{"id":9783,"date":"2026-05-26T06:33:14","date_gmt":"2026-05-26T06:33:14","guid":{"rendered":"https:\/\/ntgdvalve.com\/?p=9783"},"modified":"2026-05-26T06:33:32","modified_gmt":"2026-05-26T06:33:32","slug":"check-valve-selection-guide","status":"publish","type":"post","link":"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/","title":{"rendered":"Guide de s\u00e9lection des clapets anti-retour : Types, sens d'\u00e9coulement, perte de charge et adaptation \u00e0 l'application"},"content":{"rendered":"<p><strong>Author Name:<\/strong> Bruce Zheng<\/p>\n<p><strong>Author Role:<\/strong> Co-Founder and Valve Engineer at NTGD Valve<\/p>\n<p><strong>Author Bio:<\/strong> Bruce Zheng is Co-Founder and Valve Engineer at NTGD Valve, focusing on industrial valve selection, application, and technical content for global B2B buyers.<\/p>\n<p><strong>Last Updated:<\/strong> May 25, 2026<\/p>\n<p>Choosing a check valve is not only a matter of matching the pipe size. A proper check valve selection guide should start with the system conditions: media, flow rate, pressure, temperature, installation direction, pressure drop allowance, and the risk of reverse flow or water hammer.<\/p>\n<p>In industrial piping, the wrong check valve can create high head loss, unstable disc movement, chatter, seat wear, leakage, or slam during pump shutdown. The right valve is the one whose body design, closing behavior, material, seat, and installation orientation match the way the system actually operates.<\/p>\n<p>This guide explains how to choose a check valve by valve type, flow direction, pressure drop, cracking pressure, installation orientation, closing response, and application fit. It also includes selection tables and an RFQ checklist to help engineers and buyers prepare clearer specifications before ordering.<\/p>\n<figure id=\"attachment_9796\" aria-describedby=\"caption-attachment-9796\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-9796\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-path-media-flow-rfq.png\" alt=\"Check valve selection path from media and flow to valve type, installation and RFQ data\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-path-media-flow-rfq.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-path-media-flow-rfq-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-path-media-flow-rfq-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-path-media-flow-rfq-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-path-media-flow-rfq-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9796\" class=\"wp-caption-text\">A practical check valve selection path starts with service behavior and ends with RFQ data confirmation.<\/figcaption><\/figure>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #0a0a0a;color:#0a0a0a\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #0a0a0a;color:#0a0a0a\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Quick_Answer_How_to_Choose_a_Check_Valve\" >Quick Answer: How to Choose a Check Valve<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Start_With_Service_Conditions_Not_Pipe_Size_Alone\" >Start With Service Conditions, Not Pipe Size Alone<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#A_Practical_5-Step_Check_Valve_Selection_Path\" >A Practical 5-Step Check Valve Selection Path<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#When_a_Selection_Chart_Is_Helpful%E2%80%94and_When_It_Is_Not_Enough\" >When a Selection Chart Is Helpful\u2014and When It Is Not Enough<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_a_Check_Valve_Selection_Guide_Should_Decide\" >What a Check Valve Selection Guide Should Decide<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_a_Check_Valve_Does_in_an_Industrial_System\" >What a Check Valve Does in an Industrial System<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Check_Valve_vs_Non-Return_Valve_Terminology_Boundary\" >Check Valve vs Non-Return Valve: Terminology Boundary<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_This_Guide_Does_Not_Replace\" >What This Guide Does Not Replace<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Common_Check_Valve_Types_in_Selection_Context\" >Common Check Valve Types in Selection Context<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Swing_Check_Valves\" >Swing Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Lift_and_Piston_Check_Valves\" >Lift and Piston Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Ball_Check_Valves\" >Ball Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Dual_Plate_and_Wafer_Check_Valves\" >Dual Plate and Wafer Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Nozzle_Silent_and_Spring-Loaded_Check_Valves\" >Nozzle, Silent and Spring-Loaded Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Tilting_Disc_and_Special-Service_Check_Valves\" >Tilting Disc and Special-Service Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Check_Valve_Type_vs_Application_Fit_Table\" >Check Valve Type vs Application Fit Table<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Check_Valve_Selection_Criteria_Matrix\" >Check Valve Selection Criteria Matrix<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Media_and_Fluid_Compatibility\" >Media and Fluid Compatibility<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Flow_Rate_Flow_Velocity_and_Minimum_Flow\" >Flow Rate, Flow Velocity and Minimum Flow<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Operating_Pressure_Temperature_and_Pressure_Class\" >Operating Pressure, Temperature and Pressure Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Material_Seat_and_Seal_Compatibility\" >Material, Seat and Seal Compatibility<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Cracking_Pressure_and_Opening_Conditions\" >Cracking Pressure and Opening Conditions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Maintenance_Access_and_Lifecycle_Considerations\" >Maintenance Access and Lifecycle Considerations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Check_Valve_Selection_Criteria_Matrix-2\" >Check Valve Selection Criteria Matrix<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Flow_Rate_Pressure_Drop_and_Head_Loss\" >Flow Rate, Pressure Drop and Head Loss<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Why_Check_Valves_Should_Be_Sized_by_Flow_Conditions\" >Why Check Valves Should Be Sized by Flow Conditions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#How_Pressure_Drop_Affects_System_Performance\" >How Pressure Drop Affects System Performance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Cv_Kv_Head_Loss_and_Flow_Resistance_in_Practical_Selection\" >Cv \/ Kv, Head Loss and Flow Resistance in Practical Selection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Low_Pressure_Drop_Does_Not_Automatically_Mean_Best_Selection\" >Low Pressure Drop Does Not Automatically Mean Best Selection<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Flow_Direction_Body_Arrow_and_Installation_Orientation\" >Flow Direction, Body Arrow and Installation Orientation<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Why_Flow_Direction_Matters_for_Check_Valve_Selection\" >Why Flow Direction Matters for Check Valve Selection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Horizontal_vs_Vertical_Installation\" >Horizontal vs Vertical Installation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Pump_Discharge_Elbows_and_Unstable_Flow_Areas\" >Pump Discharge, Elbows and Unstable Flow Areas<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#When_Installation_Conditions_Require_Datasheet_Confirmation\" >When Installation Conditions Require Datasheet Confirmation<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Closing_Response_Water_Hammer_and_Non-Slam_Requirements\" >Closing Response, Water Hammer and Non-Slam Requirements<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-36\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Why_Check_Valve_Closing_Speed_Matters\" >Why Check Valve Closing Speed Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-37\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Slam_Reverse_Flow_and_Water_Hammer_Risk\" >Slam, Reverse Flow and Water Hammer Risk<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-38\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#When_to_Consider_Spring-Loaded_Silent_or_Nozzle_Check_Valves\" >When to Consider Spring-Loaded, Silent or Nozzle Check Valves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-39\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#How_Cracking_Pressure_Relates_to_Closing_and_Opening_Behavior\" >How Cracking Pressure Relates to Closing and Opening Behavior<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-40\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Check_Valve_Selection_Chart_by_Application_Fit\" >Check Valve Selection Chart by Application Fit<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-41\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#How_to_Use_This_Check_Valve_Selection_Chart\" >How to Use This Check Valve Selection Chart<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-42\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Application_Conditions_That_Usually_Drive_Valve_Choice\" >Application Conditions That Usually Drive Valve Choice<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-43\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#When_the_Chart_Should_Trigger_Engineering_Review\" >When the Chart Should Trigger Engineering Review<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-44\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Common_Wrong_Selection_Risks\" >Common Wrong Selection Risks<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-45\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#High_Pressure_Drop_or_Energy_Loss\" >High Pressure Drop or Energy Loss<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-46\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Chatter_Flutter_or_Incomplete_Opening\" >Chatter, Flutter or Incomplete Opening<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-47\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Slam_and_Water_Hammer\" >Slam and Water Hammer<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-48\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Fouling_Solids_Blockage_or_Sticking\" >Fouling, Solids Blockage or Sticking<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-49\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Leakage_Seat_Wear_and_Maintenance_Problems\" >Leakage, Seat Wear and Maintenance Problems<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-50\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Wrong_Selection_Risk_Matrix\" >Wrong Selection Risk Matrix<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-51\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Final_RFQ_and_Datasheet_Checklist_Before_Ordering\" >Final RFQ and Datasheet Checklist Before Ordering<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-52\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#System_Data_to_Confirm_Before_Selecting_a_Check_Valve\" >System Data to Confirm Before Selecting a Check Valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-53\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Valve_Data_to_Confirm_Before_RFQ\" >Valve Data to Confirm Before RFQ<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-54\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#When_to_Ask_for_Application_Review\" >When to Ask for Application Review<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-55\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Final_RFQ_Datasheet_Checklist\" >Final RFQ \/ Datasheet Checklist<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-56\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#FAQ_About_Check_Valve_Selection\" >FAQ About Check Valve Selection<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-57\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_is_the_most_common_mistake_in_check_valve_selection\" >What is the most common mistake in check valve selection?