th>\n<th>Applies To \/ Common Context<\/th>\n<th>What It Does Not Replace<\/th>\n<th>RFQ Note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>API 608<\/td>\n<td>Metal ball valve design and construction reference<\/td>\n<td>Process, petroleum, petrochemical and industrial metal ball valves<\/td>\n<td>Does not replace all pipeline-service requirements or project datasheets<\/td>\n<td>Use when specifying metal ball valves for applicable industrial service; confirm end connection, bore type, pressure class and material<\/td>\n<\/tr>\n<tr>\n<td>API 6D<\/td>\n<td>Pipeline \/ piping valve specification<\/td>\n<td>Pipeline service, long-distance transmission and pipeline isolation<\/td>\n<td>Should be reserved for pipeline-service requirements and not used as a default specification for general industrial process valves<\/td>\n<td>Confirm pipeline service, acceptance rules and project documentation requirements before specifying API 6D<\/td>\n<\/tr>\n<tr>\n<td>ASME B16.34<\/td>\n<td>Pressure-temperature, material, construction and marking basis for valves<\/td>\n<td>Flanged, threaded and welding-end valves in ASME-related piping systems<\/td>\n<td>Does not replace a ball-valve-specific design standard by itself<\/td>\n<td>Confirm pressure class, material group, design temperature and end connection<\/td>\n<\/tr>\n<tr>\n<td>ISO 17292<\/td>\n<td>International metal ball valve standard<\/td>\n<td>Petroleum, petrochemical, natural gas plant and related industrial applications<\/td>\n<td>Does not replace every API 6D pipeline-service requirement<\/td>\n<td>Useful when the project references ISO-based metal ball valve specifications<\/td>\n<\/tr>\n<tr>\n<td>API 598<\/td>\n<td>Inspection and pressure testing standard<\/td>\n<td>Finished-valve inspection, shell test, seat \/ closure test and leakage acceptance<\/td>\n<td>Does not define the full ball valve design<\/td>\n<td>Specify the testing standard and required test report in the RFQ<\/td>\n<\/tr>\n<tr>\n<td>API 607 \/ ISO 10497<\/td>\n<td>Fire-safe testing requirement<\/td>\n<td>Fire-safe ball valve applications where fire exposure performance must be verified<\/td>\n<td>Does not mean every API 608 valve is automatically fire-safe<\/td>\n<td>Ask for fire-safe certificate only when required by the project<\/td>\n<\/tr>\n<tr>\n<td>NACE \/ ISO 15156<\/td>\n<td>Sour service \/ material requirement<\/td>\n<td>H\u2082S or sour service where material cracking risk must be controlled<\/td>\n<td>Does not replace ball valve design or pressure testing standards<\/td>\n<td>Confirm medium, H\u2082S content and material requirements before quotation<\/td>\n<\/tr>\n<tr>\n<td>ISO 5208 \/ EN 12266<\/td>\n<td>International valve testing references<\/td>\n<td>International valve pressure testing and leakage acceptance contexts<\/td>\n<td>Does not automatically replace the project-specified test standard<\/td>\n<td>Use only when required by the project specification or regional standard package<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This table is a quick map, not a substitute for the official standards or the project datasheet. The actual RFQ still needs to be checked against service condition, project specification, material, temperature, pressure class, testing documents and required inspection records.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"API_608_Ball_Valve_Standard\"><\/span>API 608 Ball Valve Standard<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>API 608 is one of the most common standards buyers ask about when specifying industrial metal ball valves. In a ball valve standards map, API 608 is important because it is directly connected with metal ball valve construction and typical industrial valve requirements.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_API_608_Covers\"><\/span>What API 608 Covers<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For RFQ purposes, API 608 is commonly associated with metal ball valves, including requirements related to design, end connections, bore type, stem retention, anti-static features and other construction details depending on the valve design and project requirement.<\/p>\n<p>To verify the official standard scope before finalizing a project specification, check the <a href=\"https:\/\/www.apiwebstore.org\/standards\/608?edition=6\" target=\"_blank\" rel=\"noopener\">API 608 standard page<\/a> rather than relying on a catalog title alone.<\/p>\n<p>Buyers often reference API 608 for flanged, threaded or welding-end ball valves used in petroleum, petrochemical and industrial service. The exact applicability still needs to be checked against the valve size, pressure class, end connection, body material, seat material and project standard list.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"API_608_and_ASME_B1634_Relationship\"><\/span>API 608 and ASME B16.34 Relationship<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 608 and ASME B16.34 often appear together in industrial ball valve specifications. They do not serve the same function.<\/p>\n<p>API 608 is more directly connected with metal ball valve requirements. ASME B16.34 supports the broader valve pressure-temperature, material and construction basis. In many RFQs, the buyer may need both the ball valve standard and the pressure-temperature \/ construction basis to make the specification complete.<\/p>\n<p>A practical RFQ should therefore avoid a vague sentence such as \u201cAPI 608 ball valve required\u201d without class, material, temperature and end connection. The standard name is only one part of the specification.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_API_608_Is_Not_Enough_by_Itself\"><\/span>When API 608 Is Not Enough by Itself<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 608 does not replace every other project requirement on its own. For many process metal ball valve RFQs, API 608 may be the correct starting point, but the buyer still needs to confirm ASME B16.34 pressure-temperature basis, testing standard, seat \/ seal material, fire-safe requirement, sour service requirement and documentation package.