{"id":4753,"date":"2024-07-15T12:27:44","date_gmt":"2024-07-15T12:27:44","guid":{"rendered":"https:\/\/sinovalveco.com\/product\/orbit-valve\/"},"modified":"2026-04-18T08:32:34","modified_gmt":"2026-04-18T08:32:34","slug":"orbit-valve","status":"publish","type":"product","link":"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/","title":{"rendered":"\u0428\u0430\u0440\u043e\u0432\u043e\u0439 \u043a\u0440\u0430\u043d \u0441 \u043f\u043e\u0434\u043d\u0438\u043c\u0430\u044e\u0449\u0438\u043c\u0441\u044f \u0448\u0442\u043e\u043a\u043e\u043c Orbit (Orbit Valve)"},"content":{"rendered":"<p data-start=\"77\" data-end=\"646\">An <strong data-start=\"80\" data-end=\"112\">orbit rising stem ball valve<\/strong>, commonly called an <strong data-start=\"133\" data-end=\"148\">orbit valve<\/strong>, is a severe-service isolation valve designed to achieve <strong data-start=\"206\" data-end=\"260\">tight shutoff without seat rubbing during rotation<\/strong>. Unlike a conventional ball valve, which turns against the seats during opening and closing, an orbit valve uses a <strong data-start=\"376\" data-end=\"394\">lift-then-turn<\/strong> mechanism: the core lifts away from the seat first, rotates without contact, and then wedges back into the shut position. This operating logic helps reduce seat wear, stabilize shutoff performance, and improve service life in demanding isolation duty.<\/p>\n<p data-start=\"648\" data-end=\"1112\">For engineers and buyers, the real question is not simply what an orbit valve is, but <strong data-start=\"734\" data-end=\"823\">when its non-rubbing shutoff design is worth selecting over a conventional ball valve<\/strong>. Orbit valves are typically specified where isolation reliability, repeatable shutoff, and reduced maintenance matter more than lowest first cost, such as <strong data-start=\"979\" data-end=\"1111\">gas transmission, molecular sieve dryer switching, meter isolation, emergency shutdown systems, and other critical block service<\/strong>.<\/p>\n<p data-start=\"1114\" data-end=\"1370\">NTGD supplies orbit rising stem ball valve solutions for project-oriented applications, with options for <strong data-start=\"1219\" data-end=\"1275\">manual, pneumatic, electric, and hydraulic actuation<\/strong>, as well as project-based material, pressure class, end connection, and documentation support.<\/p>\n<hr data-start=\"1478\" data-end=\"1481\" \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #0a0a0a;color:#0a0a0a\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #0a0a0a;color:#0a0a0a\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_Is_an_Orbit_Rising_Stem_Ball_Valve\" >What Is an Orbit Rising Stem Ball Valve?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_vs_Rising_Stem_Ball_Valve\" >Orbit Valve vs Rising Stem Ball Valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_vs_Orbital_Valve\" >Orbit Valve vs Orbital Valve<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#How_an_Orbit_Valve_Works\" >How an Orbit Valve Works<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Step_1_Closed_and_Mechanically_Wedged_Shut\" >Step 1: Closed and Mechanically Wedged Shut<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Step_2_Stem_Lifts_the_Core_Away_from_the_Seat\" >Step 2: Stem Lifts the Core Away from the Seat<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Step_3_Core_Rotates_Without_Seat_Contact\" >Step 3: Core Rotates Without Seat Contact<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Step_4_Full_Open_Flow_Path\" >Step 4: Full Open Flow Path<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Why_This_Motion_Matters_in_Real_Service\" >Why This Motion Matters in Real Service<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Parts_and_Internal_Structure\" >Orbit Valve Parts and Internal Structure<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Main_Parts_of_an_Orbit_Valve\" >Main Parts of an Orbit Valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_an_Orbit_Valve_Parts_Diagram_Should_Show\" >What an Orbit Valve Parts Diagram Should Show<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Replacement_Parts_Compatibility\" >Orbit Valve Replacement Parts &amp; Compatibility<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Standards_and_Project_Compliance_Options\" >Orbit Valve Standards and Project Compliance Options<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Common_Compliance_References_for_Orbit_Valve_Projects\" >Common Compliance References for Orbit Valve Projects<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Core_Design_Advantages_and_Compliance_Relevance\" >Core Design Advantages and Compliance Relevance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Important_Procurement_Note\" >Important Procurement Note<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_vs_Ball_Valve\" >Orbit Valve vs Ball Valve<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Quick_Selection_Guide_%E2%80%94_When_Is_an_Orbit_Valve_Worth_the_Premium\" >Quick Selection Guide \u2014 When Is an Orbit Valve Worth the Premium?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_vs_Plug_Valve\" >Orbit Valve vs Plug Valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_vs_Gate_Valve\" >Orbit Valve vs Gate Valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Applications_by_Service\" >Orbit Valve Applications by Service<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Gas_Transmission_and_Compressor_Stations\" >Gas Transmission and Compressor Stations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Molecular_Sieve_Dryer_Switching\" >Molecular Sieve Dryer Switching<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Meter_Isolation\" >Meter Isolation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Emergency_Shutdown_ESD_and_Critical_Block_Service\" >Emergency Shutdown (ESD) and Critical Block Service<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Product_Segregation_and_Block_Service\" >Product Segregation and Block Service<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Severe_Isolation_in_Oil_Gas_and_Petrochemical_Systems\" >Severe Isolation in Oil &amp; Gas and Petrochemical Systems<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#How_to_Select_an_Orbit_Valve\" >How to Select an Orbit Valve<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#1_Confirm_the_Service_Medium\" >1. Confirm the Service Medium<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#2_Confirm_Pressure_Class\" >2. Confirm Pressure Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#3_Confirm_Operating_Temperature\" >3. Confirm Operating Temperature<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#4_Confirm_Bore_Requirement\" >4. Confirm Bore Requirement<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#5_Confirm_End_Connection\" >5. Confirm End Connection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#6_Confirm_Actuation_Method\" >6. Confirm Actuation Method<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-36\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#7_Confirm_Compliance_Requirements\" >7. Confirm Compliance Requirements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-37\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#8_Confirm_Operation_Frequency\" >8. Confirm Operation Frequency<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-38\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#9_Confirm_the_Documentation_Package\" >9. Confirm the Documentation Package<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-39\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Purchaser_Documentation_Checklist\" >Purchaser Documentation Checklist<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-40\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_RFQ_Checklist\" >Orbit Valve RFQ Checklist<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-41\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Material_Selection_Guidance\" >Material Selection Guidance<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-42\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Actuators_and_Configuration\" >Orbit Valve Actuators and Configuration<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-43\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Key_Actuator_Selection_Points\" >Key Actuator Selection Points<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-44\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Packing_and_Low-Emission_Design\" >Orbit Valve Packing and Low-Emission Design<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-45\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Why_Packing_Matters\" >Why Packing Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-46\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Standard_Packing_vs_Low-Emission_Option\" >Standard Packing vs Low-Emission Option<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-47\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_Buyers_Should_State_in_the_RFQ\" >What Buyers Should State in the RFQ<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-48\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Typical_Orbit_Valve_Specifications\" >Typical Orbit Valve Specifications<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-49\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_Buyers_Usually_Need_Beyond_the_Table\" >What Buyers Usually Need Beyond the Table<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-50\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Diagrams_Drawings\" >Orbit Valve Diagrams &amp; Drawings<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-51\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Recommended_Download_Blocks\" >Recommended Download Blocks<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-52\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Orbit_Valve_Catalog_Datasheet_Drawing_O_M_Resources\" >Orbit Valve Catalog, Datasheet, Drawing &amp; O&amp;M Resources<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-53\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Instant_Download_Resources\" >Instant Download Resources<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-54\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Request-Based_Project_Resources\" >Request-Based Project Resources<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-55\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Recommended_Resource_Access_Logic\" >Recommended Resource Access Logic<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-56\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Why_Choose_NTGD_for_Orbit_Valve_Projects\" >Why Choose NTGD for Orbit Valve Projects<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-57\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_NTGD_Supports_in_an_Orbit_Valve_RFQ\" >What NTGD Supports in an Orbit Valve RFQ<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-58\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_Buyers_Usually_Care_About_Beyond_Price\" >What Buyers Usually Care About Beyond Price<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-59\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Global_Supply_and_Project_Support\" >Global Supply and Project Support<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-60\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Replacement_and_Compatibility_Support\" >Replacement and Compatibility Support<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-61\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Best_Way_to_Start_a_Replacement_Inquiry\" >Best Way to Start a Replacement Inquiry<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-62\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Frequently_Asked_Questions_About_Orbit_Valves\" >Frequently Asked Questions About Orbit Valves<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-63\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_is_an_orbit_valve\" >What is an orbit valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-64\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Why_is_an_orbit_valve_called_a_rising_stem_ball_valve\" >Why is an orbit valve called a rising stem ball valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-65\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_is_the_difference_between_an_orbit_valve_and_a_ball_valve\" >What is the difference between an orbit valve and a ball valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-66\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_does_an_orbit_valve_parts_diagram_include\" >What does an orbit valve parts diagram include?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-67\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Why_are_orbit_valves_more_expensive_than_conventional_ball_valves\" >Why are orbit valves more expensive than conventional ball valves?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-68\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Are_orbit_valves_available_with_fire-safe_design\" >Are orbit valves available with fire-safe design?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-69\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_is_the_difference_between_an_orbit_valve_and_a_gate_valve\" >What is the difference between an orbit valve and a gate valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-70\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Can_orbit_valves_be_supplied_with_replacement_parts\" >Can orbit valves be supplied with replacement parts?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-71\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#What_documents_should_be_requested_before_ordering_an_orbit_valve\" >What documents should be requested before ordering an orbit valve?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-72\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Where_are_orbit_valves_typically_used\" >Where are orbit valves typically used?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-73\" href=\"https:\/\/ntgdvalve.com\/ru\/orbit-valve\/#Request_Support_for_Your_Orbit_Valve_Project\" >Request Support for Your Orbit Valve Project<\/a><\/li><\/ul><\/nav><\/div>\n<h2 data-section-id=\"v4phfv\" data-start=\"1483\" data-end=\"1526\"><span class=\"ez-toc-section\" id=\"What_Is_an_Orbit_Rising_Stem_Ball_Valve\"><\/span>What Is an Orbit Rising Stem Ball Valve?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"attachment_8168\" aria-describedby=\"caption-attachment-8168\" style=\"width: 1536px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-8168\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-manual-handwheel-product-photo.png\" alt=\"Manual orbit valve with handwheel showing rising stem design and flanged pipeline connection\" width=\"1536\" height=\"1024\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-manual-handwheel-product-photo.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-manual-handwheel-product-photo-768x512.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-manual-handwheel-product-photo-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-manual-handwheel-product-photo-600x400.png 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><figcaption id=\"caption-attachment-8168\" class=\"wp-caption-text\">Manual orbit valve with handwheel used for pipeline isolation and high reliability shutoff.<\/figcaption><\/figure>\n<p data-start=\"1528\" data-end=\"1920\">An orbit rising stem ball valve is a quarter-turn isolation valve that combines a ball-type shutoff element with a <strong data-start=\"1643\" data-end=\"1672\">guided rising stem motion<\/strong>. Its defining feature is that the sealing surfaces are separated before rotation begins. That difference is critical in applications where repeated cycling, seat wear, torque increase, or long-term shutoff stability become real operating concerns.