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-58\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_are_the_main_check_valve_selection_criteria\" >What are the main check valve selection criteria?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-59\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_is_a_check_valve_selection_chart\" >What is a check valve selection chart?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-60\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Should_a_check_valve_be_selected_by_pipe_size_or_flow_conditions\" >Should a check valve be selected by pipe size or flow conditions?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-61\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Which_check_valve_has_the_lowest_pressure_drop\" >Which check valve has the lowest pressure drop?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-62\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Can_a_check_valve_be_installed_vertically\" >Can a check valve be installed vertically?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-63\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#How_does_flow_direction_affect_check_valve_selection\" >How does flow direction affect check valve selection?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-64\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_is_cracking_pressure_in_a_check_valve\" >What is cracking pressure in a check valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-65\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#When_should_you_choose_a_spring-loaded_or_non-slam_check_valve\" >When should you choose a spring-loaded or non-slam check valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-66\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#What_information_should_be_provided_before_requesting_a_check_valve_quote\" >What information should be provided before requesting a check valve quote?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-67\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Conclusion_Select_the_Check_Valve_by_System_Behavior_Not_by_Name_Alone\" >Conclusion: Select the Check Valve by System Behavior, Not by Name Alone<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-68\" href=\"https:\/\/ntgdvalve.com\/fr\/check-valve-selection-guide\/#Application_Specification_Support\" >Application \/ Specification Support<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Quick_Answer_How_to_Choose_a_Check_Valve\"><\/span>Quick Answer: How to Choose a Check Valve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>To choose a check valve, first define the operating conditions, then match the valve type to the system behavior. The valve should open reliably at the normal flow rate, close before damaging reverse flow develops, and avoid excessive pressure drop, chatter, or water hammer.<\/p>\n<p>A practical selection path is:<\/p>\n<table>\n<thead>\n<tr>\n<th>Step<\/th>\n<th>What to Check<\/th>\n<th>Why It Matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Media and service condition<\/td>\n<td>Viscosity, solids, corrosion, steam, gas, or slurry-like service can change valve behavior<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Flow rate and pressure<\/td>\n<td>The valve must open at normal flow and avoid excessive pressure drop<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Valve type<\/td>\n<td>Swing, lift, ball, dual plate, nozzle, and spring-loaded valves close differently<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Installation position<\/td>\n<td>Horizontal or vertical installation affects disc, ball, piston, or spring movement<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Specification details<\/td>\n<td>Material, seat, pressure class, end connection, and datasheet limits must match the project<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pipe size should confirm the connection, not complete the selection. If the real flow is too low for the selected valve, the disc or closing element may stay partially open, creating chatter, vibration, seat wear, and unnecessary head loss.<\/p>\n<p>For additional background on why check valves should be sized by application and flow rather than line size alone, see this <a href=\"https:\/\/blog.craneengineering.net\/checkvalve\" target=\"_blank\" rel=\"noopener\">check valve sizing reference<\/a>.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Start_With_Service_Conditions_Not_Pipe_Size_Alone\"><\/span>Start With Service Conditions, Not Pipe Size Alone<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pipe size is only one input. A valve with the same nominal size can behave very differently depending on flow velocity, disc movement, spring force, seat design, and body geometry.<\/p>\n<p>A check valve selected only by line size may be too large for the real flow. In low-flow operation, the disc may not reach a stable fully open position. That unstable position is where flutter, chatter, vibration, premature wear, and inconsistent pressure loss usually begin.<\/p>\n<p>For industrial check valve selection, the first question should be:<\/p>\n<p><strong>What does the system need the valve to do under real operating conditions?<\/strong><\/p>\n<h3><span class=\"ez-toc-section\" id=\"A_Practical_5-Step_Check_Valve_Selection_Path\"><\/span>A Practical 5-Step Check Valve Selection Path<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The five-step path above should be used as a decision sequence, not as separate checklist items. Media and flow conditions define the operating window; valve type and installation define how the internal element moves; pressure drop and closing response define whether the valve will remain stable in service.<\/p>\n<p>A selection guide is useful only when it connects these items together. A valve that looks correct by size may still fail the fit-check if it cannot open fully, closes too slowly, creates excessive head loss, or cannot be installed in the required orientation.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_a_Selection_Chart_Is_Helpful%E2%80%94and_When_It_Is_Not_Enough\"><\/span>When a Selection Chart Is Helpful\u2014and When It Is Not Enough<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A check valve selection chart is useful for early screening. It helps compare valve types by application, pressure drop tendency, closing response, and media condition.<\/p>\n<p>However, a chart should not be the final selection method. The final valve choice still needs project data, manufacturer datasheets, pressure class confirmation, material compatibility review, and installation verification.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_a_Check_Valve_Selection_Guide_Should_Decide\"><\/span>What a Check Valve Selection Guide Should Decide<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve allows flow in one direction and prevents reverse flow when pressure conditions change. In pump discharge lines, process piping, water systems, steam and condensate service, chemical lines, and other industrial applications, this automatic non-return function protects equipment and helps maintain system direction.<\/p>\n<p>But \u201ccheck valve\u201d is a broad term. Different designs close at different speeds, create different flow resistance, and tolerate different media conditions.<\/p>\n<p>A good selection guide should answer these questions:<\/p>\n<ul>\n<li>Which valve type fits the service?<\/li>\n<li>Will the valve open fully at the expected flow rate?<\/li>\n<li>How much pressure drop or head loss is acceptable?<\/li>\n<li>Is the system sensitive to slam or water hammer?<\/li>\n<li>Can the valve be installed in the required orientation?<\/li>\n<li>Is the material compatible with the fluid and temperature?<\/li>\n<li>What information should be confirmed before RFQ?<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"What_a_Check_Valve_Does_in_an_Industrial_System\"><\/span>What a Check Valve Does in an Industrial System<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>In industrial systems, a check valve is usually installed to prevent reverse flow after pump shutdown, pressure fluctuation, or process interruption. It may protect pumps, compressors, meters, filters, heat exchangers, tanks, or upstream equipment.<\/p>\n<p>The valve does not regulate flow like a control valve and should not be treated as a throttling device. Its main job is to open when forward flow is sufficient and close when reverse flow begins or when forward pressure falls below the closing condition.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Check_Valve_vs_Non-Return_Valve_Terminology_Boundary\"><\/span>Check Valve vs Non-Return Valve: Terminology Boundary<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>\u201cCheck valve\u201d and \u201cnon-return valve\u201d are often used for the same general function: allowing flow in one direction and preventing reverse flow. In some markets, \u201cNRV\u201d is used more frequently in pump, water, or general piping contexts.<\/p>\n<p>This article focuses on check valve selection. A full explanation of NRV terminology, NRV types, and non-return valve definitions should remain on a dedicated NRV page, not inside this selection guide.<\/p>\n<p>For a deeper terminology explanation, see NTGD\u2019s guide to <a href=\"https:\/\/ntgdvalve.com\/nrv-valve\/\">NRV valve meaning, working principle, and industrial NRV types<\/a>.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_This_Guide_Does_Not_Replace\"><\/span>What This Guide Does Not Replace<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>This guide is for initial engineering selection and RFQ preparation. It does not replace:<\/p>\n<ul>\n<li>project specifications;<\/li>\n<li>manufacturer datasheets;<\/li>\n<li>applicable standards;<\/li>\n<li>pressure drop calculation;<\/li>\n<li>surge analysis;<\/li>\n<li>installation instructions;<\/li>\n<li>detailed sizing review for critical systems.<\/li>\n<\/ul>\n<p>For severe service, hazardous media, high pressure, high temperature, or water hammer-sensitive systems, the final selection should be checked against the project specification and valve datasheet.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Common_Check_Valve_Types_in_Selection_Context\"><\/span>Common Check Valve Types in Selection Context<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The purpose of this section is not to create a full check valve types article. The goal is to show how common check valve types affect selection decisions.<\/p>\n<p>Different valve types vary in pressure drop, closing speed, installation sensitivity, maintenance access, and tolerance for solids or unstable flow.