<\/p>\n<p>For pipeline-service ball valves, the project may require API 6D instead of relying only on API 608. For fire-safe service, API 607 or ISO 10497 may need to be specified separately. For H\u2082S or sour service, NACE \/ ISO 15156 requirements may need to be checked. For inspection records, the RFQ should clearly state the testing standard and document package.<\/p>\n<p>API 608 is a strong design reference for metal ball valves, but it is not a complete project specification by itself.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"API_6D_Ball_Valve_Pipeline-Service_Boundary\"><\/span>API 6D Ball Valve: Pipeline-Service Boundary<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>API 6D is important in the ball valve standards conversation, but it belongs to a specific service context. It is not a default specification for general-purpose ball valves.<\/p>\n<p>API\u2019s publication announcement for <a href=\"https:\/\/www.api.org\/~\/media\/files\/publications\/whats%20new\/6d_e24%20pa.pdf\" target=\"_blank\" rel=\"noopener\">API Specification 6D<\/a> identifies it as a pipeline and piping valve specification covering ball, check, gate and plug valves, which is why this article treats it as a pipeline-service boundary rather than a general ball-valve default.<\/p>\n<figure id=\"attachment_10577\" aria-describedby=\"caption-attachment-10577\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-10577\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-vs-api-6d-ball-valve-standards-comparison-1.png\" alt=\"API 608 vs API 6D comparison board showing metal ball valves and pipeline valves.\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-vs-api-6d-ball-valve-standards-comparison-1.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-vs-api-6d-ball-valve-standards-comparison-1-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-vs-api-6d-ball-valve-standards-comparison-1-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-vs-api-6d-ball-valve-standards-comparison-1-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-vs-api-6d-ball-valve-standards-comparison-1-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-10577\" class=\"wp-caption-text\">API 608 and API 6D serve different specification contexts, so service type should be checked before RFQ.<\/figcaption><\/figure>\n<p>In a standards map, API 6D belongs to pipeline-service valves. It is commonly used when the valve is part of a pipeline system where pipeline isolation, documentation, pressure testing and service conditions require a pipeline valve specification. It also covers more than ball valves, so it is broader than a ball-valve-only standard.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_API_6D_Means_in_a_Ball_Valve_Standards_Map\"><\/span>What API 6D Means in a Ball Valve Standards Map<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>An API 6D ball valve is usually associated with pipeline service. The project may involve oil, gas or other pipeline media, and the valve may require specific documentation, pressure testing and traceability expectations.<\/p>\n<p>For a general process ball valve, API 608 together with ASME B16.34 may be more relevant than specifying API 6D by default. For a pipeline-service ball valve, API 6D may be a critical project requirement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"API_608_vs_API_6D_in_One_View\"><\/span>API 608 vs API 6D in One View<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Comparison Point<\/th>\n<th>API 608<\/th>\n<th>API 6D<\/th>\n<th>Buyer Note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Main focus<\/td>\n<td>Metal ball valves<\/td>\n<td>Pipeline \/ piping valves<\/td>\n<td>Start with service type before selecting the standard<\/td>\n<\/tr>\n<tr>\n<td>Common use<\/td>\n<td>Industrial process and related service<\/td>\n<td>Pipeline service<\/td>\n<td>For non-pipeline process service, do not specify API 6D by default<\/td>\n<\/tr>\n<tr>\n<td>Valve scope<\/td>\n<td>Ball valves<\/td>\n<td>Multiple pipeline valve types, including ball valves<\/td>\n<td>API 6D is broader than a ball-valve-only standard<\/td>\n<\/tr>\n<tr>\n<td>RFQ risk<\/td>\n<td>Missing class, material, testing or fire-safe requirement<\/td>\n<td>Over-specifying API 6D for non-pipeline service<\/td>\n<td>API 608 + ASME B16.34 may be more relevant for many process metal ball valve RFQs<\/td>\n<\/tr>\n<tr>\n<td>Documentation<\/td>\n<td>Depends on project and inspection requirements<\/td>\n<td>Often tied to stronger project documentation expectations<\/td>\n<td>For pipeline projects, confirm API 6D documentation, test report, MTC and inspection records<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure id=\"attachment_10578\" aria-describedby=\"caption-attachment-10578\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10578\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-api-6d-pipeline-service-boundary-diagram-1.png\" alt=\"API 608 and API 6D pipeline-service boundary diagram for ball valve standard selection.\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-api-6d-pipeline-service-boundary-diagram-1.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-api-6d-pipeline-service-boundary-diagram-1-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-api-6d-pipeline-service-boundary-diagram-1-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-api-6d-pipeline-service-boundary-diagram-1-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/api-608-api-6d-pipeline-service-boundary-diagram-1-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-10578\" class=\"wp-caption-text\">API 608 is commonly used for process metal ball valves, while API 6D is tied to pipeline-service requirements.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"When_to_Review_a_Dedicated_API_6D_Ball_Valve_Guide\"><\/span>When to Review a Dedicated API 6D Ball Valve Guide<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A dedicated API 6D ball valve guide is more appropriate when the project involves pipeline service, long-distance transmission, pipeline isolation, project documentation packages or specific pipeline valve acceptance requirements.<\/p>\n<p>In this article, API 6D is only explained as part of the overall standards map. Detailed API 6D ball valve construction, testing, documentation, DBB \/ DIB, pipeline project acceptance and RFQ preparation should remain with a dedicated API 6D ball valve guide, not this general ball valve standards guide.