<\/p>\n<p data-start=\"1922\" data-end=\"2010\">In practical procurement terms, orbit valves are selected when the application requires:<\/p>\n<ul data-start=\"2012\" data-end=\"2269\">\n<li data-section-id=\"ph70up\" data-start=\"2012\" data-end=\"2057\">\n<p data-start=\"2014\" data-end=\"2057\">reliable shutoff in critical isolation duty<\/p>\n<\/li>\n<li data-section-id=\"1xfgxxs\" data-start=\"2058\" data-end=\"2103\">\n<p data-start=\"2060\" data-end=\"2103\">lower seat wear in repeated cycling service<\/p>\n<\/li>\n<li data-section-id=\"1m1uf3j\" data-start=\"2104\" data-end=\"2143\">\n<p data-start=\"2106\" data-end=\"2143\">more stable torque behavior over time<\/p>\n<\/li>\n<li data-section-id=\"16h3x3e\" data-start=\"2144\" data-end=\"2207\">\n<p data-start=\"2146\" data-end=\"2207\">better suitability for severe gas isolation or switching duty<\/p>\n<\/li>\n<li data-section-id=\"ttnpoe\" data-start=\"2208\" data-end=\"2269\">\n<p data-start=\"2210\" data-end=\"2269\">engineered selection rather than commodity valve purchasing<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2271\" data-end=\"2380\">This is why orbit valves are widely associated with <strong data-start=\"2323\" data-end=\"2353\">critical isolation service<\/strong>, not just general shutoff.<\/p>\n<h3 data-section-id=\"qrh8h1\" data-start=\"2382\" data-end=\"2423\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_vs_Rising_Stem_Ball_Valve\"><\/span>Orbit Valve vs Rising Stem Ball Valve<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"2425\" data-end=\"2671\">In engineering and procurement language, <strong data-start=\"2466\" data-end=\"2481\">orbit valve<\/strong> and <strong data-start=\"2486\" data-end=\"2512\">rising stem ball valve<\/strong> are often used interchangeably. The latter term is more descriptive because it refers directly to the motion of the stem and closure element during operation.<\/p>\n<h3 data-section-id=\"3y7cz2\" data-start=\"2673\" data-end=\"2705\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_vs_Orbital_Valve\"><\/span>Orbit Valve vs Orbital Valve<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"2707\" data-end=\"2925\">Some buyers search for <strong data-start=\"2730\" data-end=\"2747\">orbital valve<\/strong> when they actually mean orbit valve. On this page, we are referring specifically to the industrial <strong data-start=\"2847\" data-end=\"2879\">orbit rising stem ball valve<\/strong> used for pipeline and process isolation duty.<\/p>\n<hr data-start=\"2927\" data-end=\"2930\" \/>\n<h2 data-section-id=\"19bf0iq\" data-start=\"2932\" data-end=\"2959\"><span class=\"ez-toc-section\" id=\"How_an_Orbit_Valve_Works\"><\/span>How an Orbit Valve Works<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"attachment_8162\" aria-describedby=\"caption-attachment-8162\" style=\"width: 1536px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-8162\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-working-principle-diagram.png\" alt=\"Orbit ball valve working principle diagram showing lift then turn motion and full open flow path\" width=\"1536\" height=\"1024\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-working-principle-diagram.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-working-principle-diagram-768x512.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-working-principle-diagram-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-working-principle-diagram-600x400.png 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><figcaption id=\"caption-attachment-8162\" class=\"wp-caption-text\">Working principle of an orbit valve showing the lift and rotation motion during operation.<\/figcaption><\/figure>\n<p data-start=\"2961\" data-end=\"3155\">The working principle of an orbit valve is best understood as a four-step operating sequence. The value of this design lies in <strong data-start=\"3088\" data-end=\"3122\">how the valve closes and opens<\/strong>, not just in what it looks like.<\/p>\n<h3 data-section-id=\"o4jlzm\" data-start=\"3157\" data-end=\"3204\"><span class=\"ez-toc-section\" id=\"Step_1_Closed_and_Mechanically_Wedged_Shut\"><\/span>Step 1: Closed and Mechanically Wedged Shut<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"3206\" data-end=\"3394\">In the fully closed position, the core is pressed firmly against the seat. The stem and guide mechanism hold the closure element in a wedged shut position that provides positive isolation.<\/p>\n<p data-start=\"3396\" data-end=\"3685\"><strong data-start=\"3396\" data-end=\"3427\">Image block recommendation:<\/strong> Step 1 micro-diagram showing core in full contact with seat<br data-start=\"3487\" data-end=\"3490\" \/><strong data-start=\"3490\" data-end=\"3502\">Caption:<\/strong> <em data-start=\"3503\" data-end=\"3593\">Closed position \u2014 the core is mechanically wedged against the seat for positive shutoff.<\/em><br data-start=\"3593\" data-end=\"3596\" \/><strong data-start=\"3596\" data-end=\"3619\">Suggested alt text:<\/strong> <code data-start=\"3620\" data-end=\"3685\">orbit-rising-stem-ball-valve-closed-position-mechanical-wedging<\/code><\/p>\n<h3 data-section-id=\"177rzqv\" data-start=\"3687\" data-end=\"3737\"><span class=\"ez-toc-section\" id=\"Step_2_Stem_Lifts_the_Core_Away_from_the_Seat\"><\/span>Step 2: Stem Lifts the Core Away from the Seat<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"3739\" data-end=\"3965\">When the valve begins to open, the stem rises through its guided motion and lifts the core clear of the seat before rotation starts. This lift-off action is the reason orbit valves are known for <strong data-start=\"3934\" data-end=\"3964\">non-rubbing sealing motion<\/strong>.<\/p>\n<p data-start=\"3967\" data-end=\"4234\"><strong data-start=\"3967\" data-end=\"3998\">Image block recommendation:<\/strong> Step 2 micro-diagram showing visible gap between core and seat<br data-start=\"4061\" data-end=\"4064\" \/><strong data-start=\"4064\" data-end=\"4076\">Caption:<\/strong> <em data-start=\"4077\" data-end=\"4166\">Lift-off stage \u2014 the core moves away from the seat before rotation, preventing rubbing.<\/em><br data-start=\"4166\" data-end=\"4169\" \/><strong data-start=\"4169\" data-end=\"4192\">Suggested alt text:<\/strong> <code data-start=\"4193\" data-end=\"4234\">orbit-valve-lift-off-no-rubbing-diagram<\/code><\/p>\n<h3 data-section-id=\"1fv45wj\" data-start=\"4236\" data-end=\"4281\"><span class=\"ez-toc-section\" id=\"Step_3_Core_Rotates_Without_Seat_Contact\"><\/span>Step 3: Core Rotates Without Seat Contact<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"4283\" data-end=\"4509\">With the sealing surfaces already separated, the core rotates to the open position without scraping against the seat. This differs fundamentally from a conventional ball valve, where the ball rotates in contact with the seats.<\/p>\n<p data-start=\"4511\" data-end=\"4780\"><strong data-start=\"4511\" data-end=\"4542\">Image block recommendation:<\/strong> Step 3 micro-diagram showing 90-degree rotation in lifted position<br data-start=\"4609\" data-end=\"4612\" \/><strong data-start=\"4612\" data-end=\"4624\">Caption:<\/strong> <em data-start=\"4625\" data-end=\"4702\">Rotation stage \u2014 the core turns without seat contact, minimizing seat wear.<\/em><br data-start=\"4702\" data-end=\"4705\" \/><strong data-start=\"4705\" data-end=\"4728\">Suggested alt text:<\/strong> <code data-start=\"4729\" data-end=\"4780\">orbit-valve-rotation-without-seat-contact-diagram<\/code><\/p>\n<h3 data-section-id=\"rzm7nm\" data-start=\"4782\" data-end=\"4813\"><span class=\"ez-toc-section\" id=\"Step_4_Full_Open_Flow_Path\"><\/span>Step 4: Full Open Flow Path<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"4815\" data-end=\"5068\">In the fully open position, the valve provides the intended flow path according to its bore configuration. During closing, the sequence reverses: the core rotates while clear of the seat, then wedges back into the shut position at the end of the stroke.<\/p>\n<p data-start=\"5070\" data-end=\"5318\"><strong data-start=\"5070\" data-end=\"5101\">Image block recommendation:<\/strong> Step 4 micro-diagram showing open flow arrows<br data-start=\"5147\" data-end=\"5150\" \/><strong data-start=\"5150\" data-end=\"5162\">Caption:<\/strong> <em data-start=\"5163\" data-end=\"5250\">Full open position \u2014 flow passes through the valve after the core completes rotation.<\/em><br data-start=\"5250\" data-end=\"5253\" \/><strong data-start=\"5253\" data-end=\"5276\">Suggested alt text:<\/strong> <code data-start=\"5277\" data-end=\"5318\">orbit-valve-full-open-flow-path-diagram<\/code><\/p>\n<h3 data-section-id=\"1qe651s\" data-start=\"5320\" data-end=\"5363\"><span class=\"ez-toc-section\" id=\"Why_This_Motion_Matters_in_Real_Service\"><\/span>Why This Motion Matters in Real Service<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"5365\" data-end=\"5681\">In severe isolation duty, valves do not usually fail because they cannot close once. They fail because <strong data-start=\"5468\" data-end=\"5529\">repeated operation gradually damages the sealing surfaces<\/strong>, increases leakage risk, or changes torque behavior. The orbit valve mechanism directly addresses that failure mode by separating lifting and rotation.<\/p>\n<hr data-start=\"5878\" data-end=\"5881\" \/>\n<h2 data-section-id=\"1ghdmsy\" data-start=\"5883\" data-end=\"5926\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Parts_and_Internal_Structure\"><\/span>Orbit Valve Parts and Internal Structure<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"attachment_8166\" aria-describedby=\"caption-attachment-8166\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-8166\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-cutaway-cross-section-diagram.png\" alt=\"Orbit ball valve cross section diagram showing trunnion supported core and metal sealing seat\" width=\"1024\" height=\"1536\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-cutaway-cross-section-diagram.png 1024w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-cutaway-cross-section-diagram-768x1152.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-cutaway-cross-section-diagram-8x12.png 8w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-cutaway-cross-section-diagram-600x900.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-8166\" class=\"wp-caption-text\">Cutaway cross section of an orbit valve highlighting the internal flow path and sealing design.<\/figcaption><\/figure>\n<p data-start=\"5928\" data-end=\"6105\">Understanding orbit valve parts is important not only for design review, but also for <strong data-start=\"6014\" data-end=\"6104\">selection, maintenance planning, replacement parts support, and documentation approval<\/strong>.<\/p>\n<h3 data-section-id=\"xo1e4l\" data-start=\"6107\" data-end=\"6139\"><span class=\"ez-toc-section\" id=\"Main_Parts_of_an_Orbit_Valve\"><\/span>Main Parts of an Orbit Valve<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"6141\" data-end=\"7736\" data-extentions-extra-tablecapture-id=\"404939\">\n<thead data-start=\"6141\" data-end=\"6190\">\n<tr data-start=\"6141\" data-end=\"6190\">\n<th class=\"\" data-start=\"6141\" data-end=\"6148\" data-col-size=\"sm\">Part<\/th>\n<th class=\"\" data-start=\"6148\" data-end=\"6159\" data-col-size=\"md\">Function<\/th>\n<th class=\"\" data-start=\"6159\" data-end=\"6190\" data-col-size=\"lg\">Why It Matters in Selection<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"6205\" data-end=\"7736\">\n<tr data-start=\"6205\" data-end=\"6434\">\n<td data-start=\"6205\" data-end=\"6218\" data-col-size=\"sm\">Valve Body<\/td>\n<td data-start=\"6218\" data-end=\"6274\" data-col-size=\"md\">Pressure-containing shell housing the valve internals<\/td>\n<td data-start=\"6274\" data-end=\"6434\" data-col-size=\"lg\">Determines pressure class, corrosion resistance, and end connection type. Buyers must confirm whether body material and rating match the service conditions.<\/td>\n<\/tr>\n<tr data-start=\"6435\" data-end=\"6576\">\n<td data-start=\"6435\" data-end=\"6458\" data-col-size=\"sm\">Bonnet \/ Top Closure<\/td>\n<td data-start=\"6458\" data-end=\"6499\" data-col-size=\"md\">Provides access to internal components<\/td>\n<td data-start=\"6499\" data-end=\"6576\" data-col-size=\"lg\">Influences serviceability, maintenance philosophy, and inspection access.<\/td>\n<\/tr>\n<tr data-start=\"6577\" data-end=\"6723\">\n<td data-start=\"6577\" data-end=\"6584\" data-col-size=\"sm\">Stem<\/td>\n<td data-start=\"6584\" data-end=\"6634\" data-col-size=\"md\">Transfers actuator or manual motion to the core<\/td>\n<td data-start=\"6634\" data-end=\"6723\" data-col-size=\"lg\">Critical to the lift-and-turn sequence, torque transmission, and operating stability.<\/td>\n<\/tr>\n<tr data-start=\"6724\" data-end=\"6855\">\n<td data-start=\"6724\" data-end=\"6749\" data-col-size=\"sm\">Core \/ Closure Element<\/td>\n<td data-start=\"6749\" data-end=\"6772\" data-col-size=\"md\">Main shutoff element<\/td>\n<td data-start=\"6772\" data-end=\"6855\" data-col-size=\"lg\">Defines shutoff behavior, wear characteristics, and severe-service suitability.<\/td>\n<\/tr>\n<tr data-start=\"6856\" data-end=\"7001\">\n<td data-start=\"6856\" data-end=\"6863\" data-col-size=\"sm\">Seat<\/td>\n<td data-start=\"6863\" data-end=\"6891\" data-col-size=\"md\">Primary sealing interface<\/td>\n<td data-start=\"6891\" data-end=\"7001\" data-col-size=\"lg\">Affects shutoff integrity, wear tendency, and compatibility with the medium and operating cycle frequency.<\/td>\n<\/tr>\n<tr data-start=\"7002\" data-end=\"7132\">\n<td data-start=\"7002\" data-end=\"7027\" data-col-size=\"sm\">Guide Pin \/ Guide Slot<\/td>\n<td data-start=\"7027\" data-end=\"7067\" data-col-size=\"md\">Controls rising and rotating movement<\/td>\n<td data-start=\"7067\" data-end=\"7132\" data-col-size=\"lg\">Central to motion accuracy and long-term shutoff consistency.<\/td>\n<\/tr>\n<tr data-start=\"7133\" data-end=\"7286\">\n<td data-start=\"7133\" data-end=\"7143\" data-col-size=\"sm\">Packing<\/td>\n<td data-start=\"7143\" data-end=\"7195\" data-col-size=\"md\">Seals around the stem to prevent external leakage<\/td>\n<td data-start=\"7195\" data-end=\"7286\" data-col-size=\"lg\">Important where emissions control, gas service, or low-leakage performance is required.<\/td>\n<\/tr>\n<tr data-start=\"7287\" data-end=\"7417\">\n<td data-start=\"7287\" data-end=\"7309\" data-col-size=\"sm\">Bearings \/ Bushings<\/td>\n<td data-start=\"7309\" data-end=\"7348\" data-col-size=\"md\">Support movement and reduce friction<\/td>\n<td data-start=\"7348\" data-end=\"7417\" data-col-size=\"lg\">Affect torque smoothness, wear control, and mechanical stability.<\/td>\n<\/tr>\n<tr data-start=\"7418\" data-end=\"7572\">\n<td data-start=\"7418\" data-end=\"7439\" data-col-size=\"sm\">Actuator Interface<\/td>\n<td data-start=\"7439\" data-end=\"7491\" data-col-size=\"md\">Connects the valve to powered or manual actuation<\/td>\n<td data-start=\"7491\" data-end=\"7572\" data-col-size=\"lg\">Important for automation philosophy, shutdown logic, and control integration.<\/td>\n<\/tr>\n<tr data-start=\"7573\" data-end=\"7736\">\n<td data-start=\"7573\" data-end=\"7602\" data-col-size=\"sm\">Fire-Safe Sealing Elements<\/td>\n<td data-start=\"7602\" data-end=\"7645\" data-col-size=\"md\">Provide backup sealing in fire scenarios<\/td>\n<td data-start=\"7645\" data-end=\"7736\" data-col-size=\"lg\">Relevant in hydrocarbon and fire-risk applications where fire-safe design is specified.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"22oitu\" data-start=\"7738\" data-end=\"7787\"><span class=\"ez-toc-section\" id=\"What_an_Orbit_Valve_Parts_Diagram_Should_Show\"><\/span>What an Orbit Valve Parts Diagram Should Show<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<figure id=\"attachment_8169\" aria-describedby=\"caption-attachment-8169\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8169\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-internal-structure-cutaway-diagram.png\" alt=\"Orbit valve internal structure diagram showing stem packing seat insert and sealing components\" width=\"1024\" height=\"1536\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-internal-structure-cutaway-diagram.png 1024w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-internal-structure-cutaway-diagram-768x1152.