<\/p>\n<figure id=\"attachment_9793\" aria-describedby=\"caption-attachment-9793\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-9793\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-types-selection-context.png\" alt=\"Check valve types in selection context including swing, lift piston, ball, dual plate wafer and silent nozzle designs\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-types-selection-context.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-types-selection-context-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-types-selection-context-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-types-selection-context-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-types-selection-context-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9793\" class=\"wp-caption-text\">Different check valve types should be compared by service fit, not by name alone.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Swing_Check_Valves\"><\/span>Swing Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Swing check valves use a hinged disc that opens with forward flow and closes when flow reverses. They are often reviewed for larger pipelines and relatively steady flow conditions.<\/p>\n<p>They may offer lower flow resistance when fully open, but the disc can close more slowly than spring-assisted designs. In pump shutdown or rapid flow reversal systems, slam and water hammer risk should be reviewed before using a swing check valve as the default choice.<\/p>\n<p>When the service points toward a hinged-disc design, review the <a href=\"https:\/\/ntgdvalve.com\/swing-check-valve\/\">swing check valve<\/a> details after confirming flow stability, orientation, and slam risk.<\/p>\n<figure id=\"attachment_9789\" aria-describedby=\"caption-attachment-9789\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-9789\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-scaled.jpg\" alt=\"24 inch 900LB CA15 flanged swing check valve in NTGD workshop\" width=\"2560\" height=\"1706\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-24-inch-900lb-ca15-flanged-workshop-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9789\" class=\"wp-caption-text\">Large swing check valve example for high-pressure industrial service review.<\/figcaption><\/figure>\n<div style=\"position: relative; width: 100%; max-width: 100%; padding-bottom: 56.25%; height: 0; overflow: hidden; margin: 24px 0;\"><iframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0;\" title=\"NTGD Swing Check Valve\" src=\"https:\/\/www.youtube.com\/embed\/1ewvEqwuRbs\" allowfullscreen=\"allowfullscreen\"><br \/>\n<\/iframe><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Lift_and_Piston_Check_Valves\"><\/span>Lift and Piston Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Lift and piston check valves use a guided disc or piston that moves away from the seat under forward flow. They are often reviewed for clean media and higher-pressure applications where guided movement and tighter seating are useful.<\/p>\n<p>Their internal flow path can create higher pressure drop compared with some full-opening designs. Installation orientation and clean service conditions should be checked carefully.<\/p>\n<p>For clean service where guided disc movement is preferred, compare the service data with NTGD\u2019s <a href=\"https:\/\/ntgdvalve.com\/lift-check-valve\/\">lift check valve<\/a> configuration and datasheet limits.<\/p>\n<figure id=\"attachment_9786\" aria-describedby=\"caption-attachment-9786\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9786\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-scaled.jpg\" alt=\"DN100 1500LB A105 lift piston check valve for high pressure clean service\" width=\"2560\" height=\"1706\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-lift-piston-type-dn100-1500lb-a105-high-pressure-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9786\" class=\"wp-caption-text\">Lift and piston check valves are often reviewed where guided movement and pressure rating are important.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Ball_Check_Valves\"><\/span>Ball Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Ball check valves use a ball as the closing element. Depending on the design, they can be useful in wastewater or solids-containing services where simple closure and reduced clogging sensitivity are desired.<\/p>\n<p>They are not universal. High-pressure service, precise sealing requirements, high-temperature service, or orientation-sensitive applications require careful review of the valve design and datasheet.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Dual_Plate_and_Wafer_Check_Valves\"><\/span>Dual Plate and Wafer Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Dual plate and wafer check valves are compact designs often used where face-to-face space is limited. They can be attractive for flanged piping layouts where a shorter valve body is needed.<\/p>\n<p>Selection should consider spring and disc behavior, flow velocity, pressure drop, and media cleanliness. Solids, debris, or very unstable flow may affect performance.<\/p>\n<p>If the choice is mainly between compact wafer construction and a larger swing design, the <a href=\"https:\/\/ntgdvalve.com\/wafer-check-valves-vs-swing-check-valves-a-complete-guide\/\">wafer check valve vs swing check valve comparison<\/a> can help narrow the selection before RFQ.<\/p>\n<figure id=\"attachment_9791\" aria-describedby=\"caption-attachment-9791\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9791\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-scaled.jpg\" alt=\"DN1800 PN10 5A dual plate check valve during workshop inspection\" width=\"2560\" height=\"1707\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-dual-plate-dn1800-pn10-5a-workshop-inspection-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9791\" class=\"wp-caption-text\">Large dual plate check valves are commonly reviewed where compact flanged construction and pipeline scale matter.<\/figcaption><\/figure>\n<div style=\"position: relative; width: 100%; max-width: 100%; padding-bottom: 56.25%; height: 0; overflow: hidden; margin: 24px 0;\"><iframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0;\" title=\"How Big Is DN1500? Dual Plate Check Valve in Real Factory Conditions\" src=\"https:\/\/www.youtube.com\/embed\/EYkNZYN2n0A\" allowfullscreen=\"allowfullscreen\"><br \/>\n<\/iframe><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Nozzle_Silent_and_Spring-Loaded_Check_Valves\"><\/span>Nozzle, Silent and Spring-Loaded Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Nozzle, silent, and spring-loaded check valves are often reviewed when fast closing is needed to reduce reverse flow and slam. These designs may be useful near pump discharge or in systems sensitive to water hammer.<\/p>\n<p>They still require careful selection. Spring force, cracking pressure, pressure drop, solids sensitivity, and maintenance access should be reviewed before selection.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Tilting_Disc_and_Special-Service_Check_Valves\"><\/span>Tilting Disc and Special-Service Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Tilting disc and other special-service designs may be selected for large lines, lower pressure drop targets, or special dynamic response requirements. They should be reviewed based on service data, project specification, and manufacturer design.<\/p>\n<p>Special-service check valves should not be selected by name alone. The actual closing behavior, pressure loss, and installation conditions matter more than the label.<\/p>\n<figure id=\"attachment_9788\" aria-describedby=\"caption-attachment-9788\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9788\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-scaled.jpg\" alt=\"16 inch 150LB G63M flanged tilting disc check valve in workshop\" width=\"2560\" height=\"1707\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-tilting-disc-16-inch-150lb-g63m-flanged-workshop-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9788\" class=\"wp-caption-text\">Tilting disc check valves should be reviewed by service data, pressure loss target and dynamic response requirement.<\/figcaption><\/figure>\n<div style=\"position: relative; width: 100%; max-width: 100%; padding-bottom: 56.25%; height: 0; overflow: hidden; margin: 24px 0;\"><iframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0;\" title=\"NTGD 56-inch Tilting Type Check Valve with Counterweight and Hydraulic Station\" src=\"https:\/\/www.youtube.com\/embed\/S1CASnQU3rE\" allowfullscreen=\"allowfullscreen\"><br \/>\n<\/iframe><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Check_Valve_Type_vs_Application_Fit_Table\"><\/span>Check Valve Type vs Application Fit Table<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Valve Type<\/th>\n<th>Typical Fit<\/th>\n<th>Watch For<\/th>\n<th>Pressure Drop Tendency<\/th>\n<th>Closing Response<\/th>\n<th>Installation Notes<\/th>\n<th>Selection Implication<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Swing check valve<\/td>\n<td>Large pipelines, steady flow, water or general service<\/td>\n<td>Review slam risk in pump shutdown or rapid reverse-flow systems; check hinge wear<\/td>\n<td>Often lower when fully open, depending on design<\/td>\n<td>Slower than spring-assisted types<\/td>\n<td>Confirm horizontal \/ vertical suitability<\/td>\n<td>Good screening option when low resistance matters, but not enough for surge-sensitive systems<\/td>\n<\/tr>\n<tr>\n<td>Lift \/ piston check valve<\/td>\n<td>Clean media, higher pressure, guided closure<\/td>\n<td>Higher flow resistance, clean-service requirement<\/td>\n<td>Usually higher than full-opening swing types<\/td>\n<td>Guided closure, design-dependent<\/td>\n<td>Orientation can be sensitive<\/td>\n<td>Useful when guided seating matters more than minimum pressure loss<\/td>\n<\/tr>\n<tr>\n<td>Ball check valve<\/td>\n<td>Wastewater, some solids-containing or low-head services<\/td>\n<td>Not universal for high pressure, high temperature, or all orientations<\/td>\n<td>Depends on body and ball path<\/td>\n<td>Gravity \/ flow dependent<\/td>\n<td>Confirm vertical or horizontal suitability<\/td>\n<td>Review when debris tolerance matters, but verify sealing and pressure limits<\/td>\n<\/tr>\n<tr>\n<td>Dual plate \/ wafer check valve<\/td>\n<td>Compact flanged piping, limited space<\/td>\n<td>Spring \/ disc wear, solids sensitivity<\/td>\n<td>Medium, design-dependent<\/td>\n<td>Faster than standard swing<\/td>\n<td>Requires flow velocity review<\/td>\n<td>Useful for compact layouts, but not a substitute for flow stability review<\/td>\n<\/tr>\n<tr>\n<td>Nozzle \/ silent check valve<\/td>\n<td>Pump discharge, non-slam needs, surge-sensitive systems<\/td>\n<td>Pressure drop, spring force, solids sensitivity<\/td>\n<td>Medium to higher, depending on design<\/td>\n<td>Fast closing<\/td>\n<td>Datasheet review required<\/td>\n<td>Review when closing response is a primary selection factor<\/td>\n<\/tr>\n<tr>\n<td>Tilting disc check valve<\/td>\n<td>Large lines, lower head loss review, special applications<\/td>\n<td>Cost, service limits, maintenance access<\/td>\n<td>Can be lower in some designs<\/td>\n<td>Faster than standard swing in some applications<\/td>\n<td>Application review required<\/td>\n<td>Consider when both flow loss and dynamic response need engineering review<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For full construction details, dimensions, pressure-temperature ratings, end connection options, and product-specific limits, use dedicated valve type or product resources. This table is a selection aid, not a product specification chart.