<\/p>\n<p>For deeper construction, testing, documentation and RFQ details, review NTGD\u2019s <a href=\"https:\/\/ntgdvalve.com\/api-6d-ball-valve\/\">API 6D ball valve guide<\/a> instead of expanding those pipeline-specific details in this standards overview.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"ASME_B1634_and_ISO_17292_in_Ball_Valve_Specifications\"><\/span>ASME B16.34 and ISO 17292 in Ball Valve Specifications<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>ASME B16.34 and ISO 17292 both appear in ball valve specifications, but they play different roles. They help complete the standards map, but neither should turn this article into a full ASME or ISO standard commentary.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"ASME_B1634_Pressure-Temperature_and_Construction_Basis\"><\/span>ASME B16.34: Pressure-Temperature and Construction Basis<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ASME B16.34 is not a ball-valve-only standard. In ball valve specifications, it is commonly relevant to pressure-temperature ratings, materials, construction, dimensions, tolerances, marking and related valve requirements for flanged, threaded and welding-end valves.<\/p>\n<p>ASME\u2019s official <a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-34-valves-flanged-threaded-welding-end\" target=\"_blank\" rel=\"noopener\">B16.34 standard page<\/a> should be used when confirming the pressure-temperature, material, testing and marking basis referenced by the project specification.<\/p>\n<p>For a buyer, the most important point is that a pressure class alone is not enough. Under the same pressure class, different body materials and service temperatures can lead to different allowable pressure-temperature limits, so class, material and temperature must be checked together.<\/p>\n<p>A Class 150, Class 300 or Class 600 valve still needs material, temperature, end connection and seat \/ seal information before the supplier can confirm suitability. ASME B16.34 should be considered together with the ball valve standard, the piping code, the project datasheet and any testing or special-service requirements.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"ISO_17292_International_Metal_Ball_Valve_Standard\"><\/span>ISO 17292: International Metal Ball Valve Standard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ISO 17292 is an international standard for metal ball valves used in petroleum, petrochemical, natural gas plant and related industrial applications. It is useful when the project specification follows ISO-based standards or when the buyer wants an international metal ball valve standard instead of an API-centered specification set.<\/p>\n<p>For ISO-based projects, verify the scope against the official <a href=\"https:\/\/www.iso.org\/standard\/59736.html\" target=\"_blank\" rel=\"noopener\">ISO 17292:2015 standard page<\/a>, which identifies the standard as covering metal ball valves for petroleum, petrochemical, natural gas plant and related industrial applications.<\/p>\n<p>In practice, ISO 17292 may appear with requirements related to end connections, bore type, materials, testing and inspection. It does not replace pipeline-specific requirements on its own, and it does not remove the need for project-specific pressure class, material, service temperature, seat \/ seal and testing information.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_These_Standards_Work_with_API_608_or_API_6D\"><\/span>How These Standards Work with API 608 or API 6D<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A project may reference API 608 or ISO 17292 for metal ball valve construction, ASME B16.34 for pressure-temperature and construction basis, API 598 for inspection and testing, and additional requirements for fire-safe or sour service.<\/p>\n<p>ISO 17292 is a metal ball valve product standard, while API 6D is a pipeline-service valve specification. They may overlap in some projects, but one should not be treated as a direct replacement for the other.<\/p>\n<p>The correct combination depends on the project specification. A clear RFQ should tell the supplier which standard is mandatory, which standard is optional, which standard is used for testing, and which documents must be supplied after inspection.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Ball_Valve_Testing_Standards_API_598_Shell_Test_Seat_Test_and_Test_Reports\"><\/span>Ball Valve Testing Standards: API 598, Shell Test, Seat Test and Test Reports<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A ball valve testing standard answers a different question from a design standard. API 598 works at the finished-valve inspection and testing level, not as the design basis for selecting the ball valve itself.<\/p>\n<p>API 598 is commonly associated with valve inspection and pressure testing. It helps define how finished valves are inspected and tested, including shell testing and seat \/ closure testing. It works alongside the design standard and project datasheet; it does not replace API 608, API 6D, ASME B16.34 or ISO 17292.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"API_598_as_an_Inspection_and_Testing_Standard\"><\/span>API 598 as an Inspection and Testing Standard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For buyers, API 598 is important because it connects the RFQ to finished-valve test expectations. If the project requires pressure test records, leakage acceptance confirmation or inspection documentation, the RFQ should state the testing standard and the documents required before shipment.<\/p>\n<p>For third-party confirmation of API 598 scope, the <a href=\"https:\/\/store.accuristech.com\/standards\/api-std-598?product_id=2523432\" target=\"_blank\" rel=\"noopener\">API Std 598 standard page<\/a> can be used to verify that it addresses valve inspection, examination, supplementary examinations and pressure test requirements.<\/p>\n<p>A vague statement such as \u201cvalve must be tested\u201d is not enough. The supplier needs to know the test standard, inspection scope, report format and whether third-party inspection is required.