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-internal-structure-cutaway-diagram-8x12.png 8w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-internal-structure-cutaway-diagram-600x900.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-8169\" class=\"wp-caption-text\">Internal structure of an orbit valve illustrating major sealing and mechanical components.<\/figcaption><\/figure>\n<p data-start=\"7789\" data-end=\"7848\">A useful orbit valve parts diagram should clearly identify:<\/p>\n<ul data-start=\"7850\" data-end=\"7963\">\n<li data-section-id=\"1j3eu48\" data-start=\"7850\" data-end=\"7856\">\n<p data-start=\"7852\" data-end=\"7856\">body<\/p>\n<\/li>\n<li data-section-id=\"1c4ur10\" data-start=\"7857\" data-end=\"7865\">\n<p data-start=\"7859\" data-end=\"7865\">bonnet<\/p>\n<\/li>\n<li data-section-id=\"1j3q86f\" data-start=\"7866\" data-end=\"7872\">\n<p data-start=\"7868\" data-end=\"7872\">stem<\/p>\n<\/li>\n<li data-section-id=\"1j3dzir\" data-start=\"7873\" data-end=\"7879\">\n<p data-start=\"7875\" data-end=\"7879\">core<\/p>\n<\/li>\n<li data-section-id=\"1j3qmgb\" data-start=\"7880\" data-end=\"7886\">\n<p data-start=\"7882\" data-end=\"7886\">seat<\/p>\n<\/li>\n<li data-section-id=\"u35c7l\" data-start=\"7887\" data-end=\"7896\">\n<p data-start=\"7889\" data-end=\"7896\">packing<\/p>\n<\/li>\n<li data-section-id=\"318pk9\" data-start=\"7897\" data-end=\"7914\">\n<p data-start=\"7899\" data-end=\"7914\">guide mechanism<\/p>\n<\/li>\n<li data-section-id=\"1gf691r\" data-start=\"7915\" data-end=\"7925\">\n<p data-start=\"7917\" data-end=\"7925\">bearings<\/p>\n<\/li>\n<li data-section-id=\"bvmsg6\" data-start=\"7926\" data-end=\"7946\">\n<p data-start=\"7928\" data-end=\"7946\">actuator interface<\/p>\n<\/li>\n<li data-section-id=\"husykf\" data-start=\"7947\" data-end=\"7963\">\n<p data-start=\"7949\" data-end=\"7963\">flow direction<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"7965\" data-end=\"8123\">For engineers and maintenance teams, this is more valuable than a generic product photo because it helps clarify <strong data-start=\"8078\" data-end=\"8122\">how the shutoff structure actually works<\/strong>.<\/p>\n<h3 data-section-id=\"1ref6gu\" data-start=\"8371\" data-end=\"8420\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Replacement_Parts_Compatibility\"><\/span>Orbit Valve Replacement Parts &amp; Compatibility<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"8422\" data-end=\"8610\">Buyers searching <strong data-start=\"8439\" data-end=\"8460\">orbit valve parts<\/strong> are often not looking for a definition. They are looking for <strong data-start=\"8522\" data-end=\"8609\">replacement seats, packing, guide parts, gaskets, or maintenance-related components<\/strong>.<\/p>\n<p data-start=\"8612\" data-end=\"8739\">NTGD can support replacement parts inquiries for orbit rising stem ball valves based on available valve information, including:<\/p>\n<ul data-start=\"8741\" data-end=\"8901\">\n<li data-section-id=\"njohet\" data-start=\"8741\" data-end=\"8753\">\n<p data-start=\"8743\" data-end=\"8753\">valve size<\/p>\n<\/li>\n<li data-section-id=\"ch03cz\" data-start=\"8754\" data-end=\"8770\">\n<p data-start=\"8756\" data-end=\"8770\">pressure class<\/p>\n<\/li>\n<li data-section-id=\"14p8eoj\" data-start=\"8771\" data-end=\"8786\">\n<p data-start=\"8773\" data-end=\"8786\">body material<\/p>\n<\/li>\n<li data-section-id=\"1fmj3n5\" data-start=\"8787\" data-end=\"8803\">\n<p data-start=\"8789\" data-end=\"8803\">end connection<\/p>\n<\/li>\n<li data-section-id=\"1xqtmku\" data-start=\"8804\" data-end=\"8820\">\n<p data-start=\"8806\" data-end=\"8820\">actuation type<\/p>\n<\/li>\n<li data-section-id=\"1im8rwz\" data-start=\"8821\" data-end=\"8837\">\n<p data-start=\"8823\" data-end=\"8837\">nameplate data<\/p>\n<\/li>\n<li data-section-id=\"16e7imi\" data-start=\"8838\" data-end=\"8860\">\n<p data-start=\"8840\" data-end=\"8860\">drawing or datasheet<\/p>\n<\/li>\n<li data-section-id=\"1ru3o8u\" data-start=\"8861\" data-end=\"8901\">\n<p data-start=\"8863\" data-end=\"8901\">installed valve photos, when available<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"8903\" data-end=\"8945\">Typical replacement inquiries may involve:<\/p>\n<ul data-start=\"8947\" data-end=\"9066\">\n<li data-section-id=\"1qed4z7\" data-start=\"8947\" data-end=\"8964\">\n<p data-start=\"8949\" data-end=\"8964\">seat assemblies<\/p>\n<\/li>\n<li data-section-id=\"1p25w80\" data-start=\"8965\" data-end=\"8979\">\n<p data-start=\"8967\" data-end=\"8979\">packing sets<\/p>\n<\/li>\n<li data-section-id=\"my8dw4\" data-start=\"8980\" data-end=\"8989\">\n<p data-start=\"8982\" data-end=\"8989\">gaskets<\/p>\n<\/li>\n<li data-section-id=\"1x8hist\" data-start=\"8990\" data-end=\"9022\">\n<p data-start=\"8992\" data-end=\"9022\">guide pins or guide components<\/p>\n<\/li>\n<li data-section-id=\"16ctbwh\" data-start=\"9023\" data-end=\"9043\">\n<p data-start=\"9025\" data-end=\"9043\">stem-related parts<\/p>\n<\/li>\n<li data-section-id=\"17lkfwl\" data-start=\"9044\" data-end=\"9066\">\n<p data-start=\"9046\" data-end=\"9066\">actuator accessories<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"9068\" data-end=\"9181\">Replacement support should always be reviewed against actual installed valve data rather than nominal size alone.<\/p>\n<p data-start=\"9183\" data-end=\"9321\"><strong data-start=\"9183\" data-end=\"9191\">CTA:<\/strong> Request Orbit Valve Parts Review | Ask for Parts List Support<br data-start=\"9253\" data-end=\"9256\" \/><strong data-start=\"9256\" data-end=\"9280\">Download suggestion:<\/strong> Download Orbit Valve Parts Diagram (PDF)<\/p>\n<hr data-start=\"9323\" data-end=\"9326\" \/>\n<h2 data-section-id=\"5kq9jo\" data-start=\"9328\" data-end=\"9383\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Standards_and_Project_Compliance_Options\"><\/span>Orbit Valve Standards and Project Compliance Options<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"9385\" data-end=\"9592\">In industrial valve procurement, design explanation alone is not enough, especially when project approval is tied to standards such as <a href=\"https:\/\/www.api.org\/products-and-services\/standards\/important-standards-announcements\/spec6d\" target=\"_blank\" rel=\"noopener\">API Spec 6D<\/a>. Buyers also need to know whether the valve can be supplied to the <strong data-start=\"9524\" data-end=\"9591\">required standards, inspection scope, and documentation package<\/strong>.<\/p>\n<h3 data-section-id=\"16eyd21\" data-start=\"9594\" data-end=\"9651\"><span class=\"ez-toc-section\" id=\"Common_Compliance_References_for_Orbit_Valve_Projects\"><\/span>Common Compliance References for Orbit Valve Projects<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"9653\" data-end=\"10897\" data-extentions-extra-tablecapture-id=\"241213\">\n<thead data-start=\"9653\" data-end=\"9756\">\n<tr data-start=\"9653\" data-end=\"9756\">\n<th class=\"\" data-start=\"9653\" data-end=\"9678\" data-col-size=\"sm\">Feature or Requirement<\/th>\n<th class=\"\" data-start=\"9678\" data-end=\"9708\" data-col-size=\"sm\">Common Standard \/ Reference<\/th>\n<th class=\"\" data-start=\"9708\" data-end=\"9735\" data-col-size=\"md\">Why It Matters to Buyers<\/th>\n<th class=\"\" data-start=\"9735\" data-end=\"9756\" data-col-size=\"md\">NTGD Supply Basis<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"9775\" data-end=\"10897\">\n<tr data-start=\"9775\" data-end=\"9929\">\n<td data-start=\"9775\" data-end=\"9799\" data-col-size=\"sm\">Pipeline valve design<\/td>\n<td data-start=\"9799\" data-end=\"9808\" data-col-size=\"sm\">API 6D<\/td>\n<td data-start=\"9808\" data-end=\"9874\" data-col-size=\"md\">Often required for pipeline and critical isolation applications<\/td>\n<td data-start=\"9874\" data-end=\"9929\" data-col-size=\"md\">Can be reviewed and supplied to project requirement<\/td>\n<\/tr>\n<tr data-start=\"9930\" data-end=\"10078\">\n<td data-start=\"9930\" data-end=\"9966\" data-col-size=\"sm\">Pressure-temperature design basis<\/td>\n<td data-start=\"9966\" data-end=\"9980\" data-col-size=\"sm\">ASME B16.34<\/td>\n<td data-start=\"9980\" data-end=\"10023\" data-col-size=\"md\">Defines design envelope and rating logic<\/td>\n<td data-start=\"10023\" data-end=\"10078\" data-col-size=\"md\">Can be reviewed and supplied to project requirement<\/td>\n<\/tr>\n<tr data-start=\"10079\" data-end=\"10183\">\n<td data-start=\"10079\" data-end=\"10100\" data-col-size=\"sm\">Flanged dimensions<\/td>\n<td data-start=\"10100\" data-end=\"10113\" data-col-size=\"sm\">ASME B16.5<\/td>\n<td data-start=\"10113\" data-end=\"10144\" data-col-size=\"md\">Ensures piping compatibility<\/td>\n<td data-start=\"10144\" data-end=\"10183\" data-col-size=\"md\">Available per project configuration<\/td>\n<\/tr>\n<tr data-start=\"10184\" data-end=\"10294\">\n<td data-start=\"10184\" data-end=\"10204\" data-col-size=\"sm\">Butt-welding ends<\/td>\n<td data-start=\"10204\" data-end=\"10218\" data-col-size=\"sm\">ASME B16.25<\/td>\n<td data-start=\"10218\" data-end=\"10255\" data-col-size=\"md\">Required for welded piping systems<\/td>\n<td data-start=\"10255\" data-end=\"10294\" data-col-size=\"md\">Available per project configuration<\/td>\n<\/tr>\n<tr data-start=\"10295\" data-end=\"10430\">\n<td data-start=\"10295\" data-end=\"10314\" data-col-size=\"sm\">Fire-safe design<\/td>\n<td data-start=\"10314\" data-end=\"10334\" data-col-size=\"sm\">API 607 \/ API 6FA<\/td>\n<td data-start=\"10334\" data-end=\"10384\" data-col-size=\"md\">Important for hydrocarbon and fire-risk service<\/td>\n<td data-start=\"10384\" data-end=\"10430\" data-col-size=\"md\">Optional, subject to project specification<\/td>\n<\/tr>\n<tr data-start=\"10431\" data-end=\"10591\">\n<td data-start=\"10431\" data-end=\"10459\" data-col-size=\"sm\">Fugitive emission control<\/td>\n<td data-start=\"10459\" data-end=\"10483\" data-col-size=\"sm\">ISO 15848-1 \/ API 622<\/td>\n<td data-start=\"10483\" data-end=\"10533\" data-col-size=\"md\">Relevant where low external leakage is required<\/td>\n<td data-start=\"10533\" data-end=\"10591\" data-col-size=\"md\">Optional configuration, subject to project requirement<\/td>\n<\/tr>\n<tr data-start=\"10592\" data-end=\"10732\">\n<td data-start=\"10592\" data-end=\"10623\" data-col-size=\"sm\">Sour service material review<\/td>\n<td data-start=\"10623\" data-end=\"10649\" data-col-size=\"sm\">NACE MR0175 \/ ISO 15156<\/td>\n<td data-start=\"10649\" data-end=\"10693\" data-col-size=\"md\">Important for H2S-containing applications<\/td>\n<td data-start=\"10693\" data-end=\"10732\" data-col-size=\"md\">Optional, subject to service review<\/td>\n<\/tr>\n<tr data-start=\"10733\" data-end=\"10897\">\n<td data-start=\"10733\" data-end=\"10758\" data-col-size=\"sm\">Inspection and testing<\/td>\n<td data-start=\"10758\" data-end=\"10799\" data-col-size=\"sm\">Project-specific QA \/ ITP \/ test plans<\/td>\n<td data-start=\"10799\" data-end=\"10851\" data-col-size=\"md\">Required for quality control and final acceptance<\/td>\n<td data-start=\"10851\" data-end=\"10897\" data-col-size=\"md\">Documentation scope available upon request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"1jtpa0w\" data-start=\"10899\" data-end=\"10950\"><span class=\"ez-toc-section\" id=\"Core_Design_Advantages_and_Compliance_Relevance\"><\/span>Core Design Advantages and Compliance Relevance<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"10952\" data-end=\"11069\">The value of an orbit valve is not only in the motion itself, but in how that motion relates to project requirements:<\/p>\n<ul data-start=\"11071\" data-end=\"11572\">\n<li data-section-id=\"9l8n2w\" data-start=\"11071\" data-end=\"11158\">\n<p data-start=\"11073\" data-end=\"11158\"><strong data-start=\"11073\" data-end=\"11102\">non-rubbing shutoff logic<\/strong> is relevant where long-term sealing reliability matters<\/p>\n<\/li>\n<li data-section-id=\"olxruf\" data-start=\"11159\" data-end=\"11266\">\n<p data-start=\"11161\" data-end=\"11266\"><strong data-start=\"11161\" data-end=\"11186\">packing configuration<\/strong> is important where emissions control or gas service is a procurement checkpoint<\/p>\n<\/li>\n<li data-section-id=\"yq8dn5\" data-start=\"11267\" data-end=\"11383\">\n<p data-start=\"11269\" data-end=\"11383\"><strong data-start=\"11269\" data-end=\"11290\">fire-safe options<\/strong> matter in hydrocarbon systems where post-fire sealing integrity is part of the specification<\/p>\n<\/li>\n<li data-section-id=\"1g7p8i6\" data-start=\"11384\" data-end=\"11455\">\n<p data-start=\"11386\" data-end=\"11455\"><strong data-start=\"11386\" data-end=\"11405\">material review<\/strong> matters in corrosive or sour service applications<\/p>\n<\/li>\n<li data-section-id=\"1qqeenb\" data-start=\"11456\" data-end=\"11572\">\n<p data-start=\"11458\" data-end=\"11572\"><strong data-start=\"11458\" data-end=\"11481\">testing and records<\/strong> matter because many project delays happen at documentation review, not at factory assembly<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"16yd6lq\" data-start=\"11574\" data-end=\"11604\"><span class=\"ez-toc-section\" id=\"Important_Procurement_Note\"><\/span>Important Procurement Note<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"11606\" data-end=\"11714\">The correct way to specify an orbit valve is not to request only \u201corbit valve.\u201d A proper RFQ should confirm:<\/p>\n<ul data-start=\"11716\" data-end=\"11909\">\n<li data-section-id=\"12747oe\" data-start=\"11716\" data-end=\"11737\">\n<p data-start=\"11718\" data-end=\"11737\">applicable standard<\/p>\n<\/li>\n<li data-section-id=\"ch03cz\" data-start=\"11738\" data-end=\"11754\">\n<p data-start=\"11740\" data-end=\"11754\">pressure class<\/p>\n<\/li>\n<li data-section-id=\"m6u71l\" data-start=\"11755\" data-end=\"11780\">\n<p data-start=\"11757\" data-end=\"11780\">body and trim materials<\/p>\n<\/li>\n<li data-section-id=\"dcq76b\" data-start=\"11781\" data-end=\"11804\">\n<p data-start=\"11783\" data-end=\"11804\">fire-safe requirement<\/p>\n<\/li>\n<li data-section-id=\"1fnoogd\" data-start=\"11805\" data-end=\"11828\">\n<p data-start=\"11807\" data-end=\"11828\">emissions requirement<\/p>\n<\/li>\n<li data-section-id=\"1vq7rop\" data-start=\"11829\" data-end=\"11850\">\n<p data-start=\"11831\" data-end=\"11850\">end connection type<\/p>\n<\/li>\n<li data-section-id=\"13y4fbd\" data-start=\"11851\" data-end=\"11869\">\n<p data-start=\"11853\" data-end=\"11869\">actuation method<\/p>\n<\/li>\n<li data-section-id=\"11eb9w\" data-start=\"11870\" data-end=\"11885\">\n<p data-start=\"11872\" data-end=\"11885\">testing scope<\/p>\n<\/li>\n<li data-section-id=\"1qorcdc\" data-start=\"11886\" data-end=\"11909\">\n<p data-start=\"11888\" data-end=\"11909\">documentation package<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"11911\" data-end=\"12102\">Standards should not be treated as marketing labels. They are <strong data-start=\"11973\" data-end=\"12012\">procurement and approval parameters<\/strong> that should be confirmed before quotation finalization, not after purchase order release.<\/p>\n<hr data-start=\"12197\" data-end=\"12200\" \/>\n<h2 data-section-id=\"r8uh29\" data-start=\"12202\" data-end=\"12230\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_vs_Ball_Valve\"><\/span>Orbit Valve vs Ball Valve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"12232\" data-end=\"12370\">Orbit valves are often discussed alongside ball valves, but the two are not interchangeable in every service from a lifecycle perspective.