<\/p>\n<p>For full type-by-type construction details and application boundaries, use the dedicated <a href=\"https:\/\/ntgdvalve.com\/9-types-of-check-valves-and-their-key-features\/\">check valve types guide<\/a> rather than expanding this selection guide into a types hub.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Check_Valve_Selection_Criteria_Matrix\"><\/span>Check Valve Selection Criteria Matrix<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve selection criteria matrix helps convert broad system conditions into practical decisions. The valve should be selected based on how it behaves in the actual service, not only on nominal diameter or a general valve type name.<\/p>\n<figure id=\"attachment_9798\" aria-describedby=\"caption-attachment-9798\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9798\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-criteria-flow-pressure-drop.png\" alt=\"Check valve selection criteria diagram showing media, flow rate, pressure drop, cracking pressure and maintenance access\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-criteria-flow-pressure-drop.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-criteria-flow-pressure-drop-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-criteria-flow-pressure-drop-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-criteria-flow-pressure-drop-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-criteria-flow-pressure-drop-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9798\" class=\"wp-caption-text\">Core selection criteria connect system data with valve behavior in service.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Media_and_Fluid_Compatibility\"><\/span>Media and Fluid Compatibility<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The media affects material choice, seat compatibility, sealing behavior, and the risk of fouling or sticking.<\/p>\n<p>Water, wastewater, steam, condensate, gas, oil, chemical fluid, viscous media, and solids-containing service can each require different valve designs. Corrosive or abrasive fluids need special attention to body material, trim material, seat material, and maintenance access.<\/p>\n<p>Using incompatible materials can lead to accelerated corrosion, seat leakage, sticking internal parts, or unsafe service in chemical or hazardous applications.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Flow_Rate_Flow_Velocity_and_Minimum_Flow\"><\/span>Flow Rate, Flow Velocity and Minimum Flow<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The valve must open enough under normal flow. If the flow is too low for the valve design, the disc, ball, or piston may not reach a stable open position. This can cause chatter, vibration, noise, or wear.<\/p>\n<p>Flow velocity also affects pressure drop, closure response, and the risk of slam during reversal. For critical systems, flow data should be checked against the valve datasheet rather than estimated from pipe size alone.<\/p>\n<p>Insufficient flow velocity can keep the closing element in a partially open position, causing vibration, unstable pressure drop, and premature seat wear.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Operating_Pressure_Temperature_and_Pressure_Class\"><\/span>Operating Pressure, Temperature and Pressure Class<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The valve pressure class must match the system design pressure and operating pressure. Temperature also affects material selection, seat selection, spring behavior, and fluid properties.<\/p>\n<p>For high-temperature, cryogenic, steam, or corrosive service, the material and seat must be verified against the project specification and datasheet. A correct body pressure class does not automatically confirm that the seat, spring, seal, or trim material is suitable for the service temperature and media.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Material_Seat_and_Seal_Compatibility\"><\/span>Material, Seat and Seal Compatibility<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Body material, disc material, spring material, seat material, and seal material should match the media and temperature. A valve body may be acceptable for pressure, but the seat or internal components may still be unsuitable for the fluid.<\/p>\n<p>Soft seats may help sealing in some services, but temperature, chemical compatibility, and wear resistance must be checked. Metal seats may tolerate higher temperature or abrasive service better in some designs, but sealing expectations should be confirmed.<\/p>\n<p>If the seat or seal is not compatible with the media, the valve may leak even when the body material appears suitable.<\/p>\n<p>For corrosion-driven services, use the <a href=\"https:\/\/ntgdvalve.com\/stainless-steel-check-valve\/\">stainless steel check valve<\/a> page as a product-level reference after confirming media chemistry and temperature.<\/p>\n<figure id=\"attachment_9787\" aria-describedby=\"caption-attachment-9787\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9787\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-scaled.jpg\" alt=\"8 inch 150LB WCB rubber lined swing check valve in blue coating\" width=\"2560\" height=\"1707\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-8-inch-150lb-wcb-rubber-lined-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9787\" class=\"wp-caption-text\">Material and lining choices should be matched to media condition and service requirements.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Cracking_Pressure_and_Opening_Conditions\"><\/span>Cracking Pressure and Opening Conditions<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cracking pressure is the minimum upstream pressure required to start opening the check valve. It is especially important for spring-loaded check valves, small check valves, and low-pressure systems.<\/p>\n<p>If cracking pressure is too high, the valve may not open properly at low flow. If it is too low for the system behavior, the valve may become unstable or fail to provide the intended response. The exact requirement depends on valve design and service conditions.<\/p>\n<p>If cracking pressure does not match the available differential pressure, the valve may fail to open at normal flow or may operate unstably near the opening point.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Maintenance_Access_and_Lifecycle_Considerations\"><\/span>Maintenance Access and Lifecycle Considerations<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A low initial cost does not always mean a better selection. Maintenance access, seat wear, fouling risk, spare parts availability, and downtime exposure should be reviewed before the valve type is locked.<\/p>\n<p>For buried lines, high locations, hazardous media, or continuous operation systems, maintainability can be as important as the initial valve type.<\/p>\n<p>Poor maintenance access can turn a minor seat or hinge issue into longer downtime and higher lifecycle exposure.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Check_Valve_Selection_Criteria_Matrix-2\"><\/span>Check Valve Selection Criteria Matrix<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Criterion<\/th>\n<th>Why It Matters<\/th>\n<th>What to Confirm<\/th>\n<th>Risk If Ignored<\/th>\n<th>Selection Direction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Media type<\/td>\n<td>Determines material, seat, and fouling risk<\/td>\n<td>Water, steam, gas, chemical, slurry-like, viscous or solids-containing media<\/td>\n<td>Corrosion, sticking, seat damage, leakage, unsafe service<\/td>\n<td>Choose compatible body, trim and seat<\/td>\n<\/tr>\n<tr>\n<td>Flow rate<\/td>\n<td>Determines whether the valve opens fully<\/td>\n<td>Normal flow, minimum flow, intermittent flow<\/td>\n<td>Partial opening, chatter, vibration, wear<\/td>\n<td>Size by flow conditions, not pipe size alone<\/td>\n<\/tr>\n<tr>\n<td>Pressure and temperature<\/td>\n<td>Affects pressure class and material limits<\/td>\n<td>Operating pressure, design pressure, temperature range<\/td>\n<td>Body, seat, spring or seal mismatch<\/td>\n<td>Confirm pressure class and temperature limits<\/td>\n<\/tr>\n<tr>\n<td>Pressure drop \/ head loss<\/td>\n<td>Affects energy loss and system performance<\/td>\n<td>Allowable pressure drop, Cv \/ Kv, flow resistance<\/td>\n<td>High energy loss, restricted flow, unstable service<\/td>\n<td>Compare valve design and flow path<\/td>\n<\/tr>\n<tr>\n<td>Cracking pressure<\/td>\n<td>Affects opening behavior<\/td>\n<td>Required opening pressure and low-flow condition<\/td>\n<td>Failure to open, unstable operation near opening point<\/td>\n<td>Confirm spring or disc opening data<\/td>\n<\/tr>\n<tr>\n<td>Closing response<\/td>\n<td>Affects reverse flow and slam<\/td>\n<td>Pump shutdown, surge risk, reverse flow speed<\/td>\n<td>Water hammer, noise, pipe stress<\/td>\n<td>Consider non-slam or fast-closing design<\/td>\n<\/tr>\n<tr>\n<td>Installation orientation<\/td>\n<td>Affects internal moving parts<\/td>\n<td>Horizontal, vertical upward, vertical downward<\/td>\n<td>Incomplete opening, sticking, failure to close<\/td>\n<td>Confirm allowable orientation<\/td>\n<\/tr>\n<tr>\n<td>Material and seat<\/td>\n<td>Affects corrosion, leakage and wear<\/td>\n<td>Body, disc, spring, seat, seal materials<\/td>\n<td>Leakage, corrosion, short service life<\/td>\n<td>Match material to media and temperature<\/td>\n<\/tr>\n<tr>\n<td>Maintenance access<\/td>\n<td>Affects lifecycle cost and downtime<\/td>\n<td>Access space, removable cover, inspection needs<\/td>\n<td>Longer downtime, difficult repair, higher lifecycle exposure<\/td>\n<td>Consider serviceability early<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These criteria work together. A valve may pass the material check but fail the pressure drop check; another may offer low resistance but close too slowly for a surge-sensitive pump line. The final fit-check should compare all critical criteria before the valve type is locked.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Flow_Rate_Pressure_Drop_and_Head_Loss\"><\/span>Flow Rate, Pressure Drop and Head Loss<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Pressure drop is one of the most important factors in check valve selection. A check valve is not just an on-off device. It becomes part of the piping resistance, and its internal geometry can affect flow efficiency.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Why_Check_Valves_Should_Be_Sized_by_Flow_Conditions\"><\/span>Why Check Valves Should Be Sized by Flow Conditions<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A check valve should be selected for the actual flow conditions. Nominal pipe size alone does not confirm that the internal element will open fully or operate stably.<\/p>\n<p>If a valve is oversized for the real flow, the disc may float in a partially open position. This can cause vibration, chatter, seat wear, and unstable pressure drop. If a valve is too restrictive, it may increase head loss and reduce system efficiency.