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Shell_Test_and_Seat_Closure_Test\"><\/span>Shell Test and Seat \/ Closure Test<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>In general terms, a shell test checks the pressure-containing boundary of the valve body and related pressure-retaining parts. A seat or closure test checks sealing performance across the closed valve seats. The exact test pressure, duration, medium and acceptance criteria must be verified against the applicable standard, valve design and project specification.<\/p>\n<p>Buyers should not request informal pressure testing without defining what test evidence they need. A test report is often more useful than a simple statement that the valve has been tested.<\/p>\n<figure id=\"attachment_10575\" aria-describedby=\"caption-attachment-10575\" style=\"width: 1517px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10575\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/18-inch-600lb-a105n-ball-valve-pressure-testing.png\" alt=\"18 inch 600LB A105N ball valve during factory pressure testing.\" width=\"1517\" height=\"935\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/18-inch-600lb-a105n-ball-valve-pressure-testing.png 1517w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/18-inch-600lb-a105n-ball-valve-pressure-testing-768x473.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/18-inch-600lb-a105n-ball-valve-pressure-testing-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/18-inch-600lb-a105n-ball-valve-pressure-testing-600x370.png 600w\" sizes=\"(max-width: 1517px) 100vw, 1517px\" \/><figcaption id=\"caption-attachment-10575\" class=\"wp-caption-text\">18-inch 600LB A105N ball valve during factory pressure testing.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Test_Reports_MTC_and_Inspection_Records\"><\/span>Test Reports, MTC and Inspection Records<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Test \/ Document<\/th>\n<th>What It Checks or Supports<\/th>\n<th>Buyer Should Request<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Shell test<\/td>\n<td>Pressure boundary integrity of the valve body and pressure-retaining parts<\/td>\n<td>Shell test report according to the specified test standard<\/td>\n<\/tr>\n<tr>\n<td>Seat \/ closure test<\/td>\n<td>Sealing performance of the closed valve<\/td>\n<td>Seat \/ closure test report with test medium and result<\/td>\n<\/tr>\n<tr>\n<td>Visual and dimensional inspection<\/td>\n<td>General conformance to drawing, datasheet and manufacturing requirements<\/td>\n<td>Inspection record or final inspection report<\/td>\n<\/tr>\n<tr>\n<td>Material test certificate \/ MTC<\/td>\n<td>Material traceability and chemical \/ mechanical data<\/td>\n<td>MTC for pressure-retaining parts; specify certificate type, such as EN 10204 3.1, if the project or code requires material traceability<\/td>\n<\/tr>\n<tr>\n<td>Fire-safe certificate<\/td>\n<td>Fire exposure performance for specified designs<\/td>\n<td>Certificate only when fire-safe service is required<\/td>\n<\/tr>\n<tr>\n<td>Third-party inspection record<\/td>\n<td>Independent verification when required by project<\/td>\n<td>TPI release note or inspection witness record<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Testing requirements should be written in the RFQ and checked against the project datasheet before manufacturing and shipment. This article only covers the test-standard role and RFQ document requirements; detailed pressure test methods and execution procedures should be handled in a dedicated pressure testing guide.<\/p>\n<p>For step-by-step valve pressure testing practices by valve type, use NTGD\u2019s <a href=\"https:\/\/ntgdvalve.com\/pressure-test-methods-for-various-industrial-valves\/\">industrial valve pressure testing guide<\/a> instead of expanding the procedure in this standards overview.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Choose_the_Right_Ball_Valve_Standard_for_an_RFQ\"><\/span>How to Choose the Right Ball Valve Standard for an RFQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The easiest way to choose the right ball valve standard is to start with the service condition, not the standard name. Before quotation, confirm what the valve will do, where it will be installed, what medium it will handle, what pressure and temperature it will see, and what documentation the project owner requires.<\/p>\n<table>\n<thead>\n<tr>\n<th>Service \/ Requirement<\/th>\n<th>Standard to Check First<\/th>\n<th>Additional Notes<\/th>\n<th>RFQ Data Needed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>General industrial metal ball valve<\/td>\n<td>API 608 or ISO 17292<\/td>\n<td>Confirm whether the project follows API or ISO standard system; blindly specifying API 6D may add unnecessary cost, documentation and lead time<\/td>\n<td>Size, class \/ PN, material, end connection, bore, seat<\/td>\n<\/tr>\n<tr>\n<td>Pipeline service<\/td>\n<td>API 6D<\/td>\n<td>Use when the project requires pipeline valve specification; using only a general process valve standard may fail to meet pipeline documentation or acceptance expectations<\/td>\n<td>Pipeline service data, size, class, bore, operation, documentation<\/td>\n<\/tr>\n<tr>\n<td>Pressure-temperature rating<\/td>\n<td>ASME B16.34<\/td>\n<td>Check material and temperature together, not pressure class alone<\/td>\n<td>Body material, design temperature, pressure class<\/td>\n<\/tr>\n<tr>\n<td>Finished-valve pressure testing<\/td>\n<td>API 598 or project-specified testing standard<\/td>\n<td>Define reports and witness requirements; an unclear test standard may result in reports that do not match project acceptance<\/td>\n<td>Test standard, test report, inspection level<\/td>\n<\/tr>\n<tr>\n<td>Fire-safe service<\/td>\n<td>API 607 or ISO 10497<\/td>\n<td>Required only when the service or project specification demands it; if not stated separately, the supplier may quote a standard non-fire-safe configuration<\/td>\n<td>Fire-safe requirement, certificate, seat \/ seal design<\/td>\n<\/tr>\n<tr>\n<td>Sour service<\/td>\n<td>NACE \/ ISO 15156 or project requirement<\/td>\n<td>Material suitability must be verified for the service; if not stated separately, the quotation may follow ordinary service assumptions<\/td>\n<td>Medium composition, H\u2082S content, material requirement<\/td>\n<\/tr>\n<tr>\n<td>International metal ball valve specification<\/td>\n<td>ISO 17292<\/td>\n<td>Useful for ISO-based petroleum, petrochemical and gas plant requirements<\/td>\n<td>Standard edition, material, end connection, test requirement<\/td>\n<\/tr>\n<tr>\n<td>Project documentation package<\/td>\n<td>Project specification \/ datasheet<\/td>\n<td>Standards do not replace the datasheet; unclear document requirements can delay inspection and release<\/td>\n<td>MTC, test report, inspection record, tag data<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The RFQ should also state whether the buyer requires the latest edition of the standard, a specific edition, or compliance with the project owner\u2019s standard list.