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"12372\" data-end=\"13248\" data-extentions-extra-tablecapture-id=\"509315\">\n<thead data-start=\"12372\" data-end=\"12431\">\n<tr data-start=\"12372\" data-end=\"12431\">\n<th class=\"\" data-start=\"12372\" data-end=\"12390\" data-col-size=\"sm\">Comparison Item<\/th>\n<th class=\"\" data-start=\"12390\" data-end=\"12404\" data-col-size=\"md\">Orbit Valve<\/th>\n<th class=\"\" data-start=\"12404\" data-end=\"12431\" data-col-size=\"md\">Conventional Ball Valve<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"12446\" data-end=\"13248\">\n<tr data-start=\"12446\" data-end=\"12549\">\n<td data-start=\"12446\" data-end=\"12473\" data-col-size=\"sm\">Opening \/ closing motion<\/td>\n<td data-start=\"12473\" data-end=\"12509\" data-col-size=\"md\">Lift-then-turn rising stem motion<\/td>\n<td data-start=\"12509\" data-end=\"12549\" data-col-size=\"md\">Rotational ball motion against seats<\/td>\n<\/tr>\n<tr data-start=\"12550\" data-end=\"12639\">\n<td data-start=\"12550\" data-end=\"12582\" data-col-size=\"sm\">Seat rubbing during operation<\/td>\n<td data-start=\"12582\" data-end=\"12604\" data-col-size=\"md\">Minimized by design<\/td>\n<td data-start=\"12604\" data-end=\"12639\" data-col-size=\"md\">Present during normal operation<\/td>\n<\/tr>\n<tr data-start=\"12640\" data-end=\"12748\">\n<td data-start=\"12640\" data-end=\"12661\" data-col-size=\"sm\">Seat wear tendency<\/td>\n<td data-start=\"12661\" data-end=\"12703\" data-col-size=\"md\">Lower in repeated severe isolation duty<\/td>\n<td data-start=\"12703\" data-end=\"12748\" data-col-size=\"md\">Higher in demanding or high-cycle service<\/td>\n<\/tr>\n<tr data-start=\"12749\" data-end=\"12859\">\n<td data-start=\"12749\" data-end=\"12774\" data-col-size=\"sm\">Torque trend over time<\/td>\n<td data-start=\"12774\" data-end=\"12815\" data-col-size=\"md\">More stable in suitable severe service<\/td>\n<td data-start=\"12815\" data-end=\"12859\" data-col-size=\"md\">May rise as seats wear or deposits build<\/td>\n<\/tr>\n<tr data-start=\"12860\" data-end=\"12944\">\n<td data-start=\"12860\" data-end=\"12876\" data-col-size=\"sm\">Shutoff focus<\/td>\n<td data-start=\"12876\" data-end=\"12909\" data-col-size=\"md\">Critical isolation reliability<\/td>\n<td data-start=\"12909\" data-end=\"12944\" data-col-size=\"md\">Broad general-purpose isolation<\/td>\n<\/tr>\n<tr data-start=\"12945\" data-end=\"13055\">\n<td data-start=\"12945\" data-end=\"12961\" data-col-size=\"sm\">Best use case<\/td>\n<td data-start=\"12961\" data-end=\"13015\" data-col-size=\"md\">Severe block duty, switching service, gas isolation<\/td>\n<td data-start=\"13015\" data-end=\"13055\" data-col-size=\"md\">General plant and pipeline isolation<\/td>\n<\/tr>\n<tr data-start=\"13056\" data-end=\"13097\">\n<td data-start=\"13056\" data-end=\"13071\" data-col-size=\"sm\">Initial cost<\/td>\n<td data-start=\"13071\" data-end=\"13080\" data-col-size=\"md\">Higher<\/td>\n<td data-start=\"13080\" data-end=\"13097\" data-col-size=\"md\">Usually lower<\/td>\n<\/tr>\n<tr data-start=\"13098\" data-end=\"13248\">\n<td data-start=\"13098\" data-end=\"13116\" data-col-size=\"sm\">Lifecycle logic<\/td>\n<td data-start=\"13116\" data-end=\"13174\" data-col-size=\"md\">Favored when maintenance and shutoff consistency matter<\/td>\n<td data-start=\"13174\" data-end=\"13248\" data-col-size=\"md\">Favored where service is less demanding and cost sensitivity is higher<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<figure id=\"attachment_8164\" aria-describedby=\"caption-attachment-8164\" style=\"width: 1536px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8164\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-vs-ball-valve-comparison-diagram.png\" alt=\"Orbit valve vs ball valve comparison diagram showing lift then turn mechanism versus rotating ball sealing\" width=\"1536\" height=\"1024\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-vs-ball-valve-comparison-diagram.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-vs-ball-valve-comparison-diagram-768x512.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-vs-ball-valve-comparison-diagram-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-vs-ball-valve-comparison-diagram-600x400.png 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><figcaption id=\"caption-attachment-8164\" class=\"wp-caption-text\">Comparison between orbit valve and conventional ball valve sealing mechanisms.<\/figcaption><\/figure>\n<h3 data-section-id=\"1xm4b3h\" data-start=\"13250\" data-end=\"13319\"><span class=\"ez-toc-section\" id=\"Quick_Selection_Guide_%E2%80%94_When_Is_an_Orbit_Valve_Worth_the_Premium\"><\/span>Quick Selection Guide \u2014 When Is an Orbit Valve Worth the Premium?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"13321\" data-end=\"13390\">Choose an orbit valve for evaluation first when the service involves:<\/p>\n<ul data-start=\"13392\" data-end=\"13677\">\n<li data-section-id=\"1jv3s5\" data-start=\"13392\" data-end=\"13426\">\n<p data-start=\"13394\" data-end=\"13426\"><strong data-start=\"13394\" data-end=\"13426\">high-cycle dry gas isolation<\/strong><\/p>\n<\/li>\n<li data-section-id=\"olddpo\" data-start=\"13427\" data-end=\"13464\">\n<p data-start=\"13429\" data-end=\"13464\"><strong data-start=\"13429\" data-end=\"13464\">molecular sieve dryer switching<\/strong><\/p>\n<\/li>\n<li data-section-id=\"1bkhq20\" data-start=\"13465\" data-end=\"13524\">\n<p data-start=\"13467\" data-end=\"13524\"><strong data-start=\"13467\" data-end=\"13524\">critical block duty where shutoff consistency matters<\/strong><\/p>\n<\/li>\n<li data-section-id=\"1c7doxh\" data-start=\"13525\" data-end=\"13596\">\n<p data-start=\"13527\" data-end=\"13596\"><strong data-start=\"13527\" data-end=\"13596\">applications where seat wear has already been a recurring problem<\/strong><\/p>\n<\/li>\n<li data-section-id=\"1289kvo\" data-start=\"13597\" data-end=\"13677\">\n<p data-start=\"13599\" data-end=\"13677\"><strong data-start=\"13599\" data-end=\"13677\">shutdown or switching duty where maintenance access is difficult or costly<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"13679\" data-end=\"13752\">A conventional <a href=\"https:\/\/ntgdvalve.com\/ball-valve\/\">ball valve<\/a> may still be the better commercial choice when:<\/p>\n<ul data-start=\"13754\" data-end=\"13980\">\n<li data-section-id=\"858aqf\" data-start=\"13754\" data-end=\"13800\">\n<p data-start=\"13756\" data-end=\"13800\">the service is <strong data-start=\"13771\" data-end=\"13800\">general-purpose isolation<\/strong><\/p>\n<\/li>\n<li data-section-id=\"1xtlbci\" data-start=\"13801\" data-end=\"13825\">\n<p data-start=\"13803\" data-end=\"13825\">cycle frequency is low<\/p>\n<\/li>\n<li data-section-id=\"1bz0ey4\" data-start=\"13826\" data-end=\"13877\">\n<p data-start=\"13828\" data-end=\"13877\">shutoff is important, but not unusually demanding<\/p>\n<\/li>\n<li data-section-id=\"x7vhzk\" data-start=\"13878\" data-end=\"13980\">\n<p data-start=\"13880\" data-end=\"13980\">the project is highly cost-sensitive and the operating conditions do not justify the orbit mechanism<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"13982\" data-end=\"14041\">This is not just a price comparison. It is a comparison of:<\/p>\n<ul data-start=\"14043\" data-end=\"14160\">\n<li data-section-id=\"11ggxkd\" data-start=\"14043\" data-end=\"14054\">\n<p data-start=\"14045\" data-end=\"14054\">seat life<\/p>\n<\/li>\n<li data-section-id=\"1tair2i\" data-start=\"14055\" data-end=\"14077\">\n<p data-start=\"14057\" data-end=\"14077\">maintenance interval<\/p>\n<\/li>\n<li data-section-id=\"4htd6b\" data-start=\"14078\" data-end=\"14099\">\n<p data-start=\"14080\" data-end=\"14099\">shutoff consistency<\/p>\n<\/li>\n<li data-section-id=\"1wkutj0\" data-start=\"14100\" data-end=\"14119\">\n<p data-start=\"14102\" data-end=\"14119\">downtime exposure<\/p>\n<\/li>\n<li data-section-id=\"1lqr1sl\" data-start=\"14120\" data-end=\"14160\">\n<p data-start=\"14122\" data-end=\"14160\">documentation and project expectations between orbit valves and <a href=\"https:\/\/ntgdvalve.com\/floating-ball-valve-2\/\">floating ball valves<\/a> and <a href=\"https:\/\/ntgdvalve.com\/trunnion-ball-valve\/\">trunnion ball valves<\/a><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"14295\" data-end=\"14298\" \/>\n<h2 data-section-id=\"10en824\" data-start=\"14300\" data-end=\"14328\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_vs_Plug_Valve\"><\/span>Orbit Valve vs Plug Valve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"14330\" data-end=\"14440\">Orbit valves and plug valves are both used in shutoff service, but they are not selected for the same reasons.<\/p>\n<p data-start=\"14442\" data-end=\"14678\">A <a href=\"https:\/\/ntgdvalve.com\/plug-valve\/\">plug valve<\/a> is often considered where cavity behavior, solids handling, or particular shutoff geometry suits the application. An orbit valve is more specifically selected for <strong data-start=\"14618\" data-end=\"14677\">critical isolation using a non-rubbing shutoff sequence<\/strong>.<\/p>\n<p data-start=\"14680\" data-end=\"14708\">The right choice depends on:<\/p>\n<ul data-start=\"14710\" data-end=\"14808\">\n<li data-section-id=\"2331fs\" data-start=\"14710\" data-end=\"14726\">\n<p data-start=\"14712\" data-end=\"14726\">service medium<\/p>\n<\/li>\n<li data-section-id=\"5vzcf\" data-start=\"14727\" data-end=\"14743\">\n<p data-start=\"14729\" data-end=\"14743\">solids content<\/p>\n<\/li>\n<li data-section-id=\"1811h0c\" data-start=\"14744\" data-end=\"14761\">\n<p data-start=\"14746\" data-end=\"14761\">cycle frequency<\/p>\n<\/li>\n<li data-section-id=\"10elfxb\" data-start=\"14762\" data-end=\"14783\">\n<p data-start=\"14764\" data-end=\"14783\">shutoff expectation<\/p>\n<\/li>\n<li data-section-id=\"1ypdq0q\" data-start=\"14784\" data-end=\"14808\">\n<p data-start=\"14786\" data-end=\"14808\">maintenance philosophy \uff08which is why some engineers still evaluate <a href=\"https:\/\/ntgdvalve.com\/lubricated-plug-valve\/\">lubricated plug valves<\/a> for cavity-sensitive service\uff09<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"14918\" data-end=\"14921\" \/>\n<h2 data-section-id=\"11ste6t\" data-start=\"14923\" data-end=\"14951\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_vs_Gate_Valve\"><\/span>Orbit Valve vs Gate Valve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"14953\" data-end=\"15143\">A <a href=\"https:\/\/ntgdvalve.com\/gate-valve\/\">gate valve<\/a> uses a linear gate movement and is widely used in general shutoff service. An orbit valve uses a guided lift-and-turn motion that separates the sealing surfaces before rotation.<\/p>\n<p data-start=\"15145\" data-end=\"15362\">In repeated severe isolation service, an orbit valve may offer a more suitable shutoff mechanism. In lower-cycle general isolation service, a conventional gate valve may remain the more familiar and economical choice.<\/p>\n<hr data-start=\"15364\" data-end=\"15367\" \/>\n<h2 data-section-id=\"7houww\" data-start=\"15369\" data-end=\"15407\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Applications_by_Service\"><\/span>Orbit Valve Applications by Service<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"attachment_8163\" aria-describedby=\"caption-attachment-8163\" style=\"width: 1536px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8163\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-typical-applications-diagram.png\" alt=\"Orbit valve applications in gas transmission pipelines molecular sieve dryers and emergency shutdown systems\" width=\"1536\" height=\"1024\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-typical-applications-diagram.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-typical-applications-diagram-768x512.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-typical-applications-diagram-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-typical-applications-diagram-600x400.png 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><figcaption id=\"caption-attachment-8163\" class=\"wp-caption-text\">Typical industrial applications where orbit valves are used for reliable shutoff.<\/figcaption><\/figure>\n<p data-start=\"15409\" data-end=\"15565\">The most useful way to describe orbit valve applications is not by listing industries, but by identifying <strong data-start=\"15515\" data-end=\"15564\">what problem the valve solves in each service<\/strong>.<\/p>\n<h3 data-section-id=\"121zlfg\" data-start=\"15567\" data-end=\"15611\"><span class=\"ez-toc-section\" id=\"Gas_Transmission_and_Compressor_Stations\"><\/span>Gas Transmission and Compressor Stations<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"15613\" data-end=\"15897\">Orbit valves are well suited for gas isolation systems where shutoff reliability, stable torque behavior, and maintenance predictability are important. In these services, repeated operation and sealing degradation can become lifecycle problems with conventional rotary shutoff valves.<\/p>\n<h3 data-section-id=\"1phze6a\" data-start=\"15899\" data-end=\"15934\"><span class=\"ez-toc-section\" id=\"Molecular_Sieve_Dryer_Switching\"><\/span>Molecular Sieve Dryer Switching<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"15936\" data-end=\"16247\">This is one of the most recognized orbit valve applications. Dryer switching duty often involves <strong data-start=\"16033\" data-end=\"16118\">frequent cycling, tight shutoff requirements, and strong reliability expectations<\/strong>. In such service, seat wear from repeated rubbing can become a serious issue. The orbit valve mechanism addresses that directly.<\/p>\n<h3 data-section-id=\"1u491m1\" data-start=\"16249\" data-end=\"16268\"><span class=\"ez-toc-section\" id=\"Meter_Isolation\"><\/span>Meter Isolation<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"16270\" data-end=\"16552\">Meter systems require dependable shutoff during maintenance, testing, or isolation procedures. In this context, the value of an orbit valve lies in its ability to provide <strong data-start=\"16441\" data-end=\"16474\">repeatable shutoff confidence<\/strong>, especially where sealing consistency matters more than commodity valve cost.<\/p>\n<h3 data-section-id=\"vpgd28\" data-start=\"16554\" data-end=\"16609\"><span class=\"ez-toc-section\" id=\"Emergency_Shutdown_ESD_and_Critical_Block_Service\"><\/span>Emergency Shutdown (ESD) and Critical Block Service<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"16611\" data-end=\"16888\">In shutdown service, the question is not just whether the valve can operate, but whether it can do so <strong data-start=\"16713\" data-end=\"16739\">reliably when required<\/strong>. Orbit valves are considered where actuator compatibility, severe-duty shutoff logic, and project documentation all matter in the selection process.<\/p>\n<h3 data-section-id=\"18x65la\" data-start=\"16890\" data-end=\"16931\"><span class=\"ez-toc-section\" id=\"Product_Segregation_and_Block_Service\"><\/span>Product Segregation and Block Service<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"16933\" data-end=\"17092\">Where fluid separation and positive shutoff are important, orbit valves may be chosen to reduce long-term sealing degradation and improve isolation confidence.<\/p>\n<h3 data-section-id=\"lz807f\" data-start=\"17094\" data-end=\"17153\"><span class=\"ez-toc-section\" id=\"Severe_Isolation_in_Oil_Gas_and_Petrochemical_Systems\"><\/span>Severe Isolation in Oil &amp; Gas and Petrochemical Systems<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"17155\" data-end=\"17227\">Orbit rising stem ball valves are often reviewed for projects involving:<\/p>\n<ul data-start=\"17229\" data-end=\"17413\">\n<li data-section-id=\"tksiyt\" data-start=\"17229\" data-end=\"17265\">\n<p data-start=\"17231\" data-end=\"17265\">upstream and midstream gas systems<\/p>\n<\/li>\n<li data-section-id=\"12d4kud\" data-start=\"17266\" data-end=\"17292\">\n<p data-start=\"17268\" data-end=\"17292\">petrochemical block duty<\/p>\n<\/li>\n<li data-section-id=\"dneo3m\" data-start=\"17293\" data-end=\"17310\">\n<p data-start=\"17295\" data-end=\"17310\">dryer switching<\/p>\n<\/li>\n<li data-section-id=\"1tl4am9\" data-start=\"17311\" data-end=\"17336\">\n<p data-start=\"17313\" data-end=\"17336\">severe isolation points<\/p>\n<\/li>\n<li data-section-id=\"1abagwh\" data-start=\"17337\" data-end=\"17413\">\n<p data-start=\"17339\" data-end=\"17413\">projects with specific emissions, fire-safe, or documentation requirements<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"17415\" data-end=\"17418\" \/>\n<h2 data-section-id=\"y4ms2r\" data-start=\"17420\" data-end=\"17451\"><span class=\"ez-toc-section\" id=\"How_to_Select_an_Orbit_Valve\"><\/span>How to Select an Orbit Valve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"17453\" data-end=\"17656\">Selecting an orbit valve correctly requires more than matching size and pressure class. The best results come from confirming both <strong data-start=\"17584\" data-end=\"17606\">service conditions<\/strong> and <strong data-start=\"17611\" data-end=\"17644\">project approval requirements<\/strong> before RFQ.