<\/p>\n<p>A practical review should include:<\/p>\n<ul>\n<li>normal flow rate;<\/li>\n<li>minimum flow rate;<\/li>\n<li>maximum flow rate;<\/li>\n<li>start-up and shutdown behavior;<\/li>\n<li>pump curve or system operating range when available;<\/li>\n<li>acceptable pressure drop.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"How_Pressure_Drop_Affects_System_Performance\"><\/span>How Pressure Drop Affects System Performance<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pressure drop across a check valve can affect pump selection, energy use, flow delivery, and system stability. In some systems, a small increase in head loss may be acceptable. In others, it can reduce process performance or increase operating cost.<\/p>\n<p>Valve body shape, disc position, spring force, bore restriction, and internal flow path all affect pressure drop. This is why two check valves with the same nominal size and pressure class can perform differently.<\/p>\n<p>A pressure drop review should be tied to the actual duty point. A valve that looks acceptable at one flow rate may create excessive head loss or unstable movement at another.<\/p>\n<figure id=\"attachment_9800\" aria-describedby=\"caption-attachment-9800\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9800\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-pressure-drop-head-loss-comparison.png\" alt=\"Check valve pressure drop and head loss comparison between stable flow and high head loss conditions\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-pressure-drop-head-loss-comparison.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-pressure-drop-head-loss-comparison-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-pressure-drop-head-loss-comparison-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-pressure-drop-head-loss-comparison-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-pressure-drop-head-loss-comparison-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9800\" class=\"wp-caption-text\">Pressure drop should be reviewed against the actual flow condition, not only nominal valve size.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Cv_Kv_Head_Loss_and_Flow_Resistance_in_Practical_Selection\"><\/span>Cv \/ Kv, Head Loss and Flow Resistance in Practical Selection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cv and Kv are flow coefficient values used to compare how much flow a valve can pass under a given pressure differential. They are useful for comparing valve designs, but they should be read with the manufacturer\u2019s datasheet and the actual service condition.<\/p>\n<p>For the general relationship between Cv \/ Kv, flow rate, and pressure loss, refer to this <a href=\"https:\/\/www.pipeflow.com\/public\/PipeFlowExpertSoftwareHelp\/html\/CvandKvFlowCoefficients1.html\" target=\"_blank\" rel=\"noopener\">Cv and Kv flow coefficient reference<\/a>.<\/p>\n<p>For practical selection:<\/p>\n<ul>\n<li>higher flow coefficient usually indicates lower resistance, but only under the stated test or design conditions;<\/li>\n<li>a low pressure drop design may still be unsuitable if it closes too slowly;<\/li>\n<li>a fast-closing design may reduce slam risk but can have different pressure drop behavior;<\/li>\n<li>solids, viscosity, and partial opening can change real performance.<\/li>\n<\/ul>\n<p>When comparing Cv or Kv values, use the actual operating flow rate and pressure differential, not only nominal pipe size. Oversized valves can operate at partial opening, where the effective pressure drop and wear behavior may be worse than the catalog comparison suggests.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Low_Pressure_Drop_Does_Not_Automatically_Mean_Best_Selection\"><\/span>Low Pressure Drop Does Not Automatically Mean Best Selection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A valve with low pressure drop is not always the best check valve. If the system has rapid flow reversal, pump shutdown, or surge risk, closing response may be more important than minimum resistance.<\/p>\n<p>Selection should balance:<\/p>\n<ul>\n<li>pressure drop;<\/li>\n<li>closing speed;<\/li>\n<li>media compatibility;<\/li>\n<li>installation orientation;<\/li>\n<li>maintenance access;<\/li>\n<li>project specification.<\/li>\n<\/ul>\n<p>There is often a trade-off between low head loss and fast closing response. A design that minimizes resistance may not close quickly enough for a surge-sensitive system, while a fast-closing design may require closer review of pressure drop, spring force, and minimum flow.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Flow_Direction_Body_Arrow_and_Installation_Orientation\"><\/span>Flow Direction, Body Arrow and Installation Orientation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve must be installed in the correct flow direction. If the valve is installed backward, it may block flow, fail to protect the system, or create abnormal pressure conditions.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Why_Flow_Direction_Matters_for_Check_Valve_Selection\"><\/span>Why Flow Direction Matters for Check Valve Selection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Most check valves have a body arrow or marking that indicates the intended flow direction. The valve must be installed so forward flow follows this marking.<\/p>\n<p>Flow direction also affects how the internal element moves. A swing disc, lift disc, piston, ball, or spring-assisted element may depend on gravity, flow force, spring force, or guided movement. The wrong direction can prevent normal opening and closing.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Horizontal_vs_Vertical_Installation\"><\/span>Horizontal vs Vertical Installation<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not every check valve is suitable for every orientation. Some valves may work in horizontal lines, some in vertical upward flow, and some may have restrictions for vertical downward flow.<\/p>\n<p>The installation orientation should be checked before selection, especially for:<\/p>\n<ul>\n<li>swing check valves;<\/li>\n<li>lift and piston check valves;<\/li>\n<li>ball check valves;<\/li>\n<li>dual plate or wafer check valves;<\/li>\n<li>spring-loaded or silent check valves.<\/li>\n<\/ul>\n<p>Vertical downward flow requires extra caution and datasheet confirmation because gravity and closing-element movement can affect opening, seating, and complete closure. Do not assume vertical installation is acceptable unless the valve design supports it.<\/p>\n<figure id=\"attachment_9795\" aria-describedby=\"caption-attachment-9795\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9795\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-flow-direction-orientation-check.png\" alt=\"Check valve flow direction and orientation check showing correct direction, wrong direction and datasheet confirmation\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-flow-direction-orientation-check.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-flow-direction-orientation-check-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-flow-direction-orientation-check-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-flow-direction-orientation-check-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-flow-direction-orientation-check-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9795\" class=\"wp-caption-text\">Flow direction and installation orientation must be confirmed before the valve is ordered or installed.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Pump_Discharge_Elbows_and_Unstable_Flow_Areas\"><\/span>Pump Discharge, Elbows and Unstable Flow Areas<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Check valves often operate near pumps, elbows, reducers, tees, or other sources of unstable flow. Turbulence can affect disc movement and closing behavior.<\/p>\n<p>If the valve is installed too close to disturbed flow, it may experience vibration, incomplete opening, noise, premature wear, or unstable closure. The exact placement should be checked against the project piping layout, manufacturer instructions, and applicable specifications.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_Installation_Conditions_Require_Datasheet_Confirmation\"><\/span>When Installation Conditions Require Datasheet Confirmation<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Datasheet confirmation is especially important when:<\/p>\n<ul>\n<li>the valve will be installed vertically;<\/li>\n<li>the valve is close to pump discharge;<\/li>\n<li>the system has frequent starts and stops;<\/li>\n<li>the media contains solids;<\/li>\n<li>the valve must control surge or water hammer risk;<\/li>\n<li>maintenance access is limited;<\/li>\n<li>pressure drop limits are strict.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Closing_Response_Water_Hammer_and_Non-Slam_Requirements\"><\/span>Closing Response, Water Hammer and Non-Slam Requirements<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve must close at the right time. If it closes too late, reverse flow can develop before shutoff. If it closes too abruptly under the wrong conditions, the system may experience pressure surge or water hammer.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Why_Check_Valve_Closing_Speed_Matters\"><\/span>Why Check Valve Closing Speed Matters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Closing speed affects reverse flow, noise, seat impact, and piping stress. A slow-closing valve may allow more reverse flow before the disc reaches the seat. A fast-closing valve may reduce reverse flow, but its suitability still depends on system pressure, flow velocity, media, and valve design.<\/p>\n<p>The goal is not simply to choose the fastest valve. The goal is to match closing behavior to the system dynamic.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Slam_Reverse_Flow_and_Water_Hammer_Risk\"><\/span>Slam, Reverse Flow and Water Hammer Risk<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Slam can occur when reverse flow forces the check valve closed suddenly. This can create noise, vibration, pressure surge, and stress on the valve and piping.<\/p>\n<p>Systems with pump shutdown, high flow velocity, long pipelines, rapid reversal, or unstable flow should be reviewed for water hammer risk. In these cases, valve type and closing response become major selection criteria.<\/p>\n<figure id=\"attachment_9794\" aria-describedby=\"caption-attachment-9794\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9794\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-slam-risk-non-slam-review.png\" alt=\"Check valve slam risk and non-slam review diagram for pump discharge service\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-slam-risk-non-slam-review.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-slam-risk-non-slam-review-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-slam-risk-non-slam-review-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-slam-risk-non-slam-review-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-slam-risk-non-slam-review-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9794\" class=\"wp-caption-text\">Closing response should match the system\u2019s reverse-flow and water hammer risk.