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Ball_Valve_RFQ_Standards_Checklist\"><\/span>Ball Valve RFQ Standards Checklist<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A complete RFQ reduces technical back-and-forth and helps the supplier confirm whether the requested ball valve can be offered under the required standards.<\/p>\n<figure id=\"attachment_10580\" aria-describedby=\"caption-attachment-10580\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10580\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-rfq-standards-checklist-1.png\" alt=\"Ball valve RFQ checklist showing standard, size, class, material, end connection, bore, operation, medium, testing and documents.\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-rfq-standards-checklist-1.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-rfq-standards-checklist-1-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-rfq-standards-checklist-1-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-rfq-standards-checklist-1-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/ball-valve-rfq-standards-checklist-1-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-10580\" class=\"wp-caption-text\">A complete ball valve RFQ should include standards, service data, testing requirements and documents before quotation.<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>RFQ Field<\/th>\n<th>Why It Matters<\/th>\n<th>Example Input Needed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Required valve standard<\/td>\n<td>Defines the main technical framework<\/td>\n<td>API 608, API 6D, ISO 17292 or project standard<\/td>\n<\/tr>\n<tr>\n<td>Standard edition<\/td>\n<td>Avoids mismatch between buyer and supplier expectations<\/td>\n<td>Latest edition or project-specified edition<\/td>\n<\/tr>\n<tr>\n<td>Valve type<\/td>\n<td>Clarifies floating, trunnion, two-piece, three-piece or other design<\/td>\n<td>Floating ball valve, trunnion-mounted ball valve, 2-piece body, 3-piece body<\/td>\n<\/tr>\n<tr>\n<td>Size<\/td>\n<td>Defines valve nominal size<\/td>\n<td>NPS 2, DN50, NPS 6, DN150<\/td>\n<\/tr>\n<tr>\n<td>Pressure class \/ PN<\/td>\n<td>Defines pressure rating system<\/td>\n<td>Class 150 \/ 300 \/ 600, PN16 \/ PN25 \/ PN40<\/td>\n<\/tr>\n<tr>\n<td>Body material<\/td>\n<td>Affects pressure-temperature rating and corrosion suitability<\/td>\n<td>ASTM A216 WCB, ASTM A351 CF8M, ASTM A105, ASTM A182 F316<\/td>\n<\/tr>\n<tr>\n<td>Trim \/ seat \/ seal material<\/td>\n<td>Affects sealing, temperature and media compatibility<\/td>\n<td>PTFE, RPTFE, PEEK, metal seat, graphite<\/td>\n<\/tr>\n<tr>\n<td>End connection<\/td>\n<td>Affects piping compatibility<\/td>\n<td>ASME B16.5 RF flange, RTJ, NPT, SW, BW<\/td>\n<\/tr>\n<tr>\n<td>Bore type<\/td>\n<td>Affects flow, pigging and pressure drop<\/td>\n<td>Full bore or reduced bore<\/td>\n<\/tr>\n<tr>\n<td>Operation<\/td>\n<td>Affects torque, automation and installation space<\/td>\n<td>Lever, gear, pneumatic, electric, hydraulic<\/td>\n<\/tr>\n<tr>\n<td>Medium<\/td>\n<td>Affects material, seat and special requirements<\/td>\n<td>Water, oil, gas, steam, chemical, sour gas<\/td>\n<\/tr>\n<tr>\n<td>Design temperature<\/td>\n<td>Affects material and seat selection<\/td>\n<td>Minimum and maximum design temperature<\/td>\n<\/tr>\n<tr>\n<td>Design pressure<\/td>\n<td>Confirms pressure condition beyond nominal class<\/td>\n<td>Operating pressure and design pressure<\/td>\n<\/tr>\n<tr>\n<td>Testing standard<\/td>\n<td>Defines pressure test and inspection basis<\/td>\n<td>API 598 or project-specified test standard<\/td>\n<\/tr>\n<tr>\n<td>Test report<\/td>\n<td>Provides evidence of finished-valve testing<\/td>\n<td>Shell test + seat \/ closure test report according to the specified standard<\/td>\n<\/tr>\n<tr>\n<td>MTC \/ material certificate<\/td>\n<td>Supports material traceability<\/td>\n<td>EN 10204 3.1 or project-required certificate type if applicable<\/td>\n<\/tr>\n<tr>\n<td>Inspection record<\/td>\n<td>Supports final inspection and release<\/td>\n<td>Final inspection report, dimensional record or TPI record<\/td>\n<\/tr>\n<tr>\n<td>Fire-safe certificate<\/td>\n<td>Required only for fire-safe service<\/td>\n<td>API 607 \/ ISO 10497 certificate when specified<\/td>\n<\/tr>\n<tr>\n<td>NACE \/ sour service requirement<\/td>\n<td>Required for sour service material control<\/td>\n<td>NACE \/ ISO 15156 requirement if applicable<\/td>\n<\/tr>\n<tr>\n<td>Project specification \/ datasheet<\/td>\n<td>Resolves conflicts and special requirements<\/td>\n<td>Datasheet, tag list, project standard list<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>If sizing, port design, Cv or installation data is still incomplete, review NTGD\u2019s <a href=\"https:\/\/ntgdvalve.com\/how-to-properly-size-and-install-ball-valves-for-optimal-performance\/\">ball valve sizing and installation guide<\/a> before finalizing the RFQ.<\/p>\n<p>Attach the checklist to the RFQ before price comparison. Without these details, two quotations may look similar but represent different valve designs, testing levels and documentation packages.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Common_Mistakes_When_Specifying_Ball_Valve_Standards\"><\/span>Common Mistakes When Specifying Ball Valve Standards<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Writing_%E2%80%9CAPI_Compliant%E2%80%9D_Without_Naming_the_Standard\"><\/span>Writing \u201cAPI Compliant\u201d Without Naming the Standard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>\u201cAPI compliant\u201d is too vague. It does not tell the supplier whether the buyer means API 608, API 6D, API 598, API 607 or another API document. This can cause suppliers to quote on different technical assumptions, making price and delivery comparisons unreliable.