<\/p>\n<h3 data-section-id=\"1sr6iia\" data-start=\"17658\" data-end=\"17691\"><span class=\"ez-toc-section\" id=\"1_Confirm_the_Service_Medium\"><\/span>1. Confirm the Service Medium<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"17693\" data-end=\"17721\">Start with the fluid itself:<\/p>\n<ul data-start=\"17723\" data-end=\"17823\">\n<li data-section-id=\"1v88oj6\" data-start=\"17723\" data-end=\"17732\">\n<p data-start=\"17725\" data-end=\"17732\">dry gas<\/p>\n<\/li>\n<li data-section-id=\"likxbz\" data-start=\"17733\" data-end=\"17753\">\n<p data-start=\"17735\" data-end=\"17753\">hydrocarbon liquid<\/p>\n<\/li>\n<li data-section-id=\"bqvmy8\" data-start=\"17754\" data-end=\"17771\">\n<p data-start=\"17756\" data-end=\"17771\">corrosive fluid<\/p>\n<\/li>\n<li data-section-id=\"5pw3ir\" data-start=\"17772\" data-end=\"17793\">\n<p data-start=\"17774\" data-end=\"17793\">sour service medium<\/p>\n<\/li>\n<li data-section-id=\"khj366\" data-start=\"17794\" data-end=\"17823\">\n<p data-start=\"17796\" data-end=\"17823\">emissions-sensitive service<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"17825\" data-end=\"17902\">This directly affects body material, trim, packing, and testing requirements.<\/p>\n<h3 data-section-id=\"1mztqv7\" data-start=\"17904\" data-end=\"17933\"><span class=\"ez-toc-section\" id=\"2_Confirm_Pressure_Class\"><\/span>2. Confirm Pressure Class<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"17935\" data-end=\"18046\">Define the required rating clearly, such as Class 150, 300, 600, 900, 1500, or project-specific higher ratings.<\/p>\n<h3 data-section-id=\"1c40h08\" data-start=\"18048\" data-end=\"18084\"><span class=\"ez-toc-section\" id=\"3_Confirm_Operating_Temperature\"><\/span>3. Confirm Operating Temperature<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"18086\" data-end=\"18200\">Temperature affects body and trim selection, packing arrangement, and the suitability of optional design features.<\/p>\n<h3 data-section-id=\"1kd0h6z\" data-start=\"18202\" data-end=\"18233\"><span class=\"ez-toc-section\" id=\"4_Confirm_Bore_Requirement\"><\/span>4. Confirm Bore Requirement<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"18235\" data-end=\"18372\">Identify whether the application needs <strong data-start=\"18274\" data-end=\"18287\">full bore<\/strong> or <strong data-start=\"18291\" data-end=\"18307\">reduced bore<\/strong>, depending on flow, pigging, and system resistance expectations.<\/p>\n<h3 data-section-id=\"1p8rfg6\" data-start=\"18374\" data-end=\"18403\"><span class=\"ez-toc-section\" id=\"5_Confirm_End_Connection\"><\/span>5. Confirm End Connection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"18405\" data-end=\"18429\">Typical options include:<\/p>\n<ul data-start=\"18431\" data-end=\"18475\">\n<li data-section-id=\"yc2oa3\" data-start=\"18431\" data-end=\"18440\">\n<p data-start=\"18433\" data-end=\"18440\">flanged<\/p>\n<\/li>\n<li data-section-id=\"dsy43p\" data-start=\"18441\" data-end=\"18452\">\n<p data-start=\"18443\" data-end=\"18452\">butt weld<\/p>\n<\/li>\n<li data-section-id=\"1mx3a87\" data-start=\"18453\" data-end=\"18475\">\n<p data-start=\"18455\" data-end=\"18475\">RTJ, where specified<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"60v4b1\" data-start=\"18477\" data-end=\"18508\"><span class=\"ez-toc-section\" id=\"6_Confirm_Actuation_Method\"><\/span>6. Confirm Actuation Method<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"18510\" data-end=\"18587\">Select based on site philosophy, response requirement, and available utility:<\/p>\n<ul data-start=\"18589\" data-end=\"18632\">\n<li data-section-id=\"157o86q\" data-start=\"18589\" data-end=\"18597\">\n<p data-start=\"18591\" data-end=\"18597\">manual<\/p>\n<\/li>\n<li data-section-id=\"uuzlg\" data-start=\"18598\" data-end=\"18609\">\n<p data-start=\"18600\" data-end=\"18609\">pneumatic<\/p>\n<\/li>\n<li data-section-id=\"l16p8r\" data-start=\"18610\" data-end=\"18620\">\n<p data-start=\"18612\" data-end=\"18620\">electric<\/p>\n<\/li>\n<li data-section-id=\"1wlm22l\" data-start=\"18621\" data-end=\"18632\">\n<p data-start=\"18623\" data-end=\"18632\">hydraulic<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"slf730\" data-start=\"18634\" data-end=\"18672\"><span class=\"ez-toc-section\" id=\"7_Confirm_Compliance_Requirements\"><\/span>7. Confirm Compliance Requirements<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"18674\" data-end=\"18708\">State any project requirement for:<\/p>\n<ul data-start=\"18710\" data-end=\"18855\">\n<li data-section-id=\"9o7c9i\" data-start=\"18710\" data-end=\"18738\">\n<p data-start=\"18712\" data-end=\"18738\">API-based design standards<\/p>\n<\/li>\n<li data-section-id=\"15mjdr2\" data-start=\"18739\" data-end=\"18757\">\n<p data-start=\"18741\" data-end=\"18757\">fire-safe design<\/p>\n<\/li>\n<li data-section-id=\"jqho2o\" data-start=\"18758\" data-end=\"18784\">\n<p data-start=\"18760\" data-end=\"18784\">low-emission performance<\/p>\n<\/li>\n<li data-section-id=\"klm0qc\" data-start=\"18785\" data-end=\"18806\">\n<p data-start=\"18787\" data-end=\"18806\">sour service review<\/p>\n<\/li>\n<li data-section-id=\"oc283a\" data-start=\"18807\" data-end=\"18831\">\n<p data-start=\"18809\" data-end=\"18831\">third-party inspection<\/p>\n<\/li>\n<li data-section-id=\"1h5c65c\" data-start=\"18832\" data-end=\"18855\">\n<p data-start=\"18834\" data-end=\"18855\">material traceability<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"17sewlv\" data-start=\"18857\" data-end=\"18891\"><span class=\"ez-toc-section\" id=\"8_Confirm_Operation_Frequency\"><\/span>8. Confirm Operation Frequency<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"18893\" data-end=\"19087\">A valve used rarely in shutdown service is not selected the same way as one used frequently in switching duty. Operation frequency should influence both design review and lifecycle expectations.<\/p>\n<h3 data-section-id=\"ev3thu\" data-start=\"19089\" data-end=\"19129\"><span class=\"ez-toc-section\" id=\"9_Confirm_the_Documentation_Package\"><\/span>9. Confirm the Documentation Package<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"19131\" data-end=\"19361\">In international industrial projects, documentation delays are often a larger commercial problem than fabrication itself. Missing or incomplete documents can delay approval, site acceptance, commissioning, or even payment release.<\/p>\n<p data-start=\"19363\" data-end=\"19541\">A missing MTC can create material traceability problems. A missing GA drawing can delay piping verification. A missing IOM manual can slow commissioning and maintenance planning.<\/p>\n<p data-start=\"19543\" data-end=\"19644\">For that reason, document requirements should be confirmed <strong data-start=\"19602\" data-end=\"19616\">during RFQ<\/strong>, not after order placement.<\/p>\n<h3 data-section-id=\"1akv4ll\" data-start=\"19646\" data-end=\"19683\"><span class=\"ez-toc-section\" id=\"Purchaser_Documentation_Checklist\"><\/span>Purchaser Documentation Checklist<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"19685\" data-end=\"20529\" data-extentions-extra-tablecapture-id=\"234072\">\n<thead data-start=\"19685\" data-end=\"19736\">\n<tr data-start=\"19685\" data-end=\"19736\">\n<th class=\"\" data-start=\"19685\" data-end=\"19696\" data-col-size=\"sm\">Document<\/th>\n<th class=\"\" data-start=\"19696\" data-end=\"19717\" data-col-size=\"md\">Why Buyer Needs It<\/th>\n<th class=\"\" data-start=\"19717\" data-end=\"19736\" data-col-size=\"md\">When to Confirm<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"19751\" data-end=\"20529\">\n<tr data-start=\"19751\" data-end=\"19872\">\n<td data-start=\"19751\" data-end=\"19773\" data-col-size=\"sm\">Technical Datasheet<\/td>\n<td data-start=\"19773\" data-end=\"19839\" data-col-size=\"md\">Confirms the commercial and technical offer matches the service<\/td>\n<td data-start=\"19839\" data-end=\"19872\" data-col-size=\"md\">Before quotation finalization<\/td>\n<\/tr>\n<tr data-start=\"19873\" data-end=\"19970\">\n<td data-start=\"19873\" data-end=\"19886\" data-col-size=\"sm\">GA Drawing<\/td>\n<td data-start=\"19886\" data-end=\"19943\" data-col-size=\"md\">Verifies dimensions, actuator envelope, and piping fit<\/td>\n<td data-start=\"19943\" data-end=\"19970\" data-col-size=\"md\">During technical review<\/td>\n<\/tr>\n<tr data-start=\"19971\" data-end=\"20103\">\n<td data-start=\"19971\" data-end=\"20001\" data-col-size=\"sm\">MTC \/ Material Certificates<\/td>\n<td data-start=\"20001\" data-end=\"20058\" data-col-size=\"md\">Supports material traceability and inspection approval<\/td>\n<td data-start=\"20058\" data-end=\"20103\" data-col-size=\"md\">Before PO or final document list approval<\/td>\n<\/tr>\n<tr data-start=\"20104\" data-end=\"20216\">\n<td data-start=\"20104\" data-end=\"20136\" data-col-size=\"sm\">Hydro \/ Seat Leak Test Report<\/td>\n<td data-start=\"20136\" data-end=\"20186\" data-col-size=\"md\">Confirms testing scope and shutoff verification<\/td>\n<td data-start=\"20186\" data-end=\"20216\" data-col-size=\"md\">Before FAT \/ final release<\/td>\n<\/tr>\n<tr data-start=\"20217\" data-end=\"20310\">\n<td data-start=\"20217\" data-end=\"20230\" data-col-size=\"sm\">IOM Manual<\/td>\n<td data-start=\"20230\" data-end=\"20291\" data-col-size=\"md\">Supports installation, operation, and maintenance planning<\/td>\n<td data-start=\"20291\" data-end=\"20310\" data-col-size=\"md\">Before shipment<\/td>\n<\/tr>\n<tr data-start=\"20311\" data-end=\"20420\">\n<td data-start=\"20311\" data-end=\"20340\" data-col-size=\"sm\">Painting \/ Marking Details<\/td>\n<td data-start=\"20340\" data-end=\"20394\" data-col-size=\"md\">Important for project conformity and field handling<\/td>\n<td data-start=\"20394\" data-end=\"20420\" data-col-size=\"md\">During order execution<\/td>\n<\/tr>\n<tr data-start=\"20421\" data-end=\"20529\">\n<td data-start=\"20421\" data-end=\"20452\" data-col-size=\"sm\">Inspection Release Documents<\/td>\n<td data-start=\"20452\" data-end=\"20502\" data-col-size=\"md\">Needed for QA handover and project file closure<\/td>\n<td data-start=\"20502\" data-end=\"20529\" data-col-size=\"md\">Before shipment release<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"17tp7sd\" data-start=\"20531\" data-end=\"20560\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_RFQ_Checklist\"><\/span>Orbit Valve RFQ Checklist<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"20562\" data-end=\"21118\" data-extentions-extra-tablecapture-id=\"395074\">\n<thead data-start=\"20562\" data-end=\"20593\">\n<tr data-start=\"20562\" data-end=\"20593\">\n<th class=\"\" data-start=\"20562\" data-end=\"20569\" data-col-size=\"sm\">Item<\/th>\n<th class=\"\" data-start=\"20569\" data-end=\"20593\" data-col-size=\"md\">Buyer Should Confirm<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"20604\" data-end=\"21118\">\n<tr data-start=\"20604\" data-end=\"20664\">\n<td data-start=\"20604\" data-end=\"20621\" data-col-size=\"sm\">Service medium<\/td>\n<td data-start=\"20621\" data-end=\"20664\" data-col-size=\"md\">Gas, liquid, corrosive, sour, dry, etc.<\/td>\n<\/tr>\n<tr data-start=\"20665\" data-end=\"20701\">\n<td data-start=\"20665\" data-end=\"20682\" data-col-size=\"sm\">Pressure class<\/td>\n<td data-start=\"20682\" data-end=\"20701\" data-col-size=\"md\">Required rating<\/td>\n<\/tr>\n<tr data-start=\"20702\" data-end=\"20761\">\n<td data-start=\"20702\" data-end=\"20716\" data-col-size=\"sm\">Temperature<\/td>\n<td data-start=\"20716\" data-end=\"20761\" data-col-size=\"md\">Minimum and maximum operating temperature<\/td>\n<\/tr>\n<tr data-start=\"20762\" data-end=\"20787\">\n<td data-start=\"20762\" data-end=\"20775\" data-col-size=\"sm\">Valve size<\/td>\n<td data-start=\"20775\" data-end=\"20787\" data-col-size=\"md\">NPS \/ DN<\/td>\n<\/tr>\n<tr data-start=\"20788\" data-end=\"20829\">\n<td data-start=\"20788\" data-end=\"20800\" data-col-size=\"sm\">Bore type<\/td>\n<td data-start=\"20800\" data-end=\"20829\" data-col-size=\"md\">Full bore or reduced bore<\/td>\n<\/tr>\n<tr data-start=\"20830\" data-end=\"20874\">\n<td data-start=\"20830\" data-end=\"20847\" data-col-size=\"sm\">End connection<\/td>\n<td data-start=\"20847\" data-end=\"20874\" data-col-size=\"md\">Flanged, BW, RTJ, other<\/td>\n<\/tr>\n<tr data-start=\"20875\" data-end=\"20929\">\n<td data-start=\"20875\" data-end=\"20887\" data-col-size=\"sm\">Actuation<\/td>\n<td data-start=\"20887\" data-end=\"20929\" data-col-size=\"md\">Manual, pneumatic, electric, hydraulic<\/td>\n<\/tr>\n<tr data-start=\"20930\" data-end=\"21005\">\n<td data-start=\"20930\" data-end=\"20943\" data-col-size=\"sm\">Compliance<\/td>\n<td data-start=\"20943\" data-end=\"21005\" data-col-size=\"md\">Fire-safe, low-emission, material review, inspection scope<\/td>\n<\/tr>\n<tr data-start=\"21006\" data-end=\"21061\">\n<td data-start=\"21006\" data-end=\"21016\" data-col-size=\"sm\">Testing<\/td>\n<td data-start=\"21016\" data-end=\"21061\" data-col-size=\"md\">Hydro, gas, seat leak, witness inspection<\/td>\n<\/tr>\n<tr data-start=\"21062\" data-end=\"21118\">\n<td data-start=\"21062\" data-end=\"21074\" data-col-size=\"sm\">Documents<\/td>\n<td data-start=\"21074\" data-end=\"21118\" data-col-size=\"md\">Datasheet, drawing, certificates, manual<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"t7c4ij\" data-start=\"21120\" data-end=\"21151\"><span class=\"ez-toc-section\" id=\"Material_Selection_Guidance\"><\/span>Material Selection Guidance<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"21153\" data-end=\"21736\" data-extentions-extra-tablecapture-id=\"285015\">\n<thead data-start=\"21153\" data-end=\"21243\">\n<tr data-start=\"21153\" data-end=\"21243\">\n<th class=\"\" data-start=\"21153\" data-end=\"21173\" data-col-size=\"sm\">Service Condition<\/th>\n<th class=\"\" data-start=\"21173\" data-end=\"21198\" data-col-size=\"sm\">Typical Body Direction<\/th>\n<th class=\"\" data-start=\"21198\" data-end=\"21222\" data-col-size=\"sm\">Trim \/ Seat Direction<\/th>\n<th class=\"\" data-start=\"21222\" data-end=\"21243\" data-col-size=\"sm\">Packing Direction<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"21262\" data-end=\"21736\">\n<tr data-start=\"21262\" data-end=\"21375\">\n<td data-start=\"21262\" data-end=\"21292\" data-col-size=\"sm\">General hydrocarbon service<\/td>\n<td data-start=\"21292\" data-end=\"21314\" data-col-size=\"sm\">Carbon steel option<\/td>\n<td data-start=\"21314\" data-end=\"21347\" data-col-size=\"sm\">Shutoff-focused trim selection<\/td>\n<td data-start=\"21347\" data-end=\"21375\" data-col-size=\"sm\">Standard project packing<\/td>\n<\/tr>\n<tr data-start=\"21376\" data-end=\"21493\">\n<td data-start=\"21376\" data-end=\"21404\" data-col-size=\"sm\">Corrosive process service<\/td>\n<td data-start=\"21404\" data-end=\"21432\" data-col-size=\"sm\">Stainless or alloy option<\/td>\n<td data-start=\"21432\" data-end=\"21466\" data-col-size=\"sm\">Corrosion-resistant trim review<\/td>\n<td data-start=\"21466\" data-end=\"21493\" data-col-size=\"sm\">Upgraded packing review<\/td>\n<\/tr>\n<tr data-start=\"21494\" data-end=\"21615\">\n<td data-start=\"21494\" data-end=\"21509\" data-col-size=\"sm\">Sour service<\/td>\n<td data-start=\"21509\" data-end=\"21547\" data-col-size=\"sm\">Service-reviewed material selection<\/td>\n<td data-start=\"21547\" data-end=\"21580\" data-col-size=\"sm\">Sour-service-compatible review<\/td>\n<td data-start=\"21580\" data-end=\"21615\" data-col-size=\"sm\">Project-specific packing review<\/td>\n<\/tr>\n<tr data-start=\"21616\" data-end=\"21736\">\n<td data-start=\"21616\" data-end=\"21650\" data-col-size=\"sm\">Emissions-sensitive gas service<\/td>\n<td data-start=\"21650\" data-end=\"21675\" data-col-size=\"sm\">Project-specified body<\/td>\n<td data-start=\"21675\" data-end=\"21705\" data-col-size=\"sm\">Shutoff-focused trim review<\/td>\n<td data-start=\"21705\" data-end=\"21736\" data-col-size=\"sm\">Low-emission packing option<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"21885\" data-end=\"21888\" \/>\n<h2 data-section-id=\"11542q4\" data-start=\"21890\" data-end=\"21932\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Actuators_and_Configuration\"><\/span>Orbit Valve Actuators and Configuration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure id=\"attachment_8165\" aria-describedby=\"caption-attachment-8165\" style=\"width: 1536px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8165\" src=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-pneumatic-actuated-product-photo.png\" alt=\"Electric actuated orbit valve with gearbox actuator for automated pipeline control\" width=\"1536\" height=\"1024\" srcset=\"https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-pneumatic-actuated-product-photo.png 1536w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-pneumatic-actuated-product-photo-768x512.png 768w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-pneumatic-actuated-product-photo-18x12.png 18w, https:\/\/ntgdvalve.com\/wp-content\/uploads\/2024\/07\/orbit-valve-pneumatic-actuated-product-photo-600x400.png 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><figcaption id=\"caption-attachment-8165\" class=\"wp-caption-text\">Electric orbit valve actuator used for remote control and automated pipeline systems.