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"When_to_Consider_Spring-Loaded_Silent_or_Nozzle_Check_Valves\"><\/span>When to Consider Spring-Loaded, Silent or Nozzle Check Valves<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Spring-loaded, silent, or nozzle check valves may be considered when the system needs faster closing or reduced slam risk. These designs can be useful near pump discharge or in systems where reverse flow must be minimized quickly.<\/p>\n<figure id=\"attachment_9785\" aria-describedby=\"caption-attachment-9785\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9785\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-scaled.jpg\" alt=\"DN600 PN64 WCB silent check valve front view for non-slam service review\" width=\"2560\" height=\"1707\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-silent-type-dn600-pn64-wcb-front-view-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9785\" class=\"wp-caption-text\">Silent check valves are reviewed when closing response and slam reduction are important.<\/figcaption><\/figure>\n<p>However, they should not be selected only because \u201cnon-slam\u201d sounds safer. The engineer should also check:<\/p>\n<ul>\n<li>cracking pressure;<\/li>\n<li>pressure drop;<\/li>\n<li>spring material;<\/li>\n<li>flow rate;<\/li>\n<li>media cleanliness;<\/li>\n<li>solids sensitivity;<\/li>\n<li>installation orientation;<\/li>\n<li>maintenance access.<\/li>\n<\/ul>\n<p>This selection guide uses spring-loaded, silent, and nozzle check valves only as closing-response options. Detailed construction, spring data, cracking pressure ranges, and product-specific limits should be checked in dedicated product or topic resources.<\/p>\n<p>For deeper non-slam selection boundaries, review NTGD\u2019s <a href=\"https:\/\/ntgdvalve.com\/spring-loaded-check-valve\/\">spring-loaded check valve guide<\/a> after the system\u2019s cracking pressure, pressure drop, and media cleanliness are known.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_Cracking_Pressure_Relates_to_Closing_and_Opening_Behavior\"><\/span>How Cracking Pressure Relates to Closing and Opening Behavior<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cracking pressure is not only a small-valve detail. It affects whether the valve can open under available upstream pressure.<\/p>\n<p>In low-pressure systems, a high cracking pressure may prevent proper opening. In systems requiring a specific closing response, spring force and cracking pressure may affect both opening and closure behavior.<\/p>\n<p>For spring-loaded or silent check valves, cracking pressure should be confirmed in the datasheet and matched to the actual flow and pressure conditions.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Check_Valve_Selection_Chart_by_Application_Fit\"><\/span>Check Valve Selection Chart by Application Fit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve selection chart is most useful when it helps users narrow the options before checking datasheets. It should not be treated as a final design decision.<\/p>\n<figure id=\"attachment_9797\" aria-describedby=\"caption-attachment-9797\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9797\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-service-condition-map.png\" alt=\"Check valve selection service condition map for water, steam, chemical, pump discharge, corrosive media and solids service\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-service-condition-map.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-service-condition-map-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-service-condition-map-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-service-condition-map-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-service-condition-map-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9797\" class=\"wp-caption-text\">Check valve selection should begin with service conditions before narrowing the valve type.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"How_to_Use_This_Check_Valve_Selection_Chart\"><\/span>How to Use This Check Valve Selection Chart<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Use the chart below as an early screening tool. It shows which valve directions are commonly reviewed for different service conditions. The final selection still depends on flow rate, pressure drop, installation orientation, materials, seat design, and project specification.<\/p>\n<p>Use this chart for initial screening only. It should not be the sole selection basis for severe service, hazardous or toxic media, cryogenic or high-temperature service, or systems with a known water hammer history.<\/p>\n<figure id=\"attachment_9801\" aria-describedby=\"caption-attachment-9801\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9801\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-chart-application-fit.png\" alt=\"Check valve selection chart showing service condition, review direction and key caution\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-chart-application-fit.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-chart-application-fit-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-chart-application-fit-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-chart-application-fit-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-selection-chart-application-fit-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9801\" class=\"wp-caption-text\">Use a selection chart for initial screening, then confirm datasheet limits and service data.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Application_Conditions_That_Usually_Drive_Valve_Choice\"><\/span>Application Conditions That Usually Drive Valve Choice<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Service Condition<\/th>\n<th>Common Valve Direction<\/th>\n<th>Pressure Drop Concern<\/th>\n<th>Water Hammer \/ Slam Concern<\/th>\n<th>Media \/ Solids Concern<\/th>\n<th>Selection Note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Large horizontal water line<\/td>\n<td>Swing or tilting disc check valve<\/td>\n<td>Usually reviewed for low head loss<\/td>\n<td>Review if pump shutdown or reversal is rapid<\/td>\n<td>Usually clean to moderately clean media<\/td>\n<td>Confirm closure speed and installation orientation<\/td>\n<\/tr>\n<tr>\n<td>Pump discharge with surge concern<\/td>\n<td>Silent, nozzle, or spring-assisted check valve<\/td>\n<td>Compare pressure drop against pump duty point<\/td>\n<td>High priority<\/td>\n<td>Clean media preferred for some designs<\/td>\n<td>Review closing speed, cracking pressure, and allowable head loss together<\/td>\n<\/tr>\n<tr>\n<td>Compact flanged piping<\/td>\n<td>Dual plate or wafer check valve<\/td>\n<td>Medium, design-dependent<\/td>\n<td>Medium to high depending system<\/td>\n<td>Solids may affect disc movement<\/td>\n<td>Confirm flow velocity and spring \/ disc suitability<\/td>\n<\/tr>\n<tr>\n<td>High-pressure clean service<\/td>\n<td>Lift or piston check valve<\/td>\n<td>Often higher than swing types<\/td>\n<td>Design-dependent<\/td>\n<td>Clean media preferred<\/td>\n<td>Confirm orientation and pressure class<\/td>\n<\/tr>\n<tr>\n<td>Wastewater or solids-containing service<\/td>\n<td>Ball check valve or selected swing designs<\/td>\n<td>Depends on body and solids path<\/td>\n<td>Review for slam and fouling<\/td>\n<td>High priority<\/td>\n<td>Confirm solids size, seat design and maintenance access<\/td>\n<\/tr>\n<tr>\n<td>Steam or condensate service<\/td>\n<td>Lift, piston, swing, or specialty check valve depending condition<\/td>\n<td>Must be reviewed carefully<\/td>\n<td>Depends on flow reversal and condensate behavior<\/td>\n<td>Cleanliness and temperature matter<\/td>\n<td>Confirm material, seat and temperature limits<\/td>\n<\/tr>\n<tr>\n<td>Corrosive chemical service<\/td>\n<td>Material-compatible check valve design<\/td>\n<td>Depends on selected type<\/td>\n<td>Application-specific<\/td>\n<td>High compatibility concern<\/td>\n<td>Confirm body, trim, seat and seal materials<\/td>\n<\/tr>\n<tr>\n<td>Low-flow or intermittent service<\/td>\n<td>Spring-assisted or properly sized guided design<\/td>\n<td>Avoid partial-opening operation<\/td>\n<td>Medium<\/td>\n<td>Depends on media<\/td>\n<td>Confirm minimum flow, cracking pressure, and stable opening behavior<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"When_the_Chart_Should_Trigger_Engineering_Review\"><\/span>When the Chart Should Trigger Engineering Review<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A selection chart should trigger further review when:<\/p>\n<ul>\n<li>the system has frequent pump starts and stops;<\/li>\n<li>water hammer has occurred before;<\/li>\n<li>pressure drop limits are strict;<\/li>\n<li>the valve is installed vertically;<\/li>\n<li>media contains solids or viscous fluid;<\/li>\n<li>the service is corrosive, hazardous, high-temperature, or high-pressure;<\/li>\n<li>the valve is near pump discharge, elbows, reducers, or tees;<\/li>\n<li>maintenance access is limited.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Common_Wrong_Selection_Risks\"><\/span>Common Wrong Selection Risks<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve may look simple, but wrong selection can create real operating problems. The most common mistakes are selecting only by pipe size, ignoring flow velocity, overlooking installation orientation, and choosing a valve type without considering closing behavior.<\/p>\n<figure id=\"attachment_9792\" aria-describedby=\"caption-attachment-9792\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9792\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-wrong-selection-risks-orientation-mismatch.png\" alt=\"Check valve wrong selection risks including chatter, high head loss, slam, fouling and orientation mismatch\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-wrong-selection-risks-orientation-mismatch.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-wrong-selection-risks-orientation-mismatch-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-wrong-selection-risks-orientation-mismatch-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-wrong-selection-risks-orientation-mismatch-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-wrong-selection-risks-orientation-mismatch-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9792\" class=\"wp-caption-text\">Wrong check valve selection can create operating risks even when the pipe size appears correct.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"High_Pressure_Drop_or_Energy_Loss\"><\/span>High Pressure Drop or Energy Loss<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A restrictive valve design can increase head loss. This may reduce flow, increase pump load, or reduce system efficiency. Pressure drop should be reviewed before final selection, especially in continuous operation systems.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Chatter_Flutter_or_Incomplete_Opening\"><\/span>Chatter, Flutter or Incomplete Opening<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If the valve does not open fully under normal flow, the internal element may flutter. This can cause noise, vibration, seat wear, and unstable pressure drop.<\/p>\n<p>This is often linked to oversized valves, low flow, unstable flow, or poor match between valve design and service.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Slam_and_Water_Hammer\"><\/span>Slam and Water Hammer<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If reverse flow develops before the valve closes, the disc or closing element can slam into the seat. This may create pressure surge, noise, vibration, and pipe stress.