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Using_API_6D_When_the_Service_Is_Not_Pipeline-Related\"><\/span>Using API 6D When the Service Is Not Pipeline-Related<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 6D is important for pipeline service, but it is not the default requirement for all industrial ball valves. Over-specifying API 6D may increase cost, lead time and documentation requirements without improving fit for a non-pipeline service.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Treating_API_598_as_a_Design_Standard\"><\/span>Treating API 598 as a Design Standard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 598 is related to inspection and pressure testing. It defines finished-valve testing expectations, not the valve design basis. If the RFQ only names API 598, the design standard may remain unclear.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Assuming_API_608_Automatically_Means_Fire-Safe\"><\/span>Assuming API 608 Automatically Means Fire-Safe<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 608 and fire-safe testing are different requirements. If fire-safe performance is required, the RFQ should clearly state the fire-safe standard or certificate requirement. Do not assume it is included unless the datasheet or quotation confirms it.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Selecting_Only_by_Pressure_Class\"><\/span>Selecting Only by Pressure Class<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A pressure class is not enough by itself. Material, temperature, seat design, end connection and service medium must also be checked. A valve that looks acceptable by class may not be suitable for the actual temperature, corrosion condition or sealing requirement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Confusing_Standard_Port_with_Ball_Valve_Standards\"><\/span>Confusing Standard Port with Ball Valve Standards<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A standard port ball valve refers to bore \/ port design. It is not the same as a ball valve standard. If the buyer needs to discuss full port versus standard port, that should be handled as a bore selection question, not as a standards \/ compliance question.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Requesting_a_PDF_Instead_of_a_Project_Specification\"><\/span>Requesting a PDF Instead of a Project Specification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A standard PDF is not a substitute for a project datasheet. The supplier needs the actual RFQ data: service, size, pressure class, material, end connection, testing standard, documentation and inspection requirements. Without those details, manufacturing and inspection documents may not match the project owner\u2019s acceptance requirements.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_standard_for_ball_valves\"><\/span>What is the standard for ball valves?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>There is no single standard for every ball valve. Commonly referenced standards include API 608 for metal ball valves, API 6D for pipeline-service valves, ASME B16.34 for pressure-temperature and construction basis, ISO 17292 for international metal ball valve specifications, and API 598 for inspection and testing.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_API_608_for_ball_valves\"><\/span>What is API 608 for ball valves?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 608 is commonly used for metal ball valves in petroleum, petrochemical and industrial applications. In an RFQ, it should be combined with details such as size, pressure class, material, end connection, bore type, seat material, testing standard and required documents.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_API_608_and_API_6D\"><\/span>What is the difference between API 608 and API 6D?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 608 is mainly associated with metal ball valves. API 6D is a pipeline \/ piping valve specification and covers more than ball valves. API 6D is typically used when the valve is for pipeline service, while API 608 is often used for industrial metal ball valves outside dedicated pipeline-service requirements.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_API_608_and_ASME_B1634\"><\/span>What is the difference between API 608 and ASME B16.34?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 608 is more directly related to metal ball valve requirements. ASME B16.34 supports pressure-temperature, material and construction basis for valves. They often work together in a complete specification, but they should not be treated as substitutes.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_ASME_B1634_a_ball_valve_standard\"><\/span>Is ASME B16.34 a ball valve standard?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ASME B16.34 is not a ball-valve-only standard. It is commonly used as a valve standard related to pressure-temperature ratings, materials, construction, dimensions, tolerances and marking for flanged, threaded and welding-end valves. It can support a ball valve specification, but it does not replace the need for a ball valve design standard or project datasheet.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_ISO_17292_for_ball_valves\"><\/span>What is ISO 17292 for ball valves?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ISO 17292 is an international standard for metal ball valves used in petroleum, petrochemical, natural gas plant and related industrial applications. It may be used when the project follows ISO-based specifications or requires an international metal ball valve standard.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_ISO_17292_and_API_6D\"><\/span>What is the difference between ISO 17292 and API 6D?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ISO 17292 is an international metal ball valve standard. API 6D is a pipeline-service valve specification. Their application scope is different, and one does not automatically replace the other.