<\/figcaption><\/figure>\n<p data-start=\"21934\" data-end=\"22082\">The correct actuator is determined not only by available utility, but also by <strong data-start=\"22012\" data-end=\"22081\">shutdown philosophy, torque requirement, and response expectation<\/strong>.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"22084\" data-end=\"22743\" data-extentions-extra-tablecapture-id=\"848758\">\n<thead data-start=\"22084\" data-end=\"22148\">\n<tr data-start=\"22084\" data-end=\"22148\">\n<th class=\"\" data-start=\"22084\" data-end=\"22101\" data-col-size=\"sm\">Actuation Type<\/th>\n<th class=\"\" data-start=\"22101\" data-end=\"22112\" data-col-size=\"md\">Best For<\/th>\n<th class=\"\" data-start=\"22112\" data-end=\"22129\" data-col-size=\"md\">Main Advantage<\/th>\n<th class=\"\" data-start=\"22129\" data-end=\"22148\" data-col-size=\"md\">Main Limitation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"22167\" data-end=\"22743\">\n<tr data-start=\"22167\" data-end=\"22303\">\n<td data-start=\"22167\" data-end=\"22176\" data-col-size=\"sm\">Manual<\/td>\n<td data-start=\"22176\" data-end=\"22224\" data-col-size=\"md\">Local operation, lower automation requirement<\/td>\n<td data-start=\"22224\" data-end=\"22257\" data-col-size=\"md\">Simpler and lower initial cost<\/td>\n<td data-start=\"22257\" data-end=\"22303\" data-col-size=\"md\">Not ideal for remote or automatic shutdown<\/td>\n<\/tr>\n<tr data-start=\"22304\" data-end=\"22451\">\n<td data-start=\"22304\" data-end=\"22316\" data-col-size=\"sm\">Pneumatic<\/td>\n<td data-start=\"22316\" data-end=\"22352\" data-col-size=\"md\">Fast-response automated isolation<\/td>\n<td data-start=\"22352\" data-end=\"22402\" data-col-size=\"md\">Strong fit for process automation and ESD logic<\/td>\n<td data-start=\"22402\" data-end=\"22451\" data-col-size=\"md\">Requires air supply and accessory integration<\/td>\n<\/tr>\n<tr data-start=\"22452\" data-end=\"22620\">\n<td data-start=\"22452\" data-end=\"22463\" data-col-size=\"sm\">Electric<\/td>\n<td data-start=\"22463\" data-end=\"22518\" data-col-size=\"md\">Remote operation where compressed air is unavailable<\/td>\n<td data-start=\"22518\" data-end=\"22569\" data-col-size=\"md\">Good for electrically integrated control systems<\/td>\n<td data-start=\"22569\" data-end=\"22620\" data-col-size=\"md\">May require more detailed shutdown logic review<\/td>\n<\/tr>\n<tr data-start=\"22621\" data-end=\"22743\">\n<td data-start=\"22621\" data-end=\"22633\" data-col-size=\"sm\">Hydraulic<\/td>\n<td data-start=\"22633\" data-end=\"22679\" data-col-size=\"md\">High-force or specialized actuation systems<\/td>\n<td data-start=\"22679\" data-end=\"22706\" data-col-size=\"md\">Strong output capability<\/td>\n<td data-start=\"22706\" data-end=\"22743\" data-col-size=\"md\">Requires hydraulic support system<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"u9kao5\" data-start=\"22745\" data-end=\"22778\"><span class=\"ez-toc-section\" id=\"Key_Actuator_Selection_Points\"><\/span>Key Actuator Selection Points<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"22780\" data-end=\"22856\">When reviewing <strong data-start=\"22795\" data-end=\"22819\">orbit valve actuator<\/strong> requirements, buyers should confirm:<\/p>\n<ul data-start=\"22858\" data-end=\"23009\">\n<li data-section-id=\"vn8hgp\" data-start=\"22858\" data-end=\"22875\">\n<p data-start=\"22860\" data-end=\"22875\">required torque<\/p>\n<\/li>\n<li data-section-id=\"1o68i28\" data-start=\"22876\" data-end=\"22895\">\n<p data-start=\"22878\" data-end=\"22895\">open \/ close time<\/p>\n<\/li>\n<li data-section-id=\"1ywkho3\" data-start=\"22896\" data-end=\"22911\">\n<p data-start=\"22898\" data-end=\"22911\">fail position<\/p>\n<\/li>\n<li data-section-id=\"15sjw6x\" data-start=\"22912\" data-end=\"22941\">\n<p data-start=\"22914\" data-end=\"22941\">manual override requirement<\/p>\n<\/li>\n<li data-section-id=\"cn53wq\" data-start=\"22942\" data-end=\"22961\">\n<p data-start=\"22944\" data-end=\"22961\">control interface<\/p>\n<\/li>\n<li data-section-id=\"1i4cjpu\" data-start=\"22962\" data-end=\"22981\">\n<p data-start=\"22964\" data-end=\"22981\">accessory package<\/p>\n<\/li>\n<li data-section-id=\"m2m7xt\" data-start=\"22982\" data-end=\"23009\">\n<p data-start=\"22984\" data-end=\"23009\">local vs remote operation<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"23011\" data-end=\"23272\">Users searching for orbit valve actuators are usually trying to determine whether the valve can be supplied in the exact configuration their project needs. That is why actuator discussion should be based on configuration logic, not generic actuator definitions.<\/p>\n<hr data-start=\"23411\" data-end=\"23414\" \/>\n<h2 data-section-id=\"1rwo7tr\" data-start=\"23416\" data-end=\"23462\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Packing_and_Low-Emission_Design\"><\/span>Orbit Valve Packing and Low-Emission Design<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"23464\" data-end=\"23645\">Packing is a major selection checkpoint, not a minor accessory. In gas service or emissions-sensitive applications, stem sealing performance can be as important as internal shutoff, which is why buyers often review leakage requirements against <a href=\"https:\/\/www.iso.org\/standard\/61441.html\" target=\"_blank\" rel=\"noopener\">ISO 15848-1<\/a>.<\/p>\n<h3 data-section-id=\"11iyjox\" data-start=\"23647\" data-end=\"23670\"><span class=\"ez-toc-section\" id=\"Why_Packing_Matters\"><\/span>Why Packing Matters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"23672\" data-end=\"23698\">Packing selection affects:<\/p>\n<ul data-start=\"23700\" data-end=\"23842\">\n<li data-section-id=\"okxtoy\" data-start=\"23700\" data-end=\"23726\">\n<p data-start=\"23702\" data-end=\"23726\">external leakage control<\/p>\n<\/li>\n<li data-section-id=\"15o21oq\" data-start=\"23727\" data-end=\"23750\">\n<p data-start=\"23729\" data-end=\"23750\">emissions performance<\/p>\n<\/li>\n<li data-section-id=\"1tair2i\" data-start=\"23751\" data-end=\"23773\">\n<p data-start=\"23753\" data-end=\"23773\">maintenance interval<\/p>\n<\/li>\n<li data-section-id=\"1g313e4\" data-start=\"23774\" data-end=\"23795\">\n<p data-start=\"23776\" data-end=\"23795\">service suitability<\/p>\n<\/li>\n<li data-section-id=\"15vfe6f\" data-start=\"23796\" data-end=\"23842\">\n<p data-start=\"23798\" data-end=\"23842\">project acceptance in regulated applications<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"qzb3aq\" data-start=\"23844\" data-end=\"23887\"><span class=\"ez-toc-section\" id=\"Standard_Packing_vs_Low-Emission_Option\"><\/span>Standard Packing vs Low-Emission Option<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"23889\" data-end=\"24405\" data-extentions-extra-tablecapture-id=\"983785\">\n<thead data-start=\"23889\" data-end=\"23965\">\n<tr data-start=\"23889\" data-end=\"23965\">\n<th class=\"\" data-start=\"23889\" data-end=\"23903\" data-col-size=\"md\">Requirement<\/th>\n<th class=\"\" data-start=\"23903\" data-end=\"23932\" data-col-size=\"md\">Standard Packing Direction<\/th>\n<th class=\"\" data-start=\"23932\" data-end=\"23965\" data-col-size=\"md\">Low-Emission Option Direction<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"23980\" data-end=\"24405\">\n<tr data-start=\"23980\" data-end=\"24064\">\n<td data-start=\"23980\" data-end=\"24006\" data-col-size=\"md\">General plant isolation<\/td>\n<td data-start=\"24006\" data-end=\"24023\" data-col-size=\"md\">Often suitable<\/td>\n<td data-start=\"24023\" data-end=\"24064\" data-col-size=\"md\">Usually not required unless specified<\/td>\n<\/tr>\n<tr data-start=\"24065\" data-end=\"24172\">\n<td data-start=\"24065\" data-end=\"24113\" data-col-size=\"md\">Gas service with tighter leakage expectations<\/td>\n<td data-start=\"24113\" data-end=\"24134\" data-col-size=\"md\">May require review<\/td>\n<td data-start=\"24134\" data-end=\"24172\" data-col-size=\"md\">Often reviewed as preferred option<\/td>\n<\/tr>\n<tr data-start=\"24173\" data-end=\"24275\">\n<td data-start=\"24173\" data-end=\"24203\" data-col-size=\"md\">Emissions-sensitive project<\/td>\n<td data-start=\"24203\" data-end=\"24241\" data-col-size=\"md\">Usually insufficient without review<\/td>\n<td data-start=\"24241\" data-end=\"24275\" data-col-size=\"md\">Should be specified during RFQ<\/td>\n<\/tr>\n<tr data-start=\"24276\" data-end=\"24405\">\n<td data-start=\"24276\" data-end=\"24310\" data-col-size=\"md\">Maintenance-sensitive operation<\/td>\n<td data-start=\"24310\" data-end=\"24355\" data-col-size=\"md\">Depends on service and packing arrangement<\/td>\n<td data-start=\"24355\" data-end=\"24405\" data-col-size=\"md\">May improve long-term leakage control strategy<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"1g8s6rn\" data-start=\"24407\" data-end=\"24446\"><span class=\"ez-toc-section\" id=\"What_Buyers_Should_State_in_the_RFQ\"><\/span>What Buyers Should State in the RFQ<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"24448\" data-end=\"24702\">If the project has external leakage limits, hazardous gas exposure, or low-emission compliance requirements, that must be stated in the RFQ. Otherwise, the quote may be based on a standard packing arrangement that does not match the approval expectation.<\/p>\n<p data-start=\"24704\" data-end=\"24745\">An orbit valve may also be reviewed with:<\/p>\n<ul data-start=\"24747\" data-end=\"24881\">\n<li data-section-id=\"wwls5l\" data-start=\"24747\" data-end=\"24780\">\n<p data-start=\"24749\" data-end=\"24780\">injectable packing arrangements<\/p>\n<\/li>\n<li data-section-id=\"kvboei\" data-start=\"24781\" data-end=\"24822\">\n<p data-start=\"24783\" data-end=\"24822\">project-specific packing configurations<\/p>\n<\/li>\n<li data-section-id=\"154o3yy\" data-start=\"24823\" data-end=\"24881\">\n<p data-start=\"24825\" data-end=\"24881\">documentation support for emissions-related requirements<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"25159\" data-end=\"25162\" \/>\n<h2 data-section-id=\"4oyom3\" data-start=\"25164\" data-end=\"25201\"><span class=\"ez-toc-section\" id=\"Typical_Orbit_Valve_Specifications\"><\/span>Typical Orbit Valve Specifications<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"25203\" data-end=\"25362\">Below is a typical specification snapshot for an orbit rising stem ball valve page. Final scope should always be confirmed against actual project requirements.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"25364\" data-end=\"25996\" data-extentions-extra-tablecapture-id=\"978533\">\n<thead data-start=\"25364\" data-end=\"25401\">\n<tr data-start=\"25364\" data-end=\"25401\">\n<th class=\"\" data-start=\"25364\" data-end=\"25376\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"\" data-start=\"25376\" data-end=\"25401\" data-col-size=\"md\">Typical Project Range<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"25412\" data-end=\"25996\">\n<tr data-start=\"25412\" data-end=\"25457\">\n<td data-start=\"25412\" data-end=\"25425\" data-col-size=\"sm\">Valve Type<\/td>\n<td data-start=\"25425\" data-end=\"25457\" data-col-size=\"md\">Orbit Rising Stem Ball Valve<\/td>\n<\/tr>\n<tr data-start=\"25458\" data-end=\"25492\">\n<td data-start=\"25458\" data-end=\"25471\" data-col-size=\"sm\">Size Range<\/td>\n<td data-start=\"25471\" data-end=\"25492\" data-col-size=\"md\">Project-dependent<\/td>\n<\/tr>\n<tr data-start=\"25493\" data-end=\"25559\">\n<td data-start=\"25493\" data-end=\"25510\" data-col-size=\"sm\">Pressure Class<\/td>\n<td data-start=\"25510\" data-end=\"25559\" data-col-size=\"md\">Class 150 and above, subject to configuration<\/td>\n<\/tr>\n<tr data-start=\"25560\" data-end=\"25596\">\n<td data-start=\"25560\" data-end=\"25567\" data-col-size=\"sm\">Bore<\/td>\n<td data-start=\"25567\" data-end=\"25596\" data-col-size=\"md\">Full bore or reduced bore<\/td>\n<\/tr>\n<tr data-start=\"25597\" data-end=\"25676\">\n<td data-start=\"25597\" data-end=\"25614\" data-col-size=\"sm\">Body Materials<\/td>\n<td data-start=\"25614\" data-end=\"25676\" data-col-size=\"md\">Carbon steel, stainless steel, project-based alloy options<\/td>\n<\/tr>\n<tr data-start=\"25677\" data-end=\"25733\">\n<td data-start=\"25677\" data-end=\"25695\" data-col-size=\"sm\">End Connections<\/td>\n<td data-start=\"25695\" data-end=\"25733\" data-col-size=\"md\">Flanged, BW, RTJ, project-specific<\/td>\n<\/tr>\n<tr data-start=\"25734\" data-end=\"25788\">\n<td data-start=\"25734\" data-end=\"25746\" data-col-size=\"sm\">Actuation<\/td>\n<td data-start=\"25746\" data-end=\"25788\" data-col-size=\"md\">Manual, pneumatic, electric, hydraulic<\/td>\n<\/tr>\n<tr data-start=\"25789\" data-end=\"25827\">\n<td data-start=\"25789\" data-end=\"25805\" data-col-size=\"sm\">Service Focus<\/td>\n<td data-start=\"25805\" data-end=\"25827\" data-col-size=\"md\">Critical isolation<\/td>\n<\/tr>\n<tr data-start=\"25828\" data-end=\"25913\">\n<td data-start=\"25828\" data-end=\"25844\" data-col-size=\"sm\">Documentation<\/td>\n<td data-start=\"25844\" data-end=\"25913\" data-col-size=\"md\">Datasheet, drawing, test record, manual, subject to project scope<\/td>\n<\/tr>\n<tr data-start=\"25914\" data-end=\"25996\">\n<td data-start=\"25914\" data-end=\"25934\" data-col-size=\"sm\">Optional Features<\/td>\n<td data-start=\"25934\" data-end=\"25996\" data-col-size=\"md\">Fire-safe review, low-emission review, sour service review<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h3 data-section-id=\"1781ph7\" data-start=\"25998\" data-end=\"26043\"><span class=\"ez-toc-section\" id=\"What_Buyers_Usually_Need_Beyond_the_Table\"><\/span>What Buyers Usually Need Beyond the Table<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"26045\" data-end=\"26141\">A specification table alone is rarely enough for final project approval. Buyers often also need:<\/p>\n<ul data-start=\"26143\" data-end=\"26264\">\n<li data-section-id=\"vcrpvs\" data-start=\"26143\" data-end=\"26157\">\n<p data-start=\"26145\" data-end=\"26157\">catalog page<\/p>\n<\/li>\n<li data-section-id=\"1g36150\" data-start=\"26158\" data-end=\"26179\">\n<p data-start=\"26160\" data-end=\"26179\">technical datasheet<\/p>\n<\/li>\n<li data-section-id=\"1v0fkby\" data-start=\"26180\" data-end=\"26192\">\n<p data-start=\"26182\" data-end=\"26192\">GA drawing<\/p>\n<\/li>\n<li data-section-id=\"1b6ve27\" data-start=\"26193\" data-end=\"26211\">\n<p data-start=\"26195\" data-end=\"26211\">material summary<\/p>\n<\/li>\n<li data-section-id=\"11eb9w\" data-start=\"26212\" data-end=\"26227\">\n<p data-start=\"26214\" data-end=\"26227\">testing scope<\/p>\n<\/li>\n<li data-section-id=\"1gvtycf\" data-start=\"26228\" data-end=\"26245\">\n<p data-start=\"26230\" data-end=\"26245\">marking details<\/p>\n<\/li>\n<li data-section-id=\"1jx7g5b\" data-start=\"26246\" data-end=\"26264\">\n<p data-start=\"26248\" data-end=\"26264\">certificate list<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"26266\" data-end=\"26269\" \/>\n<h2 data-section-id=\"1eb8tjw\" data-start=\"26271\" data-end=\"26305\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Diagrams_Drawings\"><\/span>Orbit Valve Diagrams &amp; Drawings<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"26307\" data-end=\"26477\">Buyers searching <strong data-start=\"26324\" data-end=\"26347\">orbit valve diagram<\/strong> or <strong data-start=\"26351\" data-end=\"26374\">orbit valve drawing<\/strong> often want immediate access to a visual technical reference rather than a general product explanation.