<\/p>\n<p>Systems with long lines, high velocity, pump shutdown, or rapid flow reversal should review non-slam or fast-closing options.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Fouling_Solids_Blockage_or_Sticking\"><\/span>Fouling, Solids Blockage or Sticking<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Solids, debris, scale, viscous fluids, or dirty media can interfere with disc, piston, spring, or ball movement. A valve that works well in clean water may fail in dirty service.<\/p>\n<p>Media cleanliness should be part of the selection criteria, not an afterthought.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Leakage_Seat_Wear_and_Maintenance_Problems\"><\/span>Leakage, Seat Wear and Maintenance Problems<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Wrong material, poor seat compatibility, unstable movement, or abrasive media can lead to leakage and maintenance issues.<\/p>\n<p>Maintenance access should be considered early. A valve that is difficult to inspect or service may increase downtime even if the initial purchase cost is lower.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Wrong_Selection_Risk_Matrix\"><\/span>Wrong Selection Risk Matrix<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Wrong Selection<\/th>\n<th>Possible Result<\/th>\n<th>Common Cause<\/th>\n<th>How to Reduce Risk<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Selecting by pipe size only<\/td>\n<td>Chatter, partial opening, unstable flow<\/td>\n<td>Flow rate too low for valve size<\/td>\n<td>Confirm normal and minimum flow<\/td>\n<\/tr>\n<tr>\n<td>Ignoring pressure drop<\/td>\n<td>Energy loss, restricted flow<\/td>\n<td>High-resistance internal geometry<\/td>\n<td>Compare Cv \/ Kv and head loss data<\/td>\n<\/tr>\n<tr>\n<td>Ignoring closing response<\/td>\n<td>Slam, water hammer, noise<\/td>\n<td>Slow closure in rapid reversal system<\/td>\n<td>Review non-slam or fast-closing designs<\/td>\n<\/tr>\n<tr>\n<td>Ignoring media condition<\/td>\n<td>Fouling, sticking, leakage<\/td>\n<td>Solids, viscous fluid, corrosion<\/td>\n<td>Match valve type and material to media<\/td>\n<\/tr>\n<tr>\n<td>Ignoring installation orientation<\/td>\n<td>Failure to open or close properly<\/td>\n<td>Valve not suitable for vertical or horizontal layout<\/td>\n<td>Confirm datasheet orientation limits<\/td>\n<\/tr>\n<tr>\n<td>Ignoring cracking pressure<\/td>\n<td>Valve does not open at low pressure<\/td>\n<td>Spring force too high for system<\/td>\n<td>Confirm cracking pressure with service data<\/td>\n<\/tr>\n<tr>\n<td>Ignoring maintenance access<\/td>\n<td>Higher downtime<\/td>\n<td>Valve difficult to inspect or service<\/td>\n<td>Check access and service requirements early<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Final_RFQ_and_Datasheet_Checklist_Before_Ordering\"><\/span>Final RFQ and Datasheet Checklist Before Ordering<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A good RFQ should not only ask for \u201cone check valve.\u201d It should include enough system data for the valve supplier or engineer to verify the correct design.<\/p>\n<p>Incomplete or inaccurate RFQ information is a common cause of wrong check valve selection. Missing flow data, media details, orientation, or pressure drop limits can lead to a valve that fits the pipe connection but fails the actual service.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"System_Data_to_Confirm_Before_Selecting_a_Check_Valve\"><\/span>System Data to Confirm Before Selecting a Check Valve<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Before final selection, confirm:<\/p>\n<ul>\n<li>media name and condition;<\/li>\n<li>whether the fluid is clean, corrosive, viscous, abrasive, or solids-containing;<\/li>\n<li>normal flow rate;<\/li>\n<li>minimum and maximum flow rate;<\/li>\n<li>operating pressure;<\/li>\n<li>design pressure;<\/li>\n<li>operating temperature;<\/li>\n<li>installation orientation;<\/li>\n<li>flow direction;<\/li>\n<li>pump start \/ stop frequency;<\/li>\n<li>water hammer or surge concern;<\/li>\n<li>allowable pressure drop;<\/li>\n<li>maintenance access.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Valve_Data_to_Confirm_Before_RFQ\"><\/span>Valve Data to Confirm Before RFQ<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The valve specification should confirm:<\/p>\n<ul>\n<li>valve type;<\/li>\n<li>size \/ NPS \/ DN;<\/li>\n<li>pressure class;<\/li>\n<li>body material;<\/li>\n<li>trim \/ disc \/ spring material;<\/li>\n<li>seat and seal material;<\/li>\n<li>end connection;<\/li>\n<li>face-to-face or installation space;<\/li>\n<li>cracking pressure if relevant;<\/li>\n<li>flow coefficient or pressure drop data if required;<\/li>\n<li>applicable standards or project requirements;<\/li>\n<li>datasheet limitations.<\/li>\n<\/ul>\n<p>For pressure-class-driven applications, review the <a href=\"https:\/\/ntgdvalve.com\/high-pressure-check-valve\/\">high-pressure check valve<\/a> requirements together with the project pressure, temperature, and material data.<\/p>\n<figure id=\"attachment_9799\" aria-describedby=\"caption-attachment-9799\" style=\"width: 1672px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9799\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-rfq-datasheet-checklist.png\" alt=\"Check valve RFQ datasheet checklist with system data and valve data fields\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-rfq-datasheet-checklist.png 1672w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-rfq-datasheet-checklist-768x432.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-rfq-datasheet-checklist-1536x864.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-rfq-datasheet-checklist-18x10.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-rfq-datasheet-checklist-600x338.png 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/><figcaption id=\"caption-attachment-9799\" class=\"wp-caption-text\">A clear RFQ should include both system data and valve specification data.<\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"When_to_Ask_for_Application_Review\"><\/span>When to Ask for Application Review<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Application review is recommended when:<\/p>\n<ul>\n<li>service is high pressure or high temperature;<\/li>\n<li>media is corrosive, hazardous, abrasive, or solids-containing;<\/li>\n<li>the system has water hammer risk;<\/li>\n<li>the valve will be installed vertically;<\/li>\n<li>allowable pressure drop is limited;<\/li>\n<li>the valve is near pump discharge or unstable flow;<\/li>\n<li>the project requires special materials or certification;<\/li>\n<li>failure would create major downtime or safety risk.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Final_RFQ_Datasheet_Checklist\"><\/span>Final RFQ \/ Datasheet Checklist<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th>Required Field<\/th>\n<th>Why It Matters<\/th>\n<th>Buyer \/ Engineer Should Confirm<\/th>\n<th>Affects Selection In<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Media<\/td>\n<td>Determines material, seat and fouling risk<\/td>\n<td>Fluid name, cleanliness, solids, corrosion<\/td>\n<td>Material, seat, valve type<\/td>\n<\/tr>\n<tr>\n<td>Flow rate<\/td>\n<td>Determines opening stability<\/td>\n<td>Normal, minimum and maximum flow<\/td>\n<td>Size, pressure drop, chatter risk<\/td>\n<\/tr>\n<tr>\n<td>Pressure<\/td>\n<td>Determines pressure class<\/td>\n<td>Operating and design pressure<\/td>\n<td>Body rating, seat, spring design<\/td>\n<\/tr>\n<tr>\n<td>Temperature<\/td>\n<td>Affects material and seat limits<\/td>\n<td>Normal and maximum temperature<\/td>\n<td>Material, seal, seat selection<\/td>\n<\/tr>\n<tr>\n<td>Valve size<\/td>\n<td>Must match system and flow<\/td>\n<td>DN \/ NPS and actual flow condition<\/td>\n<td>Body size, velocity, pressure drop<\/td>\n<\/tr>\n<tr>\n<td>End connection<\/td>\n<td>Must match piping<\/td>\n<td>Flanged, wafer, threaded, welded, or other<\/td>\n<td>Installation and product selection<\/td>\n<\/tr>\n<tr>\n<td>Installation orientation<\/td>\n<td>Affects internal movement<\/td>\n<td>Horizontal, vertical upward, vertical downward<\/td>\n<td>Valve type and datasheet limit<\/td>\n<\/tr>\n<tr>\n<td>Flow direction<\/td>\n<td>Prevents installation error<\/td>\n<td>Body arrow and system flow direction<\/td>\n<td>Installation and operation<\/td>\n<\/tr>\n<tr>\n<td>Pressure drop allowance<\/td>\n<td>Protects system performance<\/td>\n<td>Maximum allowable head loss<\/td>\n<td>Valve design and Cv \/ Kv<\/td>\n<\/tr>\n<tr>\n<td>Cracking pressure<\/td>\n<td>Affects opening behavior<\/td>\n<td>Required opening pressure<\/td>\n<td>Spring-loaded \/ low-pressure service<\/td>\n<\/tr>\n<tr>\n<td>Material \/ seat<\/td>\n<td>Affects compatibility and sealing<\/td>\n<td>Body, trim, seat, seal material<\/td>\n<td>Corrosion, leakage, temperature<\/td>\n<\/tr>\n<tr>\n<td>Water hammer concern<\/td>\n<td>Affects closing response<\/td>\n<td>Pump shutdown, surge history<\/td>\n<td>Non-slam \/ silent \/ nozzle review<\/td>\n<\/tr>\n<tr>\n<td>Maintenance access<\/td>\n<td>Affects lifecycle cost<\/td>\n<td>Access space and service interval<\/td>\n<td>Body style and installation planning<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"FAQ_About_Check_Valve_Selection\"><\/span>FAQ About Check Valve Selection<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_most_common_mistake_in_check_valve_selection\"><\/span>What is the most common mistake in check valve selection?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The most common mistake is selecting the valve by pipe size alone. Pipe size confirms the connection, but the valve still needs to match actual flow rate, minimum flow, pressure drop allowance, closing response, and installation orientation.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_are_the_main_check_valve_selection_criteria\"><\/span>What are the main check valve selection criteria?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The main selection criteria include media compatibility, flow rate, flow velocity, pressure drop, operating pressure, temperature, valve type, cracking pressure, installation orientation, closing response, material, seat design, and maintenance access.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_a_check_valve_selection_chart\"><\/span>What is a check valve selection chart?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A check valve selection chart is an initial screening table that compares valve types against service conditions. It can help narrow options, but it should not replace datasheet review, pressure drop confirmation, or engineering evaluation.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Should_a_check_valve_be_selected_by_pipe_size_or_flow_conditions\"><\/span>Should a check valve be selected by pipe size or flow conditions?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A check valve should not be selected by pipe size alone. Pipe size is important, but the valve must also match the actual flow rate, minimum flow, pressure drop allowance, and opening stability.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Which_check_valve_has_the_lowest_pressure_drop\"><\/span>Which check valve has the lowest pressure drop?