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_standard_covers_ball_valve_testing\"><\/span>What standard covers ball valve testing?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>API 598 is commonly referenced for valve inspection and pressure testing, including shell tests and seat \/ closure tests. The exact testing requirement should be stated in the RFQ and checked against the project specification.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_API_598_the_same_as_API_6D\"><\/span>Is API 598 the same as API 6D?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. API 598 is related to inspection and testing. API 6D is a pipeline \/ piping valve specification. A project may reference both, but they do not serve the same function.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_API_608_the_same_as_API_607\"><\/span>Is API 608 the same as API 607?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. API 608 is related to metal ball valve requirements. API 607 is related to fire-safe testing. If a project requires fire-safe performance, the RFQ should state the fire-safe requirement separately.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_a_ball_valve_comply_with_more_than_one_standard\"><\/span>Can a ball valve comply with more than one standard?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes, a ball valve can reference more than one standard if the design, testing and documentation support it. For example, an RFQ may reference a ball valve design standard, ASME B16.34 pressure-temperature basis, API 598 testing and a fire-safe or sour service requirement. The supplier should confirm compliance and provide the required documents.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_should_I_include_in_a_ball_valve_RFQ\"><\/span>What should I include in a ball valve RFQ?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A ball valve RFQ should include the required standard, standard edition, size, pressure class, material, end connection, bore type, seat \/ seal material, operation, medium, design temperature, design pressure, testing standard, test report, MTC, inspection requirement and any fire-safe or sour service requirement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_standard_port_ball_valve_the_same_as_ball_valve_standard\"><\/span>Is standard port ball valve the same as ball valve standard?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>No. A standard port ball valve refers to the bore size through the valve. A ball valve standard refers to a design, construction, pressure-temperature, testing or compliance requirement.<\/p>\n<p>For bore selection details, the separate NTGD guide on <a href=\"https:\/\/ntgdvalve.com\/advantages-of-full-port-ball-valves-over-standard-port-ball-valves\/\">standard port vs full port ball valves<\/a> explains this as a port-design issue, not a compliance-standard issue.<\/p>\n<p>If a buyer writes \u201cstandard port\u201d when they actually mean a design or compliance standard such as API 608, the supplier may interpret the request as a bore-size requirement instead of a standard requirement. This can lead to quotations that do not match the intended valve specification.<\/p>\n<p><script type=\"application\/ld+json\"> { \"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [ { \"@type\": \"Question\", \"name\": \"What is the standard for ball valves?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"There is no single standard for every ball valve. Commonly referenced standards include API 608 for metal ball valves, API 6D for pipeline-service valves, ASME B16.34 for pressure-temperature and construction basis, ISO 17292 for international metal ball valve specifications, and API 598 for inspection and testing.\" } }, { \"@type\": \"Question\", \"name\": \"What is API 608 for ball valves?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"API 608 is commonly used for metal ball valves in petroleum, petrochemical and industrial applications. In an RFQ, it should be combined with details such as size, pressure class, material, end connection, bore type, seat material, testing standard and required documents.\" } }, { \"@type\": \"Question\", \"name\": \"What is the difference between API 608 and API 6D?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"API 608 is mainly associated with metal ball valves. API 6D is a pipeline or piping valve specification and covers more than ball valves. API 6D is typically used when the valve is for pipeline service, while API 608 is often used for industrial metal ball valves outside dedicated pipeline-service requirements.\" } }, { \"@type\": \"Question\", \"name\": \"What is the difference between API 608 and ASME B16.34?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"API 608 is more directly related to metal ball valve requirements. ASME B16.34 supports pressure-temperature, material and construction basis for valves. They often work together in a complete specification, but they should not be treated as substitutes.\" } }, { \"@type\": \"Question\", \"name\": \"Is ASME B16.34 a ball valve standard?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"ASME B16.34 is not a ball-valve-only standard. It is commonly used as a valve standard related to pressure-temperature ratings, materials, construction, dimensions, tolerances and marking for flanged, threaded and welding-end valves. It can support a ball valve specification, but it does not replace the need for a ball valve design standard or project datasheet.\" } }, { \"@type\": \"Question\", \"name\": \"What is ISO 17292 for ball valves?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"ISO 17292 is an international standard for metal ball valves used in petroleum, petrochemical, natural gas plant and related industrial applications. It may be used when the project follows ISO-based specifications or requires an international metal ball valve standard.\" } }, { \"@type\": \"Question\", \"name\": \"What is the difference between ISO 17292 and API 6D?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"ISO 17292 is an international metal ball valve standard. API 6D is a pipeline-service valve specification. Their application scope is different, and one does not automatically replace the other.