<\/p>\n<p data-start=\"26479\" data-end=\"26543\">This page should include or link to the following diagram types:<\/p>\n<ul data-start=\"26545\" data-end=\"26706\">\n<li data-section-id=\"1tlt4ru\" data-start=\"26545\" data-end=\"26572\">\n<p data-start=\"26547\" data-end=\"26572\">Working Principle Diagram<\/p>\n<\/li>\n<li data-section-id=\"cqm8ub\" data-start=\"26573\" data-end=\"26602\">\n<p data-start=\"26575\" data-end=\"26602\">Parts Cross-Section Diagram<\/p>\n<\/li>\n<li data-section-id=\"18pm5th\" data-start=\"26603\" data-end=\"26627\">\n<p data-start=\"26605\" data-end=\"26627\">Packing Detail Diagram<\/p>\n<\/li>\n<li data-section-id=\"10lmnr4\" data-start=\"26628\" data-end=\"26657\">\n<p data-start=\"26630\" data-end=\"26657\">General Arrangement Drawing<\/p>\n<\/li>\n<li data-section-id=\"1mw4tq0\" data-start=\"26658\" data-end=\"26677\">\n<p data-start=\"26660\" data-end=\"26677\">Dimension Drawing<\/p>\n<\/li>\n<li data-section-id=\"2rn64p\" data-start=\"26678\" data-end=\"26706\">\n<p data-start=\"26680\" data-end=\"26706\">Parts Identification Sheet<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"26708\" data-end=\"26737\">Where possible, provide both:<\/p>\n<ul data-start=\"26739\" data-end=\"26778\">\n<li data-section-id=\"14cdi22\" data-start=\"26739\" data-end=\"26756\">\n<p data-start=\"26741\" data-end=\"26756\"><strong data-start=\"26741\" data-end=\"26756\">view online<\/strong><\/p>\n<\/li>\n<li data-section-id=\"6nmpi4\" data-start=\"26757\" data-end=\"26778\">\n<p data-start=\"26759\" data-end=\"26778\"><strong data-start=\"26759\" data-end=\"26778\">download as PDF<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"1qjmjkt\" data-start=\"26780\" data-end=\"26811\"><span class=\"ez-toc-section\" id=\"Recommended_Download_Blocks\"><\/span>Recommended Download Blocks<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul data-start=\"26813\" data-end=\"26983\">\n<li data-section-id=\"198dpc7\" data-start=\"26813\" data-end=\"26867\">\n<p data-start=\"26815\" data-end=\"26867\">Download Orbit Valve Working Principle Diagram (PDF)<\/p>\n<\/li>\n<li data-section-id=\"1aqx86s\" data-start=\"26868\" data-end=\"26910\">\n<p data-start=\"26870\" data-end=\"26910\">Download Orbit Valve Parts Diagram (PDF)<\/p>\n<\/li>\n<li data-section-id=\"oosz5h\" data-start=\"26911\" data-end=\"26943\">\n<p data-start=\"26913\" data-end=\"26943\">Request Orbit Valve GA Drawing<\/p>\n<\/li>\n<li data-section-id=\"9t2hb7\" data-start=\"26944\" data-end=\"26983\">\n<p data-start=\"26946\" data-end=\"26983\">Request Orbit Valve Dimension Drawing<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"26985\" data-end=\"27131\">This section is especially important because visual engineering assets often support both <strong data-start=\"27075\" data-end=\"27095\">technical review<\/strong> and <strong data-start=\"27100\" data-end=\"27130\">internal customer approval<\/strong>.<\/p>\n<hr data-start=\"27133\" data-end=\"27136\" \/>\n<h2 data-section-id=\"118nn6g\" data-start=\"27138\" data-end=\"27196\"><span class=\"ez-toc-section\" id=\"Orbit_Valve_Catalog_Datasheet_Drawing_O_M_Resources\"><\/span>Orbit Valve Catalog, Datasheet, Drawing &amp; O&amp;M Resources<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"27198\" data-end=\"27338\">High-intent buyers often search <strong data-start=\"27230\" data-end=\"27253\">orbit valve catalog<\/strong> because they need technical reference material before asking for a formal quotation.<\/p>\n<h3 data-section-id=\"1w9hl2o\" data-start=\"27340\" data-end=\"27370\"><span class=\"ez-toc-section\" id=\"Instant_Download_Resources\"><\/span>Instant Download Resources<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"27372\" data-end=\"27431\">Where available, this page should provide direct access to:<\/p>\n<ul data-start=\"27433\" data-end=\"27500\">\n<li data-section-id=\"szlt1s\" data-start=\"27433\" data-end=\"27450\">\n<p data-start=\"27435\" data-end=\"27450\">Product Catalog<\/p>\n<\/li>\n<li data-section-id=\"1fuqnma\" data-start=\"27451\" data-end=\"27480\">\n<p data-start=\"27453\" data-end=\"27480\">General Technical Datasheet<\/p>\n<\/li>\n<li data-section-id=\"9zgpuz\" data-start=\"27481\" data-end=\"27500\">\n<p data-start=\"27483\" data-end=\"27500\">Parts Diagram PDF<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"6nyhnr\" data-start=\"27502\" data-end=\"27537\"><span class=\"ez-toc-section\" id=\"Request-Based_Project_Resources\"><\/span>Request-Based Project Resources<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"27539\" data-end=\"27627\">The following are usually project-specific and should be requested with service details:<\/p>\n<ul data-start=\"27629\" data-end=\"27715\">\n<li data-section-id=\"1yzwuz2\" data-start=\"27629\" data-end=\"27641\">\n<p data-start=\"27631\" data-end=\"27641\">GA Drawing<\/p>\n<\/li>\n<li data-section-id=\"vfklg6\" data-start=\"27642\" data-end=\"27654\">\n<p data-start=\"27644\" data-end=\"27654\">O&amp;M Manual<\/p>\n<\/li>\n<li data-section-id=\"1komy5r\" data-start=\"27655\" data-end=\"27673\">\n<p data-start=\"27657\" data-end=\"27673\">Material Summary<\/p>\n<\/li>\n<li data-section-id=\"ho3z53\" data-start=\"27674\" data-end=\"27715\">\n<p data-start=\"27676\" data-end=\"27715\">Inspection \/ Test Documentation Package<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"zhfynn\" data-start=\"27717\" data-end=\"27754\"><span class=\"ez-toc-section\" id=\"Recommended_Resource_Access_Logic\"><\/span>Recommended Resource Access Logic<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul data-start=\"27756\" data-end=\"27952\">\n<li data-section-id=\"1n004qu\" data-start=\"27756\" data-end=\"27803\">\n<p data-start=\"27758\" data-end=\"27803\">use <strong data-start=\"27762\" data-end=\"27781\">direct download<\/strong> for general resources<\/p>\n<\/li>\n<li data-section-id=\"vlkj0l\" data-start=\"27804\" data-end=\"27867\">\n<p data-start=\"27806\" data-end=\"27867\">use <strong data-start=\"27810\" data-end=\"27836\">request-based delivery<\/strong> for project-specific documents<\/p>\n<\/li>\n<li data-section-id=\"masblu\" data-start=\"27868\" data-end=\"27952\">\n<p data-start=\"27870\" data-end=\"27952\">clearly distinguish between general and project-specific files to reduce confusion<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"27954\" data-end=\"27975\"><strong data-start=\"27954\" data-end=\"27975\">Recommended CTAs:<\/strong><\/p>\n<ul data-start=\"27976\" data-end=\"28125\">\n<li data-section-id=\"10t9452\" data-start=\"27976\" data-end=\"28012\">\n<p data-start=\"27978\" data-end=\"28012\">Download Orbit Valve Catalog (PDF)<\/p>\n<\/li>\n<li data-section-id=\"1qce7t2\" data-start=\"28013\" data-end=\"28051\">\n<p data-start=\"28015\" data-end=\"28051\">Download General Technical Datasheet<\/p>\n<\/li>\n<li data-section-id=\"u5cinz\" data-start=\"28052\" data-end=\"28072\">\n<p data-start=\"28054\" data-end=\"28072\">Request GA Drawing<\/p>\n<\/li>\n<li data-section-id=\"1h4vj1j\" data-start=\"28073\" data-end=\"28093\">\n<p data-start=\"28075\" data-end=\"28093\">Request O&amp;M Manual<\/p>\n<\/li>\n<li data-section-id=\"1vv8ktt\" data-start=\"28094\" data-end=\"28125\">\n<p data-start=\"28096\" data-end=\"28125\">Request Documentation Package<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"28255\" data-end=\"28258\" \/>\n<h2 data-section-id=\"1c800fk\" data-start=\"28260\" data-end=\"28303\"><span class=\"ez-toc-section\" id=\"Why_Choose_NTGD_for_Orbit_Valve_Projects\"><\/span>Why Choose NTGD for Orbit Valve Projects<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"28305\" data-end=\"28550\">Buyers searching for <strong data-start=\"28326\" data-end=\"28354\">orbit valve manufacturer<\/strong>, <strong data-start=\"28356\" data-end=\"28380\">orbit valve supplier<\/strong>, or <strong data-start=\"28385\" data-end=\"28408\">orbit valve company<\/strong> are not just looking for definitions. They are evaluating whether the supplier can support a real project from RFQ to documentation handover.<\/p>\n<h3 data-section-id=\"d9bf7y\" data-start=\"28552\" data-end=\"28596\"><span class=\"ez-toc-section\" id=\"What_NTGD_Supports_in_an_Orbit_Valve_RFQ\"><\/span>What NTGD Supports in an Orbit Valve RFQ<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"28598\" data-end=\"28642\">NTGD can support orbit valve inquiries with:<\/p>\n<ul data-start=\"28644\" data-end=\"28869\">\n<li data-section-id=\"1oewf4k\" data-start=\"28644\" data-end=\"28680\">\n<p data-start=\"28646\" data-end=\"28680\">application-based selection review<\/p>\n<\/li>\n<li data-section-id=\"13mxvmu\" data-start=\"28681\" data-end=\"28717\">\n<p data-start=\"28683\" data-end=\"28717\">actuation configuration discussion<\/p>\n<\/li>\n<li data-section-id=\"pmc8ig\" data-start=\"28718\" data-end=\"28737\">\n<p data-start=\"28720\" data-end=\"28737\">datasheet support<\/p>\n<\/li>\n<li data-section-id=\"1wshno0\" data-start=\"28738\" data-end=\"28767\">\n<p data-start=\"28740\" data-end=\"28767\">GA drawing request handling<\/p>\n<\/li>\n<li data-section-id=\"1w6ljz1\" data-start=\"28768\" data-end=\"28797\">\n<p data-start=\"28770\" data-end=\"28797\">document package discussion<\/p>\n<\/li>\n<li data-section-id=\"1amt8bx\" data-start=\"28798\" data-end=\"28826\">\n<p data-start=\"28800\" data-end=\"28826\">replacement inquiry review<\/p>\n<\/li>\n<li data-section-id=\"1mkn519\" data-start=\"28827\" data-end=\"28869\">\n<p data-start=\"28829\" data-end=\"28869\">technical clarification during RFQ stage<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"1fayov7\" data-start=\"28871\" data-end=\"28918\"><span class=\"ez-toc-section\" id=\"What_Buyers_Usually_Care_About_Beyond_Price\"><\/span>What Buyers Usually Care About Beyond Price<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"28920\" data-end=\"28985\">In project procurement, buyers often evaluate suppliers based on:<\/p>\n<ul data-start=\"28987\" data-end=\"29185\">\n<li data-section-id=\"1af6dnw\" data-start=\"28987\" data-end=\"29003\">\n<p data-start=\"28989\" data-end=\"29003\">response speed<\/p>\n<\/li>\n<li data-section-id=\"1xrd1lv\" data-start=\"29004\" data-end=\"29023\">\n<p data-start=\"29006\" data-end=\"29023\">technical clarity<\/p>\n<\/li>\n<li data-section-id=\"1xo6r9\" data-start=\"29024\" data-end=\"29047\">\n<p data-start=\"29026\" data-end=\"29047\">documentation support<\/p>\n<\/li>\n<li data-section-id=\"13wf77e\" data-start=\"29048\" data-end=\"29084\">\n<p data-start=\"29050\" data-end=\"29084\">conformity to project requirements<\/p>\n<\/li>\n<li data-section-id=\"gahr57\" data-start=\"29085\" data-end=\"29123\">\n<p data-start=\"29087\" data-end=\"29123\">testing and inspection communication<\/p>\n<\/li>\n<li data-section-id=\"18ifp56\" data-start=\"29124\" data-end=\"29185\">\n<p data-start=\"29126\" data-end=\"29185\">ability to support replacements or changes during execution<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"29187\" data-end=\"29325\">That is why orbit valve supply should be presented not only as a hardware offer, but as a <strong data-start=\"29277\" data-end=\"29324\">technical and documentation support process<\/strong>.<\/p>\n<h3 data-section-id=\"1rd334f\" data-start=\"29327\" data-end=\"29364\"><span class=\"ez-toc-section\" id=\"Global_Supply_and_Project_Support\"><\/span>Global Supply and Project Support<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"29366\" data-end=\"29414\">Depending on project scope, support may include:<\/p>\n<ul data-start=\"29416\" data-end=\"29590\">\n<li data-section-id=\"10o8of2\" data-start=\"29416\" data-end=\"29453\">\n<p data-start=\"29418\" data-end=\"29453\">severe isolation application review<\/p>\n<\/li>\n<li data-section-id=\"170jz9a\" data-start=\"29454\" data-end=\"29484\">\n<p data-start=\"29456\" data-end=\"29484\">gas service isolation review<\/p>\n<\/li>\n<li data-section-id=\"1xlt2tj\" data-start=\"29485\" data-end=\"29525\">\n<p data-start=\"29487\" data-end=\"29525\">actuation-related technical discussion<\/p>\n<\/li>\n<li data-section-id=\"194qp4s\" data-start=\"29526\" data-end=\"29557\">\n<p data-start=\"29528\" data-end=\"29557\">drawing and data confirmation<\/p>\n<\/li>\n<li data-section-id=\"1p7f84x\" data-start=\"29558\" data-end=\"29590\">\n<p data-start=\"29560\" data-end=\"29590\">replacement inquiry assistance<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"29592\" data-end=\"29739\">Have a current orbit valve RFQ or replacement need? Share your datasheet, nameplate, or project conditions with our engineering team.<\/p>\n<hr data-start=\"29741\" data-end=\"29744\" \/>\n<h2 data-section-id=\"15yst69\" data-start=\"29746\" data-end=\"29786\"><span class=\"ez-toc-section\" id=\"Replacement_and_Compatibility_Support\"><\/span>Replacement and Compatibility Support<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"29788\" data-end=\"29979\">Many replacement inquiries are not for new design projects, but for installed valves already in service. In those cases, the most useful first step is a <strong data-start=\"29941\" data-end=\"29978\">case-by-case compatibility review<\/strong>.<\/p>\n<p data-start=\"29981\" data-end=\"30058\">NTGD can review replacement inquiries based on available information such as:<\/p>\n<ul data-start=\"30060\" data-end=\"30224\">\n<li data-section-id=\"kqia7w\" data-start=\"30060\" data-end=\"30081\">\n<p data-start=\"30062\" data-end=\"30081\">original valve size<\/p>\n<\/li>\n<li data-section-id=\"ch03cz\" data-start=\"30082\" data-end=\"30098\">\n<p data-start=\"30084\" data-end=\"30098\">pressure class<\/p>\n<\/li>\n<li data-section-id=\"14p8eoj\" data-start=\"30099\" data-end=\"30114\">\n<p data-start=\"30101\" data-end=\"30114\">body material<\/p>\n<\/li>\n<li data-section-id=\"1fmj3n5\" data-start=\"30115\" data-end=\"30131\">\n<p data-start=\"30117\" data-end=\"30131\">end connection<\/p>\n<\/li>\n<li data-section-id=\"1xqtmku\" data-start=\"30132\" data-end=\"30148\">\n<p data-start=\"30134\" data-end=\"30148\">actuation type<\/p>\n<\/li>\n<li data-section-id=\"1im8rwz\" data-start=\"30149\" data-end=\"30165\">\n<p data-start=\"30151\" data-end=\"30165\">nameplate data<\/p>\n<\/li>\n<li data-section-id=\"1y7qym7\" data-start=\"30166\" data-end=\"30190\">\n<p data-start=\"30168\" data-end=\"30190\">installed valve photos<\/p>\n<\/li>\n<li data-section-id=\"4qfhp5\" data-start=\"30191\" data-end=\"30224\">\n<p data-start=\"30193\" data-end=\"30224\">existing drawings or datasheets<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"30226\" data-end=\"30446\">Some buyers contact us when evaluating replacement options for installed orbit valves from other major brands. Compatibility should be reviewed based on actual installed valve data rather than assumed interchangeability.