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>There is no universal lowest pressure drop check valve. For many large-diameter clean water or wastewater lines, full-opening swing or tilting disc designs are often reviewed for lower resistance when fully open. In compact piping, dual plate designs may offer a better balance of space and pressure drop. Always verify pressure drop data against the actual flow condition and datasheet.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_a_check_valve_be_installed_vertically\"><\/span>Can a check valve be installed vertically?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Some check valves can be installed vertically, but not all designs are suitable for every vertical flow direction. Vertical downward flow needs extra caution because gravity and closing-element movement can affect opening and closure. Confirm the allowable orientation in the valve datasheet.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_does_flow_direction_affect_check_valve_selection\"><\/span>How does flow direction affect check valve selection?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A check valve must be installed in the intended flow direction, usually shown by a body arrow. Wrong direction can prevent opening, block flow, or stop the valve from protecting the system against reverse flow.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_cracking_pressure_in_a_check_valve\"><\/span>What is cracking pressure in a check valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cracking pressure is the minimum upstream pressure required to start opening the valve. It matters most in low-pressure systems, spring-loaded check valves, and applications with limited differential pressure.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_should_you_choose_a_spring-loaded_or_non-slam_check_valve\"><\/span>When should you choose a spring-loaded or non-slam check valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Spring-loaded, silent, or non-slam designs may be considered when the system has rapid flow reversal, pump shutdown, or water hammer risk. The final choice should also check pressure drop, cracking pressure, media cleanliness, and installation orientation. Detailed spring-loaded or silent check valve selection should be reviewed in dedicated product or topic resources.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_information_should_be_provided_before_requesting_a_check_valve_quote\"><\/span>What information should be provided before requesting a check valve quote?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Provide media, flow rate, pressure, temperature, pipe size, pressure class, material requirement, seat requirement, end connection, installation orientation, flow direction, pressure drop concern, and any water hammer or surge history.<\/p>\n<figure id=\"attachment_9790\" aria-describedby=\"caption-attachment-9790\" style=\"width: 2560px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-9790\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-scaled.jpg\" alt=\"Internal disc detail of a 24 inch 900LB CA15 swing check valve\" width=\"2560\" height=\"1707\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-scaled.jpg 2560w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-768x512.jpg 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-1536x1024.jpg 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-2048x1365.jpg 2048w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-18x12.jpg 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2026\/05\/check-valve-swing-type-disc-detail-24-inch-900lb-ca15-600x400.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-9790\" class=\"wp-caption-text\">The hinged disc movement is one reason swing check valves require closure and slam review.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion_Select_the_Check_Valve_by_System_Behavior_Not_by_Name_Alone\"><\/span>Conclusion: Select the Check Valve by System Behavior, Not by Name Alone<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A check valve should be selected by system behavior, not by valve name alone. The most suitable design depends on how the media flows, how quickly reverse flow develops, how much pressure drop the system can accept, and how the valve will be installed.<\/p>\n<p>For early screening, use a check valve selection chart. For engineering selection, confirm the full criteria: media, flow rate, pressure, temperature, pressure drop, cracking pressure, closing response, material, seat, end connection, installation orientation, and datasheet limits.<\/p>\n<p>The safest selection process is simple:<\/p>\n<ol>\n<li>Define the service conditions.<\/li>\n<li>Match the valve type to the application.<\/li>\n<li>Check pressure drop and flow stability.<\/li>\n<li>Review closing response and water hammer risk.<\/li>\n<li>Confirm material, pressure class, installation orientation, and RFQ data.<\/li>\n<\/ol>\n<p>A check valve that fits the system will usually perform better than one selected only by size, price, or a familiar valve type name.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Application_Specification_Support\"><\/span>Application \/ Specification Support<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"ntgd-cta-box\">\n<p>If you are preparing an industrial check valve RFQ, provide the service data listed in the checklist so the valve can be reviewed against the actual media, flow, pressure, temperature, orientation, pressure drop allowance, and closing-response requirements.<\/p>\n<p>After the checklist is complete, compare the service data with NTGD\u2019s <a href=\"https:\/\/ntgdvalve.com\/check-valve\/\">industrial check valve product range<\/a> before final specification review.<\/p>\n<p>NTGD Valve can support application and specification review based on these operating conditions, helping match the valve type, material, seat, end connection, and pressure class to the project requirements.<\/p>\n<p><script type=\"application\/ld+json\"> { \"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [ { \"@type\": \"Question\", \"name\": \"What is the most common mistake in check valve selection?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The most common mistake is selecting the valve by pipe size alone. Pipe size confirms the connection, but the valve still needs to match actual flow rate, minimum flow, pressure drop allowance, closing response, and installation orientation.\" } }, { \"@type\": \"Question\", \"name\": \"What are the main check valve selection criteria?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The main selection criteria include media compatibility, flow rate, flow velocity, pressure drop, operating pressure, temperature, valve type, cracking pressure, installation orientation, closing response, material, seat design, and maintenance access.\" } }, { \"@type\": \"Question\", \"name\": \"What is a check valve selection chart?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"A check valve selection chart is an initial screening table that compares valve types against service conditions. It can help narrow options, but it should not replace datasheet review, pressure drop confirmation, or engineering evaluation.\" } }, { \"@type\": \"Question\", \"name\": \"Should a check valve be selected by pipe size or flow conditions?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"A check valve should not be selected by pipe size alone. Pipe size is important, but the valve must also match the actual flow rate, minimum flow, pressure drop allowance, and opening stability.\" } }, { \"@type\": \"Question\", \"name\": \"Which check valve has the lowest pressure drop?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"There is no universal lowest pressure drop check valve. Full-opening swing or tilting disc designs are often reviewed for lower resistance in many large-diameter clean water or wastewater lines, while compact piping may require a different balance. Always verify pressure drop data against the actual flow condition and datasheet.\" } }, { \"@type\": \"Question\", \"name\": \"Can a check valve be installed vertically?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Some check valves can be installed vertically, but not all designs are suitable for every vertical flow direction. Vertical downward flow needs extra caution because gravity and closing-element movement can affect opening and closure. Confirm the allowable orientation in the valve datasheet.\" } }, { \"@type\": \"Question\", \"name\": \"How does flow direction affect check valve selection?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"A check valve must be installed in the intended flow direction, usually shown by a body arrow. Wrong direction can prevent opening, block flow, or stop the valve from protecting the system against reverse flow.\" } }, { \"@type\": \"Question\", \"name\": \"What is cracking pressure in a check valve?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Cracking pressure is the minimum upstream pressure required to start opening the valve. It matters most in low-pressure systems, spring-loaded check valves, and applications with limited differential pressure.\" } }, { \"@type\": \"Question\", \"name\": \"When should you choose a spring-loaded or non-slam check valve?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Spring-loaded, silent, or non-slam designs may be considered when the system has rapid flow reversal, pump shutdown, or water hammer risk. The final choice should also check pressure drop, cracking pressure, media cleanliness, and installation orientation.\" } }, { \"@type\": \"Question\", \"name\": \"What information should be provided before requesting a check valve quote?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Provide media, flow rate, pressure, temperature, pipe size, pressure class, material requirement, seat requirement, end connection, installation orientation, flow direction, pressure drop concern, and any water hammer or surge history.\" } } ] } <\/script><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Un guide pratique de s\u00e9lection des clapets anti-retour industriels couvrant les types de clapets, la direction du d\u00e9bit, la chute de pression, le risque de coup de b\u00e9lier, l'orientation de l'installation et les donn\u00e9es de l'appel d'offres pour une meilleure adaptation \u00e0 l'application.<\/p>","protected":false},"author":1,"featured_media":9801,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_eb_attr":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[45],"tags":[],"class_list":["post-9783","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/posts\/9783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/comments?post=9783"}],"version-history":[{"count":1,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/posts\/9783\/revisions"}],"predecessor-version":[{"id":9802,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/posts\/9783\/revisions\/9802"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/media\/9801"}],"wp:attachment":[{"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/media?parent=9783"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/categories?post=9783"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ntgdvalve.com\/fr\/wp-json\/wp\/v2\/tags?post=9783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}