\" } }, { \"@type\": \"Question\", \"name\": \"What standard covers ball valve testing?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"API 598 is commonly referenced for valve inspection and pressure testing, including shell tests and seat or closure tests. The exact testing requirement should be stated in the RFQ and checked against the project specification.\" } }, { \"@type\": \"Question\", \"name\": \"Is API 598 the same as API 6D?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"No. API 598 is related to inspection and testing. API 6D is a pipeline or piping valve specification. A project may reference both, but they do not serve the same function.\" } }, { \"@type\": \"Question\", \"name\": \"Is API 608 the same as API 607?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"No. API 608 is related to metal ball valve requirements. API 607 is related to fire-safe testing. If a project requires fire-safe performance, the RFQ should state the fire-safe requirement separately.\" } }, { \"@type\": \"Question\", \"name\": \"Can a ball valve comply with more than one standard?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Yes, a ball valve can reference more than one standard if the design, testing and documentation support it. For example, an RFQ may reference a ball valve design standard, ASME B16.34 pressure-temperature basis, API 598 testing and a fire-safe or sour service requirement. The supplier should confirm compliance and provide the required documents.\" } }, { \"@type\": \"Question\", \"name\": \"What should I include in a ball valve RFQ?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"A ball valve RFQ should include the required standard, standard edition, size, pressure class, material, end connection, bore type, seat or seal material, operation, medium, design temperature, design pressure, testing standard, test report, MTC, inspection requirement and any fire-safe or sour service requirement.\" } }, { \"@type\": \"Question\", \"name\": \"Is standard port ball valve the same as ball valve standard?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"No. A standard port ball valve refers to the bore size through the valve. A ball valve standard refers to a design, construction, pressure-temperature, testing or compliance requirement. If a buyer writes standard port when they actually mean a design or compliance standard such as API 608, the supplier may interpret the request as a bore-size requirement instead of a standard requirement. This can lead to quotations that do not match the intended valve specification.\" } } ] } <\/script><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ball valve standards should be selected as a specification system, not as a single label. API 608, API 6D, ASME B16.34, ISO 17292 and API 598 each answer different questions in the valve selection and RFQ process.<\/p>\n<p>API 608 is important for metal ball valves. API 6D should be reserved for pipeline-service requirements. ASME B16.34 helps define pressure-temperature and construction basis. ISO 17292 supports international metal ball valve specifications. API 598 supports finished-valve inspection and testing.<\/p>\n<p>Before ordering, confirm the required standard, pressure class, material, end connection, seat \/ seal material, service medium, design pressure, design temperature, testing standard and document package.<\/p>\n<figure id=\"attachment_10574\" aria-describedby=\"caption-attachment-10574\" style=\"width: 1461px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-10574\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/industrial-trunnion-ball-valve-workshop-photo.png\" alt=\"Real industrial trunnion ball valve in a workshop for ball valve specification review.\" width=\"1461\" height=\"936\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/industrial-trunnion-ball-valve-workshop-photo.png 1461w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/industrial-trunnion-ball-valve-workshop-photo-768x492.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/industrial-trunnion-ball-valve-workshop-photo-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/06\/industrial-trunnion-ball-valve-workshop-photo-600x384.png 600w\" sizes=\"(max-width: 1461px) 100vw, 1461px\" \/><figcaption id=\"caption-attachment-10574\" class=\"wp-caption-text\">Real industrial ball valve photo supporting the specification review and RFQ context.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Application_Specification_Support\"><\/span>Application \/ Specification Support<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"ntgd-cta-box\">\n<p>If you are not sure which ball valve standards should be listed in your RFQ, prepare the valve datasheet, service data and project standard list before quotation. NTGD Valve can review the specified standards, material, pressure class, testing level and documentation package to help confirm whether they fit the intended service.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Una gu\u00eda pr\u00e1ctica sobre las normas para v\u00e1lvulas de bola, que incluye las pruebas seg\u00fan las normas API 608, API 6D, ASME B16.34, ISO 17292 y API 598. Incluye tablas comparativas y una lista de verificaci\u00f3n para solicitudes de cotizaci\u00f3n dirigida a compradores industriales.<\/p>","protected":false},"author":1,"featured_media":10576,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_eb_attr":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[45],"tags":[],"class_list":["post-10556","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/posts\/10556","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/comments?post=10556"}],"version-history":[{"count":3,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/posts\/10556\/revisions"}],"predecessor-version":[{"id":10581,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/posts\/10556\/revisions\/10581"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/media\/10576"}],"wp:attachment":[{"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/media?parent=10556"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/categories?post=10556"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ntgdvalve.com\/es\/wp-json\/wp\/v2\/tags?post=10556"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}