<\/p>\n<h3 data-section-id=\"k7l7sc\" data-start=\"30448\" data-end=\"30491\"><span class=\"ez-toc-section\" id=\"Best_Way_to_Start_a_Replacement_Inquiry\"><\/span>Best Way to Start a Replacement Inquiry<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"30493\" data-end=\"30520\">For faster review, provide:<\/p>\n<ul data-start=\"30522\" data-end=\"30680\">\n<li data-section-id=\"i1w2av\" data-start=\"30522\" data-end=\"30545\">\n<p data-start=\"30524\" data-end=\"30545\">valve nameplate photo<\/p>\n<\/li>\n<li data-section-id=\"1ddu3wa\" data-start=\"30546\" data-end=\"30583\">\n<p data-start=\"30548\" data-end=\"30583\">project specification, if available<\/p>\n<\/li>\n<li data-section-id=\"180kyep\" data-start=\"30584\" data-end=\"30602\">\n<p data-start=\"30586\" data-end=\"30602\">valve tag number<\/p>\n<\/li>\n<li data-section-id=\"fo4dr6\" data-start=\"30603\" data-end=\"30639\">\n<p data-start=\"30605\" data-end=\"30639\">known leakage or maintenance issue<\/p>\n<\/li>\n<li data-section-id=\"1xq4egn\" data-start=\"30640\" data-end=\"30680\">\n<p data-start=\"30642\" data-end=\"30680\">drawing or old datasheet, if available<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"30731\" data-end=\"30734\" \/>\n<h2 data-section-id=\"1g291xn\" data-start=\"30736\" data-end=\"30784\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions_About_Orbit_Valves\"><\/span>Frequently Asked Questions About Orbit Valves<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 data-section-id=\"1qukv70\" data-start=\"30786\" data-end=\"30813\"><span class=\"ez-toc-section\" id=\"What_is_an_orbit_valve\"><\/span>What is an orbit valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"30815\" data-end=\"31182\">An orbit valve is a severe-service isolation valve that uses a rising stem lift-and-turn mechanism to open and close without the sealing surfaces rubbing during rotation. It is typically selected where shutoff reliability and lower seat wear matter in repeated service.<br data-start=\"31084\" data-end=\"31087\" \/><strong data-start=\"31087\" data-end=\"31107\">Internal prompt:<\/strong> See the working principle section above for the 4-step operating sequence.<\/p>\n<h3 data-section-id=\"1ekxwtq\" data-start=\"31184\" data-end=\"31242\"><span class=\"ez-toc-section\" id=\"Why_is_an_orbit_valve_called_a_rising_stem_ball_valve\"><\/span>Why is an orbit valve called a rising stem ball valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"31244\" data-end=\"31559\">It is called a rising stem ball valve because the closure element lifts away from the seat before rotating. That rising motion separates the sealing surfaces first, helping reduce abrasion compared with a conventional ball valve.<br data-start=\"31473\" data-end=\"31476\" \/><strong data-start=\"31476\" data-end=\"31496\">Internal prompt:<\/strong> See the working principle and comparison sections for details.<\/p>\n<h3 data-section-id=\"b8eo89\" data-start=\"31561\" data-end=\"31628\"><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_an_orbit_valve_and_a_ball_valve\"><\/span>What is the difference between an orbit valve and a ball valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"31630\" data-end=\"31968\">A conventional ball valve rotates against the seats during operation, while an orbit valve lifts the core away from the seat before rotation. This difference can make orbit valves better suited to repeated severe isolation service where seat wear is a concern.<br data-start=\"31890\" data-end=\"31893\" \/><strong data-start=\"31893\" data-end=\"31913\">Internal prompt:<\/strong> Review the Orbit Valve vs Ball Valve comparison above.<\/p>\n<h3 data-section-id=\"1i0ti86\" data-start=\"31970\" data-end=\"32021\"><span class=\"ez-toc-section\" id=\"What_does_an_orbit_valve_parts_diagram_include\"><\/span>What does an orbit valve parts diagram include?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"32023\" data-end=\"32329\">A proper orbit valve parts diagram should show the body, bonnet, stem, core, seat, packing, guide mechanism, bearings, and actuator interface. This helps engineers understand operation, maintenance, and replacement support requirements.<br data-start=\"32259\" data-end=\"32262\" \/><strong data-start=\"32262\" data-end=\"32282\">Internal prompt:<\/strong> See the parts and compatibility section above.<\/p>\n<h3 data-section-id=\"t7llf3\" data-start=\"32331\" data-end=\"32401\"><span class=\"ez-toc-section\" id=\"Why_are_orbit_valves_more_expensive_than_conventional_ball_valves\"><\/span>Why are orbit valves more expensive than conventional ball valves?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"32403\" data-end=\"32817\">Orbit valves use a more complex guided rising-stem shutoff mechanism and are typically evaluated for severe-service applications rather than commodity isolation duty. The higher initial cost is often justified when the application places more value on shutoff consistency, reduced seat wear, and longer maintenance intervals.<br data-start=\"32728\" data-end=\"32731\" \/><strong data-start=\"32731\" data-end=\"32751\">Internal prompt:<\/strong> Review the quick selection guide in the comparison section above.<\/p>\n<h3 data-section-id=\"12c7h0b\" data-start=\"32819\" data-end=\"32872\"><span class=\"ez-toc-section\" id=\"Are_orbit_valves_available_with_fire-safe_design\"><\/span>Are orbit valves available with fire-safe design?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"32874\" data-end=\"33166\">They can be reviewed with fire-safe design options where the project requires them. Fire-safe expectations should be stated clearly during RFQ so the quotation and documentation scope align with the project specification.<br data-start=\"33095\" data-end=\"33098\" \/><strong data-start=\"33098\" data-end=\"33118\">Internal prompt:<\/strong> See the standards and compliance section above.<\/p>\n<h3 data-section-id=\"16wdqql\" data-start=\"33168\" data-end=\"33235\"><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_an_orbit_valve_and_a_gate_valve\"><\/span>What is the difference between an orbit valve and a gate valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"33237\" data-end=\"33550\">A gate valve uses a linear gate movement, while an orbit valve uses a guided lift-and-turn motion. Orbit valves are typically considered where repeated severe isolation duty and non-rubbing shutoff logic are more important than commodity shutoff design.<br data-start=\"33490\" data-end=\"33493\" \/><strong data-start=\"33493\" data-end=\"33513\">Internal prompt:<\/strong> Review the comparison section above.<\/p>\n<h3 data-section-id=\"42961d\" data-start=\"33552\" data-end=\"33608\"><span class=\"ez-toc-section\" id=\"Can_orbit_valves_be_supplied_with_replacement_parts\"><\/span>Can orbit valves be supplied with replacement parts?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"33610\" data-end=\"33906\">Replacement support can be reviewed for seats, packing, gaskets, and other maintenance-related components based on the installed valve data. Nameplate information, photos, and drawings help improve review accuracy.<br data-start=\"33824\" data-end=\"33827\" \/><strong data-start=\"33827\" data-end=\"33847\">Internal prompt:<\/strong> See the replacement parts and compatibility section above.<\/p>\n<h3 data-section-id=\"qiicv7\" data-start=\"33908\" data-end=\"33978\"><span class=\"ez-toc-section\" id=\"What_documents_should_be_requested_before_ordering_an_orbit_valve\"><\/span>What documents should be requested before ordering an orbit valve?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"33980\" data-end=\"34312\">Buyers should usually confirm the technical datasheet, GA drawing, material certificates, testing records, and IOM requirements before order finalization. In project procurement, document delays often create bigger approval problems than fabrication itself.<br data-start=\"34237\" data-end=\"34240\" \/><strong data-start=\"34240\" data-end=\"34260\">Internal prompt:<\/strong> Review the purchaser documentation checklist above.<\/p>\n<h3 data-section-id=\"5y73bn\" data-start=\"34314\" data-end=\"34356\"><span class=\"ez-toc-section\" id=\"Where_are_orbit_valves_typically_used\"><\/span>Where are orbit valves typically used?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p data-start=\"34358\" data-end=\"34680\">Orbit valves are commonly reviewed for gas isolation, molecular sieve dryer switching, meter isolation, ESD-related shutoff duty, and other critical block service where shutoff reliability is a priority.<\/p>\n<p data-start=\"34358\" data-end=\"34680\"><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is an orbit valve?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"An orbit valve is a severe-service isolation valve that uses a rising stem lift-and-turn mechanism to open and close without the sealing surfaces rubbing during rotation. It is typically selected where shutoff reliability and lower seat wear matter in repeated service.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why is an orbit valve called a rising stem ball valve?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It is called a rising stem ball valve because the closure element lifts away from the seat before rotating. That rising motion separates the sealing surfaces first, helping reduce abrasion compared with a conventional ball valve.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between an orbit valve and a ball valve?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A conventional ball valve rotates against the seats during operation, while an orbit valve lifts the core away from the seat before rotation. This makes orbit valves better suited to repeated severe isolation service where seat wear is a concern.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does an orbit valve parts diagram include?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A proper orbit valve parts diagram should show the body, bonnet, stem, core, seat, packing, guide mechanism, bearings, and actuator interface. This helps engineers understand operation, maintenance, and replacement support requirements.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why are orbit valves more expensive than conventional ball valves?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Orbit valves use a more complex guided rising-stem shutoff mechanism and are usually selected for severe-service applications rather than commodity isolation duty. The higher initial cost is often justified when the application values shutoff consistency, reduced seat wear, and longer maintenance intervals.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Are orbit valves available with fire-safe design?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Orbit valves can be reviewed with fire-safe design options where the project requires them. Fire-safe expectations should be stated clearly during RFQ so the quotation and documentation scope align with the project specification.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between an orbit valve and a gate valve?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A gate valve uses a linear gate movement, while an orbit valve uses a guided lift-and-turn motion. Orbit valves are typically considered where repeated severe isolation duty and non-rubbing shutoff logic are more important than commodity shutoff design.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can orbit valves be supplied with replacement parts?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Replacement support can be reviewed for seats, packing, gaskets, and other maintenance-related components based on the installed valve data. Nameplate information, photos, and drawings help improve review accuracy.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What documents should be requested before ordering an orbit valve?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Buyers should usually confirm the technical datasheet, GA drawing, material certificates, testing records, and IOM requirements before order finalization. In project procurement, document delays often create bigger approval problems than fabrication itself.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Where are orbit valves typically used?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Orbit valves are commonly reviewed for gas isolation, molecular sieve dryer switching, meter isolation, ESD-related shutoff duty, and other critical block service where shutoff reliability is a priority.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<hr data-start=\"34682\" data-end=\"34685\" \/>\n<h2 data-section-id=\"1tqcpam\" data-start=\"34687\" data-end=\"34734\"><span class=\"ez-toc-section\" id=\"Request_Support_for_Your_Orbit_Valve_Project\"><\/span>Request Support for Your Orbit Valve Project<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"34736\" data-end=\"34911\">If you are evaluating an orbit rising stem ball valve for a new project, replacement requirement, or document review, the fastest next step is to send the key project details:<\/p>\n<ul data-start=\"34913\" data-end=\"35091\">\n<li data-section-id=\"2331fs\" data-start=\"34913\" data-end=\"34929\">\n<p data-start=\"34915\" data-end=\"34929\">service medium<\/p>\n<\/li>\n<li data-section-id=\"njohet\" data-start=\"34930\" data-end=\"34942\">\n<p data-start=\"34932\" data-end=\"34942\">valve size<\/p>\n<\/li>\n<li data-section-id=\"ch03cz\" data-start=\"34943\" data-end=\"34959\">\n<p data-start=\"34945\" data-end=\"34959\">pressure class<\/p>\n<\/li>\n<li data-section-id=\"1uzz517\" data-start=\"34960\" data-end=\"34979\">\n<p data-start=\"34962\" data-end=\"34979\">temperature range<\/p>\n<\/li>\n<li data-section-id=\"1fmj3n5\" data-start=\"34980\" data-end=\"34996\">\n<p data-start=\"34982\" data-end=\"34996\">end connection<\/p>\n<\/li>\n<li data-section-id=\"1xqtmku\" data-start=\"34997\" data-end=\"35013\">\n<p data-start=\"34999\" data-end=\"35013\">actuation type<\/p>\n<\/li>\n<li data-section-id=\"ynloa1\" data-start=\"35014\" data-end=\"35034\">\n<p data-start=\"35016\" data-end=\"35034\">required standards<\/p>\n<\/li>\n<li data-section-id=\"1ml829p\" data-start=\"35035\" data-end=\"35055\">\n<p data-start=\"35037\" data-end=\"35055\">required documents<\/p>\n<\/li>\n<li data-section-id=\"acrjp2\" data-start=\"35056\" data-end=\"35091\">\n<p data-start=\"35058\" data-end=\"35091\">replacement or new project status<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"35093\" data-end=\"35244\">\u00a0Tap to <a href=\"https:\/\/ntgdvalve.com\/contact-us\/\">Request a Quote<\/a> !<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u203b \u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432: 2\u2033-20\u2033<br \/>\n\u203b \u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043a\u043b\u0430\u0441\u0441\u043e\u0432: ANSI 150LB\/ 300LB\/600LB\/PN16\/ PN40<br \/>\n\u203b \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f: ASME B16.34; DIN 3202<br \/>\n\u203b \u0422\u043e\u0440\u0446\u0435\u0432\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435: \u0424\u043b\u0430\u043d\u0446\u0435\u0432\u043e\u0435; BW; \u0420\u0435\u0437\u044c\u0431\u0430<br \/>\n\u203b \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u043e\u0440\u0431\u0438\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043b\u0430\u043f\u0430\u043d\u043e\u0432<\/p>","protected":false},"featured_media":6524,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_eb_attr":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[96],"product_tag":[],"class_list":["post-4753","product","type-product","status-publish","has-post-thumbnail","product_cat-ball-valve","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/product\/4753","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/comments?post=4753"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/media\/6524"}],"wp:attachment":[{"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/media?parent=4753"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/product_brand?post=4753"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/product_cat?post=4753"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ntgdvalve.com\/ru\/wp-json\/wp\/v2\/product_tag?post=4753"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}